Why is the star-delta starting method not possible for a delta connected induction motor?

Encyclopedia
11/05/2024

The reason why an induction motor with a delta-connected configuration cannot use the star-delta starting method mainly involves the electrical characteristics of the motor and the relationship between current and voltage during the starting process. Here is a detailed explanation:

Differences in Electrical Characteristics

Voltage Relationship

In a triangle (Δ) connection, the voltage on each winding is equal to the line voltage of the source.

In a star (Y) connection, the voltage on each winding is equal to the phase voltage of the source, which is approximately 1/√3 times the line voltage.

Current Relationships

When connected in a triangle, the line current is equal to the phase current.

When connected in a star configuration, the line current is equal to the phase current times the square root of 3.

Impacts during startup

Starting Current

If the original triangle-connected motor is changed to a star connection for starting, the phase voltage at startup will be reduced to about 1/√3 times, resulting in insufficient starting current to drive the motor to normal speed.

In this case, the motor may not start properly, and even if it does start, it may be damaged due to overload.

Insufficient Power

Due to the lower phase voltage in a star connection, the starting torque of the motor will also be significantly reduced, unable to provide sufficient torque to overcome the starting load.

Practical Application

In practical applications, star-delta starting is mainly used for motors that have lighter loads during startup and heavier loads during operation.

For a motor that has been designed for delta connection, changing the connection method will not only fail to bring about any starting advantage, but may also lead to starting failure or damage to the motor.

In summary, the induction motor with a delta-connected winding cannot use the star-delta starting method, mainly because this operation leads to insufficient starting current, inadequate starting torque, and potential motor overload and damage. The correct approach is to select an appropriate starting method based on the specific motor design and load characteristics.


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Abnormal Operating Condition and Causes of Induction Motors
Abnormal Operating Condition and Causes of Induction Motors
Abnormal Operating Conditions and Causes of Induction MotorsThree-phase induction motors are widely used in industrial applications. Their abnormal operating conditions and causes can be summarized as follows:Abnormal Operating Conditions and Causes of Induction MotorsThe following are the abnormal operating conditions and causes of induction motors:Mechanical OverloadBlockage in Pump/Gear Systems: Obstruction in mechanical systems (e.g., pumps or gears) connected to the motor.Damaged Bearings o
Edwiin
05/19/2025
Polarity Test of a Transformer – Circuit Diagram and Working
Polarity Test of a Transformer – Circuit Diagram and Working
Polarity in Two-Winding TransformersIn two-winding transformers, one terminal of a winding is always positive relative to the other at any instant. Transformer polarity refers to therelative direction of induced voltagesbetween the high-voltage (HV) and low-voltage (LV) windings. In practical transformers, winding terminals are brought out as leads, and polarity defines how these leads are connected and labeled.Significance of Transformer PolarityUnderstanding polarity is critical for several op
Edwiin
05/15/2025
Capacitor Start Induction Motor
Capacitor Start Induction Motor
Capacitor Start Motors are a type of single - phase induction motors. They utilize a capacitor within the auxiliary winding circuit to create a significant phase difference between the current flowing through the main winding and that in the auxiliary winding. As the name "capacitor start" clearly implies, these motors rely on a capacitor specifically for the starting process. The diagram below illustrates the connection schematic of a Capacitor Start Motor.The capacitor start motor features a c
Encyclopedia
05/09/2025
 Thermal Power Plant – Components, Working and Site Selection
Thermal Power Plant – Components, Working and Site Selection
What is a Thermal Power Plant?The law of energy conservation states that energy cannot be created or destroyed; rather, it can only be transformed from one form to another. Electrical energy, in particular, can be harnessed from a variety of energy sources. Facilities designed to generate large - scale electrical energy are commonly referred to as power plants or power stations.A thermal power plant is a type of power generation facility that converts heat energy into electrical energy. Heat ene
Encyclopedia
05/07/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!