What is the purpose of grounding the neutral wire? How does grounding differ from bonding in terms of safety?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Purpose of neutral grounding

Provide reference potential

In a power system, neutral grounding provides a stable reference potential for the entire circuit, which is usually defined as zero potential. This helps determine the voltage value of other lines (such as the fireline) with respect to this zero potential, making voltage measurement and analysis more convenient and accurate. For example, in a three-phase four-wire low-voltage distribution system (380V/220V), the voltage between the live line and the neutral line is 220V, and this voltage value is determined based on the zero potential of the neutral line.

Ensure the stable operation of the system

For three-phase unbalanced load, neutral grounding can ensure the relative stability of three-phase voltage. When the three-phase load is unbalanced (for example, in some residential areas or small commercial power scenarios, the number and power of electrical equipment connected on different phases are different), the neutral line can direct the unbalanced current back to the neutral point of the power supply to avoid affecting the normal operation of the electrical equipment due to the three-phase voltage imbalance. If the neutral line is not grounded, the three-phase imbalance may cause the voltage of each phase to fluctuate greatly, affecting the service life of the device or even damaging the device.

Fault protection

In the event of a single-phase ground fault, neutral grounding helps the fault current flow quickly. For example, when a live wire is accidentally grounded, the grounded neutral line provides a low-impedance return path for the fault current, so that the protection device (such as fuses, circuit breakers, etc.) can detect the fault current in time and act to cut off the circuit, thus protecting personal safety and equipment safety.

Difference in safety between grounding and zero connection

Different protection principles

  • Grounding (protective grounding) : Protective grounding is the reliable connection between the metal shell or frame of the electrical equipment and the earth. When a leakage fault occurs in the equipment, such as the winding insulation of the motor is damaged so that the housing is charged, because the housing is grounded, the leakage current will flow into the earth through the grounding resistance. If the grounding resistance is small enough to make the grounding current reach the operating current threshold of the protection device (such as the leakage protector), the protection device will act to cut off the circuit; If the grounding resistance is large, although the protection device cannot be activated immediately, when the human body contacts the charged shell, because the human body resistance is much larger than the grounding resistance, most of the leakage current will flow into the earth through the grounding resistance, thereby reducing the current through the human body and reducing the risk of electric shock.

  • Zero connection (protective zero connection) : The protective zero connection is to connect the metal shell of the electrical equipment to the neutral line (neutral line). In the three-phase four-wire system, if the equipment leakage occurs, such as a fire line and the equipment housing short circuit, then the phase of the short circuit current will return to the power supply through the neutral line, the short circuit current is usually large, will quickly make the fuse on the line to fuse or circuit breaker trip, thus cutting off the power supply to prevent human shock.

Different scope of application

  • Grounding: Suitable for power systems with neutral points ungrounded or grounded by high impedance, such as simple distribution systems in some rural areas or some special industrial power systems. In these systems, because the effective fault protection cannot be realized through zero connection, grounding is an important means to ensure safety.

  • Zero connection: It is mainly suitable for three-phase four-wire low-voltage distribution system with direct grounding of neutral point (such as common 380V/220V system). In this kind of system, the neutral line has been grounded, and the leakage protection can be realized quickly and effectively by using the protective zero connection.

The voltage at the time of failure is different

  • Grounding: In a protective grounding system, when a leakage fault occurs in the device, the voltage to ground of the device housing is equal to the leakage current multiplied by the grounding resistance. If the grounding resistance is large, the device enclosure may carry a high voltage to the ground. Although the current passing through the human body is relatively small, there is still a risk of electric shock.

  • Zero connection: In the protective zero connection system, once the equipment leakage occurs, because the short-circuit current returns to the power supply through the neutral line, the theoretical voltage to the ground of the equipment housing will quickly drop to close to zero volts, greatly improving safety.

Give a tip and encourage the author!
Recommended
What are the safety precautions and guidelines for using AC load banks?
What are the safety precautions and guidelines for using AC load banks?
AC load banks are electrical devices used to simulate real-world loads and are widely applied in power systems, communication systems, automation control systems, and other fields. To ensure personal and equipment safety during use, the following safety precautions and guidelines must be observed:Select an appropriate AC load bank: Choose an AC load bank that meets actual requirements, ensuring its capacity, voltage rating, and other parameters satisfy the intended application. Additionally, sel
Echo
11/06/2025
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
Relay Protection Types in Substations: A Complete Guide
Relay Protection Types in Substations: A Complete Guide
(1) Generator Protection:Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Tripping actions include shutdown, islanding, limiting fault impact, and alarm signaling.(2) Transformer Protection:Power transformer protection includes: phase-to-phase short
Echo
11/05/2025