Reactor Electricus: Quid Sunt? (Reactores Lineares)

Electrical4u
Campus: Electrica Elementaria
0
China

Quid est Reactor Electricus

Quid est Reactor Lineae

Reactor lineae (vel reactor electricus sive chokes) est accessorium variabilis frequentialis drive (VFD) quod constat spira fili quae format agmen magneticum ut currens per eam transit. Hoc agmen magneticum limitat celeritatem ascensionis currens, ita reducens harmonicos et protegens drive ab impulsum systematis electrici et transientibus.

Species Reactorum Electricorum vel Lineae

Reactor multas partes in systemate electrico potest gerere. Reactores normaliter secundum modos applicationis classificantur. Sicut:

  1. Reactor Shunt

  2. Reactor Limitans Currens et Neutralis Territorialis

  3. Reactor Dampens

  4. Reactor Tuning

  5. Transformator Territorialis

  6. Reactor Suppression Arcus

  7. Reactor Smoothing etc.

Ex puncto constructionis, reactores classificantur ut:

  1. Reactor Nuclei Aëris

  2. Reactor Nuclei Ferri Gapped

Ex puncto operationis, reactores classificantur ut:

  1. Reactor Variabilis

  2. Reactor Fixus.

Praeterea, reactor etiam classificari potest ut:

  1. Typus Internus vel

  2. Typus Externus Reactor.



reactor electricus



Reactor Shunt

Hic reactor normaliter in parallelo in systema connectitur. Propositum normalis reactoris shunt est compensare componentem capacitive currentis in systema. Id est hunc reactor principali modo ad absorbendum VAR (potentia reactiva) generatum ex effectu capacitivo systematis usum.

In substatione, reactores shunt normaliter inter lineam et terram connectuntur. VAR absorbens a reactor potest esse fixum vel variabile secundum requirementum systematis. Variatio VAR in reactor potest obtineri per usum thyristorum phase control aut per magnetizandum nucleum ferri DC. Haec variatio etiam potest obtineri per commutatorem tap offline vel online associatum cum reactor.

Reactor shunt potest esse vel uniphasis vel triphasica secundum configurationem systematis electrici. Reactor shunt potest esse vel nucleo aëris vel nucleo ferri gapped secundum feature designandi. Hic etiam magnetic shielded vel sine magnetic shield. Reactores shunt etiam possunt designari cum winding additionali pro supplendo potenti auxiliari systemati.

Reactor Series

Reactor Limitans Currens est genus Reactoris Series. Reactores Series in systema in serie connectuntur. Normaliter ad limitandam fault current in systema vel ad facilitandam propriam partem oneris in network parallel power usus sunt. Quando reactor series cum alternatore connectitur, referimus eum ad Generator Line Reactor. Hoc est ut minuamus stressus tempore fault circuitus triplicis phase.

Reactor series etiam in serie in feeder vel bus electrico connecti potest ut minimizet effectum fault circuitus in aliis partibus systematis. Effectu fault current in illa parte systematis limitata, fault current withstand rating equipment et conductors illius partis systematis potest esse minor. Hoc facit systema cost-effective.

Cum reactor de ratione conveniente inter neutralis et terram connectionem systematis connectatur, ad limitandam lineam ad terram currentem durante fault in systema, dicitur Neutral Earthing Reactor.

Cum capacitor bank switch on in conditione non carica, potest esse inrush current magnus per eam fluens. Ut limitet hunc inrush current, reactor in serie cum unaquaque phase capacitor bank connectitur. Reactor ad hoc usus cognoscitur ut damping reactor. Hic dampit transient condition of the capacitor. Etiam ad suppressendos harmonicos presentes in systema iuvat. Hi reactores typice rateantur cum suo maximo inrush current addito ad suam capacitate portandi currens continue.

Wave trap in serie cum feeder line connectus est genus reactor. Hic reactor cum Coupling Capacitor lineae creant circuitum filter ad bloccandas frequentias praeter frequentiam potenti. Huiusmodi reactor principaliter ad facilitandum Power Line Carrier Communication usus est. Hic dicitur Tuning Reactor. Quia ad creandum circuitum filter usus est, etiam dicitur filter reactor. Vulgo et populariter cognoscitur ut Wave Trap.

In systemate delta connected, punctum stellare vel neutral point creatur per usum zigzag star connected 3 phase reactor, dictus earthing transformer. Hic reactor potest habere winding secundarium ad obtinendum potentiam pro supply auxiliaris substation. Propter hoc hic reactor etiam dicitur earthing transformer.

Reactor connectus inter neutralis et terram ad limitandam single phase ad terram fault current dicitur Arc Suppression Reactor.

Reactor etiam ad filtrandos harmonicos presentes in DC power usus est. Reactor in DC power network ad hoc usus dicitur smoothing reactor.

Declaratio: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Donum da et auctorem hortare

Suggestus

Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
02/05/2026
Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
01/30/2026
Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
01/29/2026
Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
01/29/2026
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum