| Brand | Wone Store |
| Model NO. | 10-30kW Single-phase OFF-Grid Wind&Solar Hybrid Controller |
| Rated Output Rating | 10kW |
| Input Voltage | DC240V |
| Series | WIS |
Features
Can be applied in wind, solar, wind&solar hybrid power generation system
Simple structure, complete function
Lowno-load loss byusing industrial frequency transformer
R5232/R5485/GPRS optional (Those with GPR5 can also be monitored through App.
CE certification
Applications
Application in wind, Solar, Wind&Solar hybrid power generation station.
Application in household wind&solar hybrid power generation system.
Power supply for those unmanned regions like the coastal islands, remote mountainous regions and border posts.
Technology Parameters
Technical Parameters |
W100 - 96 |
W100 - 120 |
W100 - 240 |
W200 - 240 |
W300 - 240 |
DC Input Parameters |
|||||
Rated battery voltage |
96VDC |
120VDC |
240VDC |
240VDC |
240VDC |
Input overvoltage point |
136VDC |
170VDC |
340VDC |
340VDC |
340VDC |
Input overvoltage recovery point |
132VDC |
165VDC |
330VDC |
330VDC |
330VDC |
Input undervoltage point |
86.4 VDC |
108VDC |
216VDC |
216VDC |
216VDC |
Input undervoltage recovery point |
96VDC |
120VDC |
240VDC |
240VDC |
240VDC |
AC Output Parameters |
|||||
Output phase number |
Single phase |
||||
Rated output power |
10kW |
10kW |
10kW |
20kW |
30kW |
Rated output voltage |
110/120/220/230/240VAC |
||||
Rated output frequency |
50/60±0.5Hz |
||||
THDi |
<5% |
||||
Efficiency |
|||||
Max. conversion efficiency |
≥85% |
||||
Protection Functions |
|||||
DC input overvoltage protection |
YES |
||||
DC reversed connection protection |
YES |
||||
AC output overload protection |
YES |
||||
AC short circuit protection |
YES |
||||
Surge protection |
YES |
||||
Over - temperature protection |
YES |
||||
General Parameters |
|||||
Display mode |
LCD |
||||
Display information |
Battery voltage, inverter voltage, inverter current, inverter power, and working status of battery overvoltage/undervoltage and AC output overload/short circuit. |
||||
Monitoring mode(optional) |
RS232/RS485/GPRS |
||||
Monitoring Contents
|
Real-time display: Battery voltage, inverter voltage,inverter current, inverter power, and working status of battery overvoltage/undervoltage and AC output overload/short circuit. |
||||
Parameter setting: overvoltage point, overvoltage recovery point, undervoltage point, and undervoltage recovery point. |
|||||
Isolation mode |
Industrial frequency isolation |
||||
No-load current |
≤1.5A |
≤1.5A |
≤1.5A |
≤1.5A |
≤1.5A |
Environment |
|||||
Temperature |
-20℃~+40℃ |
||||
Humidity |
5%~95%, No condensing |
||||
Noise |
<60dB |
||||
Cooling mode |
Forced air cooling |
||||
Cover protection class |
IP20 |
||||
Product |
|||||
Product dimension(W*H*D) |
500x725x500mm |
600x1180x600mm |
|||
Product net weight |
75kg |
200kg |
260kg |
||
Note: Part of parameters can be adjusted according to customer's specific demand. |
|||||