Wat is die ontwerp- en toepassingsaspekte van die 10KV voeder outomatiese spanningregelaar?

Dyson
Dyson
Veld: Elektriese Standaarde
China

Na die herstel van die landelike kragleidingnetwerk het die landelike verspreidingsnetwerk beskryfbaar verbeter. Owing to constraints like terrain, landscape, and investment scale, is the layout egter nie optimal nie. As gevolg hiervan oorskry die kragverskaffingsradius van sommige 10 kV oorspanningslyne die redelike bereik. Met die verandering van seisoene en dag en nag, is daar beduidende spanningsfluktuasies, wat lei tot probleme soos onstandaard kragkwaliteit en relatief hoë lynverliesse, wat boerderye se lewens en produksie ernstig beïnvloed. Daarom ontwerp hierdie artikel 'n nuut-tipe spanningsreguleerder: die voederlyn outomatiese spanningsreguleerder.

1 Werkprinsipe van die Spanningsreguleerder

'n Outomatiese spanningsreguleerder is 'n toestel wat outomaties veranderinge in die insetspanning volg om 'n stabiele uitsetspanning te verseker. Dit kan wyd gebruik word in 6 kV, 10 kV, en 35 kV kragverskaffingstelsels, en kan die insetspanning binne 'n 20% bereik outomaties aanpas. Die installasie van die toestel op 1/2 of 2/3 van die afstand vanaf die begin van die lyn kan die spanningskwaliteit van die lyn verseker.

Vir transformatorhokke waar die hooftransformator nie op-lading spanningsaanpassing vermoë het nie, kan die outomatiese spanningsreguleerder ook op die uitgaande lynkant van die hooftransformator van die transformatorhok geïnstalleer word om op-lading spanningsaanpassing te bewerkstellig. Daar is verskeie tappings op die sekondêre kant van die transformator. Deur 'n enkelchip mikrorekenaar te gebruik om die aan-af van thyristors te beheer, word verskillende vlakke van spanningsaanpassing verskaf, en dus die doel van voederlyn spanningsaanpassing bereik.

2 Instelling van die Spanningsreguleerder se Tapping-wisseling Aksie-spanning

Die voederlyn spanningsreguleerder kan tappings volgens verskillende belastingstoestande aanpas en die transformasieverhouding gebaseer op die lynspanning aanpas om spanningsaanpassing te bewerkstellig. Dit het 7 tappings en 'n 30% spanningsaanpassingsbereik, wat dit goed laat voldoen aan die landelike spanningsaanpassingsvereistes.

2.1 Prinsipe van die Instelling van die Spanningsreguleerder se Tapping-wisseling Spanning

Owing to load fluctuations, will the voltage at the end of the line change. For different voltage drops, it is necessary to adjust the tap settings of the voltage regulator. Figure 1 depicts a typical rural transmission power grid. Here, the line length is set as L km, and the power at the end of the line is set as S = P + jQ MVA.

 

Requirements for gear shifting: Ensure that the voltage at the end of the line varies within a 7% range; generally, gear skipping is not allowed; the number of gear shifts should be as few as possible.

Assume the transformation ratio is K, the voltage at the beginning of the line is U0, the voltage at the end of the line is U1, the input voltage of the voltage regulator is Uin, and the output voltage is Uout, with Uout=KUin.

According to the model, the following equation holds:U1=Uout−ΔU1.

Where Δ U1 is the voltage drop from the installation point of the voltage regulator to the end of the line, and x is the distance from the installation point of the voltage regulator to the beginning of the line. It follows that:

(U0 - Uin) is the voltage drop from the beginning of the line to the installation point.α = U0/Uout is the line voltage level ratio before and after the installation point of the voltage regulator. Let (L−x)/x=K1, and substituting it in, we get:

Among them, the voltage U1at the end of the line needs to satisfy the constraint condition 9.7 < U1 < 10.7. Substituting it into the above formula, the range of Uin under the condition that K is known can be obtained. However, obviously, due to the existence of U0/Uout, it is necessary to solve a quadratic equation of one variable, and there will be the problem of spurious roots. The paper simplifies this equation.

For the analysis of &alpha;=U0/ Uout, Uout and U1 have the same increasing or decreasing trend. U0 is a constant, so &alpha;=U0/ Uout, Uout is inversely proportional to U1. It can also be analyzed that when U1 = 9.3, &alpha;&asymp;1; and when U1=10.7,&alpha; is slightly less than 1. Therefore, the constraint equation can be written as:

That is:

2.2 Setting Example

As can be seen from Formula (5), in fact, the setting of the gear-shifting action only relates to the input voltage Uin of the voltage regulator and the ratio Kt of the distance from the voltage regulator installation point to the line length. There is no need to measure the actual load at the end of the line, which greatly simplifies the difficulty of actual engineering.

Take a certain actual transmission line as an example. Still use the model shown in Figure 1. The length of the transmission line is 20 km. The voltage regulator is usually installed in the middle of the line. Here, the distance from the start of the line is taken as x = 9, km, and Kt = 11/9. Substitute into Formula (5), and we can get:

For a certain gear position, the input voltage range that satisfies the quality requirements of the electric energy at the end has upper and lower limits, which are the operating voltages (shift voltages) for that gear. Each gear has its corresponding operating voltage, and this relationship can be more intuitively seen on the number axis.

Among them, Gear 1 is left unused because under normal conditions, the input voltage will not exceed the upper limit of this gear. Gear 1 can be used as a special operating condition, such as fault-tolerant operation during a single-phase ground short circuit. The following describes the switching conditions when the gear reaches the action voltage:

It should be noted that when down-shifting from gear 4, it directly shifts down to gear 2. This is because the lower action limits of gear 3 and gear 4 are relatively close. If the voltage changes greatly, after shifting down from gear 4 to gear 3, it may be necessary to immediately shift down to gear 2, which increases the number of actions. Therefore, to reduce the number of actions, cross-gear shifting is allowed.

3 Design of the Gear-shifting Controller

Currently, the commonly adopted gear-shifting method is to use a motor to drive the movement of the gear switch blade. However, how to ensure the rapid and accurate rotation of the motor has always been a problem. To achieve a better control effect, this paper adopts a thyristor control system.

3.1 Thyristor Control Principle

Thyristors can be used to realize the control of high-power circuits with weak currents. The feeder voltage regulator uses 7 pairs of bidirectional thyristors to control the gears, as shown in Figure 2. Each pair of thyristors is connected to different windings of the transformer, thus corresponding to different transformation ratios.

3.2 Design of Single-chip Microcomputer Gear-shifting Controller

The control of bidirectional thyristors only requires voltage driving from TTL gate circuits and can be directly connected to the output port of the single-chip microcomputer. To save output ports, only 3 ports are used, and an external 3-to-8 decoder is connected to drive the control of 7 gear positions, as shown in Figure 3.

4 Design of the Intelligent Control System

For a voltage regulator with a control chip, having only the automatic voltage regulation function is insufficient, and it also fails to fully utilize the performance of the single-chip microcomputer. A complete control system, as shown in Figure 4, also includes keyboard input, a display circuit, wireless communication, an external clock, external storage, and fault protection.

Keyboard input enables program adjustment, wireless communication allows real-time monitoring of the voltage regulator's operation. The external clock ensures time recording during single-chip microcomputer power failure. External storage safely stores massive system operation data for future research. Fault protection makes the single-chip microcomputer enter a special operation mode under abnormal conditions to meet power transmission tasks, protects it from damage under faults, and cooperates with relay protection devices to safeguard transmission lines.

5 Conclusion

By building a transmission line model and conducting load flow calculations, the setting rules for the voltage regulator gear action voltage are determined. For transformer tap control, traditional mechanical control is replaced with more convenient and faster thyristor control, featuring simple design and good control effect. The feeder automatic voltage regulator has a wide voltage regulation range, effectively ensuring the voltage quality of transmission lines.

Gee 'n fooitjie en moedig die outeur aan!
Aanbevole
Minimum Betrykspanning vir Vakuum-sirkuitsnarrers
Minimum Betrykspanning vir Vakuum-sirkuitsnarrers
Minimum Betryksvoltage vir Trip- en Close-operasies in Vakuumkringbrekers1. InleidingWanneer jy die term "vakuumkringbreker" hoor, kan dit onbekend klink. Maar as ons sê "kringbreker" of "kragskakelaar," sal die meeste mense weet wat dit beteken. In werklikheid is vakuumkringbrekers sleutelkomponente in moderne kragstelsels, verantwoordelik vir die beskerming van kringe teen skade. Vandag gaan ons 'n belangrike konsep ondersoek — die minimum betryksvoltage vir trip- en close-operasies.Alhoewel d
Dyson
10/18/2025
Effektiewe Wind-PV Hibrïde Stelsel Optimering met Opslag
Effektiewe Wind-PV Hibrïde Stelsel Optimering met Opslag
1. Analise van Wind- en Son-PV Kragopwekken KarakteristiekeDie analise van die karakteristieke van wind- en son-pv (PV) kragopwekking is fundamenteel vir die ontwerp van 'n komplementêre hibriede stelsel. Statistiese analise van jaarlikse windspoed- en sonbestralingsdata vir 'n spesifieke gebied toon dat windhulpbronne seisoenale variasies vertoon, met hoër windspeeds in winter en lente en laer spoede in somer en herfs. Windkragopwekking is eweredig aan die derde mag van windspeed, wat tot bedui
Dyson
10/15/2025
Wind-Sonne Hybride Gestragte IoT-stelsel vir Real-time Waterleidingemonitoring
Wind-Sonne Hybride Gestragte IoT-stelsel vir Real-time Waterleidingemonitoring
I. Huidige Status en Bestaande ProblemeTans het watervoorsieningsmaatskappye uitgebreide netwerke van waterleidings wat ondergronds oor stedelike en landelike areas gelei is. Real-time monitering van leidingbedryfsdata is essensieel vir doeltreffende bevelvoering en beheer van waterproduksie en -verspreiding. Daarom moet talryke datamoniteringsstasies langs die leidings opgerig word. Tog is stabiele en betroubare kragbronne naby hierdie leidings selde beskikbaar. Selfs wanneer krag beskikbaar is
Dyson
10/14/2025
Hoe om 'n AGV-gebaseerde intelligente skuurstelsel te bou
Hoe om 'n AGV-gebaseerde intelligente skuurstelsel te bou
AGV-gebaseerde intelligente magazynlogistieke stelselMet die vinnige ontwikkeling van die logistieke industrie, toenemende grondskarsiteit en stygende arbeidskoste, staan magazyns, as sleutellogistieke knoppunte, voor betekenisvolle uitdagings. As magazyns groter word, neem operasie-frekwensies toe, groei inligtingskomplikasie en word bestellingsverwerking meer veeënd, het die bereiking van lae foutkoerse, verlaagde arbeidskoste en verbeterde algehele opbergdoeltreffendheid 'n primêre doelwit vi
Dyson
10/08/2025
Stuur navraag
Laai af
Kry die IEE-Business-toepassing
Gebruik die IEE-Business app om toerusting te vind kry oplossings verbind met kenners en neem deel aan bedryfsamenwerking waar en wanneer ook al volledig ondersteunend van jou kragprojekte en besigheidsgroei