بەکارهێنانی تاکنیکەکانی شلابڕەی نوری بۆ ڕاستەوخولدنی ئاینەڵایی پارامترەکانی کوپتانەرە سەرەکیەکانی هەژارەی نزم

Edwiin
Edwiin
qalab: گەڕانکاری بەرپێزی
China

Principles of Sensing

Principles of sensing involve detecting changes in the state of light polarization due to various physical phenomena. These include:

•    Pockels Effect: Changes in polarization caused by an electric field.
•    Faraday Effect: Changes in polarization caused by a magnetic field.
•    Photoelasticity: Changes in polarization due to mechanical stress.
•    Thermochromic Effects: Changes in light characteristics due to temperature variations.
•    Mechanical Vibration: Changes in the spatial distribution of light caused by mechanical vibrations.

High Voltage Gas Blast Interrupter with Optical Fiber Chromatic Sensors

The figure illustrates a schematic diagram of a high voltage gas blast interrupter, highlighting various types of optical fiber chromatic sensors deployed for monitoring different parameters. These sensors include:
•    Gas Pressure Sensors: Monitoring gas pressures in the interrupter tank and piston chamber using Fabry-Perot pressure sensors.
•    Contact Potential Sensors: Measuring the potential difference across contacts.
•    Fault Current Sensors: Detecting fault currents within the system.
•    Temperature Sensors: Monitoring the temperature of the contact stalk.
•    Contact Travel Sensors: Using chromatic linear scales to measure the movement of contacts.
•    Mechanical Vibration Sensors: Detecting vibrations during operation.
•    Arc Radiation Sensors: Monitoring radiation emitted by arcs during interruption.

Time Variation Data During Circuit Breaker Operation

The time variation data for key parameters during circuit breaker operation are as follows:

•    Piston Chamber Pressure: Measured using a Fabry-Perot pressure sensor.
•    Contact Travel: Monitored using a chromatic linear scale.
•    Mechanical Vibration: Detected during the breaker's operation.
These datasets provide valuable insights into the conditions that occur during the fault current interruption process. By analyzing this information together, a better understanding of the interrupter's operation can be achieved, leading to improved performance and reliability.

Translation and Polished Version

Principles of Sensing

Principles of sensing involve detecting changes in the state of light polarization due to various physical phenomena. These include:

•    Pockels Effect: Changes in polarization caused by an electric field.
•    Faraday Effect: Changes in polarization caused by a magnetic field.
•    Photoelasticity: Changes in polarization due to mechanical stress.
•    Thermochromic Effects: Changes in light characteristics due to temperature variations.
•    Mechanical Vibration: Changes in the spatial distribution of light caused by mechanical vibrations.

High Voltage Gas Blast Interrupter with Optical Fiber Chromatic Sensors

The figure shows a schematic diagram of a high voltage gas blast interrupter, indicating various types of optical fiber chromatic sensors that have been deployed. These sensors include:

•    Gas Pressure Sensors: Monitoring gas pressures in the interrupter tank and piston chamber using Fabry-Perot pressure sensors.
•    Contact Potential Sensors: Measuring the potential difference across contacts.
•    Fault Current Sensors: Detecting fault currents within the system.
•    Temperature Sensors: Monitoring the temperature of the contact stalk.
•    Contact Travel Sensors: Using chromatic linear scales to measure the movement of contacts.
•    Mechanical Vibration Sensors: Detecting vibrations during operation.
•    Arc Radiation Sensors: Monitoring radiation emitted by arcs during interruption.

Time Variation Data During Circuit Breaker Operation

The time variation data for key parameters during circuit breaker operation are as follows:

•    Piston Chamber Pressure: Measured using a Fabry-Perot pressure sensor.
•    Contact Travel: Monitored using a chromatic linear scale.
•    Mechanical Vibration: Detected during the breaker's operation.

Such data taken together provide insight into the various conditions that occur during the fault current interruption process, so that an improved understanding of the interrupter operation can be obtained.

