• 100 kVA Single Phase Pole Mounted Transformer
100 kVA Single Phase Pole Mounted Transformer
discuss personally
Model
DR11-100/10
Basic info
Brand Vziman
Model NO. 100 kva Single Phase Pole Mounted Transformer
Rated capacity 100kVA
Series Single Phase Pole Mounted Transformer
Product Detail

Product Overview

A professional distribution transformer manufacturer with 10 years of expertise, specializes in single-phase pole-mounted transformers for urban and rural power distribution. Designed for 11kV, 12.4kV, 13.2kV, 13.8kV, and 34.5kV input voltages, these transformers deliver outputs such as 240/480V and 120/240V, complying with IEEE C57, ANSI C57, and IEC 60076 standards.

Leading Technological Advantages

  • Enhanced Lightning Resistance: Unique winding technology minimizes surge damage.

  • Superior Mechanical Strength: Low magnetic leakage design with 45° full-oblique step-laminated iron core structure resists short circuits.

Shell & Construction

Precision Manufacturing:

  • Mitsubishi laser cutting and CNC punching ensure mm-level accuracy.

  • ABB robotic welding with laser detection achieves a 99.99998% leak-proof rate.

  • Durable Coating: Electrostatic spray paint offers 50+ years of corrosion resistance (100h salt spray test, hardness ≥0.4).

  • Fully Sealed Design: Cylindrical structure with self-sealing manual pressure relief valve (ANSI-compliant), NEMA-standard hanger brackets, and 30+ year maintenance-free operation.

Core Components

Iron Core

  • High-quality cold-rolled grain-oriented silicon steel sheets from Baowu Steel (China), with mineral oxide insulation.

  • Precision cutting and stacking reduce no-load current, losses, and noise.

Windings

  • Low Voltage: High-grade cable paper-wrapped wires.

  • High Voltage: Polyurethane enamelled round copper wires.

  • Interlayer insulation with dot-adhesive paper ensures coil stability and insulation resistance.

Premium Materials

  • Silicon steel sheets: Baowu Steel Group.

  • Oxygen-free copper: Chinese high-purity grade.

  • Transformer oil: CNPC Kunlun 25# premium oil.

Additional Features

  • High-strength polymer or porcelain low/high-voltage bushings.

  • Ring-type full-copper tinned terminals.

  • Integrated current-limiting fuses and arresters for surge protection.

Product parameters:

  • Capacity: 100kVA 

  • Rated voltage: 13.8kV, 34.5kV

  • Maximum operating voltage (kV) 38.5kV

  • Conditions of use:

  • The temperature:
    Maximum daily temperature (℃) : 40; Minimum daily temperature (℃) : -25; Maximum daily temperature difference (K) : 25; Average temperature of the hottest month (℃) : 30; Maximum annual average temperature (℃) : 20; Average daily relative humidity (≤%) : 95; Average monthly relative humidity (≤%) : 90 

  • Altitude (≤m) : 1000

  • Solar radiation intensity (W/cm2) : 0.1

  • Maximum ice thickness (mm) : 10

  • 10m high from the ground, maintain 10min average maximum wind speed (m/s) : 35

  • Ground horizontal acceleration (M/S2) : 2

  • Installation place: outdoor; 8. Pollution grade: ⅲ

image.png

Ordering instructions:

  • Main parameters of transformer (voltage, capacity, loss and other main parameters) .

  • Transformer use environment (altitude, temperature, humidity, place, etc) .

  • Other customized requirements (tap switch, color, oil pillow, etc) .

  • The minimum order quantity is 1 set, global delivery within 7 days .

  •  The normal delivery period is 30 days, with fast delivery worldwide .

What are the advantages of a single-phase pole-mounted transformer?

  • High Efficiency:Utilizes premium winding materials and advanced manufacturing techniques to achieve superior energy conversion efficiency, reducing operational losses.

  • Low Loss Performance:Constructed with high-grade silicon steel sheets and precision processes, minimizing no-load and load losses for enhanced energy savings and environmental friendliness.

  • Extended Service Life:Premium materials and rigorous manufacturing standards ensure prolonged durability, reducing replacement needs over the product lifecycle.

  • Low Noise Operation:Optimized core and coil design significantly reduces operational noise, making it ideal for noise-sensitive environments like urban areas or commercial buildings.

  • Reliable Performance:Oil-immersed design offers excellent cooling and insulation capabilities, ensuring stable operation in high-power, high-voltage applications.

  • Enhanced Fire Safety:Despite oil-based insulation, modern designs incorporate multi-layer protective measures (e.g., pressure relief valves, fire-retardant coatings) to mitigate risks.

  • Robust Environmental Adaptability:Engineered to withstand harsh conditions, including extreme temperatures, high humidity, and rugged terrain, for versatile deployment.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
What are the typical connection methods for 35kV distribution lines?
What are the typical connection methods for 35kV distribution lines?
Typical Wiring Diagram of 35kV Line Radial π ConnectionWhen a 35kV line adopts a radial power grid structure, a single - side power supply or a double - side power supply radial type can be used according to the situation of the power supply points, and a loop - out interval is reserved at the end of the line.Typical Wiring Diagram of 35kV Line Radial T - ConnectionFor double - radial lines, it is advisable to select a double - side power supply. When the power supply points do not meet the r
Leon
07/18/2025
Why are the ground fault point and the accident point not at the same location?
Why are the ground fault point and the accident point not at the same location?
Fault Transfer VoltageIn low - voltage distribution systems, there is a type of personal electric shock accident where the accident occurrence point and the system fault point are not at the same location. This kind of accident occurs because after a ground fault happens elsewhere, the generated fault voltage is conducted to the metal casings of other equipment through the PE wire or PEN wire. When the fault voltage on the metal casing of the equipment is higher than the human - body safe voltag
Leon
07/18/2025
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!