• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Three-Tier Power Distribution System in a Newly Constructed Residential Area

Rockwell
Rockwell
Field: Manufacturing
China

In a newly constructed residential area, a 10kV power line is introduced into the substation. After stepping down the voltage through the transformer's low-voltage side (0.4kV), power distribution is achieved through three levels of distribution boxes: the main distribution board, secondary distribution boards, and tertiary distribution boards.

Main Distribution Board

  • Serves as the primary distribution point for the entire project, directly connected to the transformer providing 0.4kV power.

  • Does not supply power directly to end-use equipment but acts as a centralized power distribution hub.

  • Includes components such as isolating switches, circuit breakers, and Residual Current Devices (RCDs) to ensure overall circuit safety.

Secondary Distribution Boards

  • Designed for specific buildings or floors, responsible for distributing three-phase power.

  • Connects to motors or other heavy loads, utilizing larger capacity three-phase circuit breakers to ensure safe operation.

  • Emphasizes protective measures like dual-door protection, durable coatings, and rainproof designs suitable for outdoor environments, ensuring electrical safety during the intermediate stages.

Tertiary Distribution Boards

  • Ultimately connects to home systems or specific pieces of equipment, supplying 220V single-phase power.

  • Implements strict safety standards, such as "one device, one circuit breaker, one RCD, one box," ensuring independent circuit protection for each device.

  • May include fixed or portable boxes to ensure electrical safety and adhere to a "two-layer protection" strategy, meaning RCDs at both the tertiary (device level) and secondary (area level).

This three-tier distribution system structure — with the main distribution board acting as the primary delivery point, secondary distribution boards serving as intermediate power hubs, and tertiary distribution boards directly supplying end-use equipment — ensures effective power management, high safety, and reliability in complex electrical systems, especially suited for the power needs of construction sites or large projects.

Give a tip and encourage the author!
Recommended
PT Fuse Slow Blow: Causes, Detection & Prevention
PT Fuse Slow Blow: Causes, Detection & Prevention
I. Fuse Structure and Root Cause AnalysisSlow Fuse Blowing:From the design principle of fuses, when a large fault current passes through the fuse element, due to the metal effect (certain refractory metals become fusible under specific alloy conditions), the fuse first melts at the soldered tin ball. The arc then rapidly vaporizes the entire fuse element. The resulting arc is quickly extinguished by quartz sand.However, due to harsh operating environments, the fuse element may age under the comb
Edwiin
10/24/2025
Why Fuses Blow: Overload, Short Circuit & Surge Causes
Why Fuses Blow: Overload, Short Circuit & Surge Causes
Common Causes of Fuse BlowingCommon reasons for fuse blowing include voltage fluctuations, short circuits, lightning strikes during storms, and current overloads. These conditions can easily cause the fuse element to melt.A fuse is an electrical device that interrupts the circuit by melting its fusible element due to heat generated when current exceeds a specified value. It operates on the principle that, after an overcurrent persists for a certain period, the heat produced by the current melts
Echo
10/24/2025
Fuse Maintenance & Replacement: Safety and Best Practices
Fuse Maintenance & Replacement: Safety and Best Practices
1. Fuse MaintenanceFuses in service should be regularly inspected. The inspection includes the following items: Load current should be compatible with the rated current of the fuse element. For fuses equipped with a fuse blown indicator, check whether the indicator has actuated. Check the conductors, connection points, and the fuse itself for overheating; ensure connections are tight and making good contact. Inspect the fuse exterior for cracks, contamination, or signs of arcing/discharge. Liste
James
10/24/2025
Maintenance and Repair Items for 10kV High-Voltage Switchgear
Maintenance and Repair Items for 10kV High-Voltage Switchgear
I. Routine Maintenance and Inspection(1) Visual Inspection of Switchgear Enclosure No deformation or physical damage to the enclosure. Protective paint coating shows no severe rust, peeling, or flaking. Cabinet is securely installed, clean on the surface, and free of foreign objects. Nameplates and identification labels are neatly affixed and not falling off.(2) Check of Switchgear Operating Parameters Instruments and meters indicate normal values (comparable to typical operating data, with no s
Edwiin
10/24/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.