Bexşişek bidin û nuşkarê wê bikevin!​
Pêşniyariyek
Davê pêşkêşkirina rastî (OLM2) li ser vana bêhêra bêtverguhankan
Davê pêşkêşkirina rastî (OLM2) li ser vana bêhêra bêtverguhankan
Ev zarafetê di navbera vebijarkên wekheviyên sererastîdan da ku taybetmendiyên wergerandin:Bijarek SF6: Li ser berzimanek xas bi kar anîn ji bo pîvaneyan destûrê gas SF6. Taybetmendiyên ku hene li benda pîvaneyan derexê gas, bixebitina rûpelên lêzerdanan SF6, û hesabkirina roja bistînin.Analîza Operasyon Mekanîk: Pîvaneyan demên operasyon ên bikeyan û vekeyan. Berhemên pirîmaryên parvekên çendina, kêm kirina, û çendina yekêlîna parvekên. Nîşaneyên lêzerdan mekanîk diteyên, wisa kerdarên zêdetir,
Edwiin
02/13/2025
Funksiyona sivîl bikeşên çalakkirina şevirgiranên dîmender
Funksiyona sivîl bikeşên çalakkirina şevirgiranên dîmender
Funksiyaya da anti-pumping diya nav ne çend ku şîvên kontrolê ji bo naverok e. Ger ê funksiyaya anti-pumping tunebe, duhêt bînin ku karber div rengin dayîn di sîsteman de ya qamrûna. Wanê ger ê serbiseyê bi kurtanên qamrûna li ser dergeha xebitandîneyê hatineke, dema ku serbiseyê bi kurtan di dergeha xebitandîneyê de werek, relâyên parzankirî yên pêşdestkirî werin daxistina tripping bikin. Lakin, div rengin dayîn di sîsteman de ya qamrûna wekheviyeke bike (yenek) ser dergeha xebitandîneyê. Ev pr
Edwiin
02/12/2025
Sernayîna lêgerandina pelên guhertina dîwarî ya nîştmandan de
Sernayîna lêgerandina pelên guhertina dîwarî ya nîştmandan de
ئەمە ئەختەرەوەی سێ بەشی سەرەکی هەیە: ئەسەبە دەستەییەکان: گۆڕانی کارەکان، وەک کارە لۆپەکان، دەتوانێت بەهێزێکی ناوەندی پێبکات. لە کارەکانی زۆرتردا، خاڵێکی تایبەت دەکەوێت بە شوێنێکی تایبەت بەکار بێت، کە بەهێزێکی ناوەندی دەزیادبێت. هەروەها پێکەوەکانی کارەکان دەکەوێت زیاتر بەکار بێت، کە پاشەکەوت سەرەکی کارەکان زیاتر بەهێزێکی ناوەندی دەزیادبێت. ئەسەبە مەکانیکیەکان: چەپڵەکان، زۆربەی جارە لەبەر ڤای، چەمکەرەکەی سەرەکین لەبەر چەپڵەکانن. ئەم چەپڵەکانە دەکەوێت کاتێک دەبێت بەخواردنی کاڵا بکەوێت، کە پاشەکەوت
Edwiin
02/11/2025
Vêgera Heyvî ya Serekekirina Dibîn (ITRV) ji bo karkên kêmûna heyvî
Vêgera Heyvî ya Serekekirina Dibîn (ITRV) ji bo karkên kêmûna heyvî
Dîrokên Bistîna Tirşînê (TRV) wêşî bûyirina ku di dema çewtîna ser xeta berî re tê gotin dê yê ji wan re hebe ku di navbera rastekanê de hatî şert û herî girîng. Dîroka TRV ya bi tenê vê bistîna ya bistînin ya Tirşînê ya Destpêk (ITRV). Ji bo li gorî luma ku di navbera rastekanê de ye, dema ku heta çendînê ya yekemîn ITRV e dibêje ye pêkhatî yên jêrîn yên yek mikrosaniye. Tîra împezdansê ya rastekanê di navendeyek substation de genelî yên wekî yên li ser rêzikên serkeftin ên di navbera rêzikên r
Edwiin
02/08/2025
Pêşnîyar bişînin​
Daxistin
IEE-Business Zêdekirin Bîzînin Wekandin
Bi karanîna sepanê IEE-Business, li her der û her dem amûr bibînin, çareseriyan bistînin, bi pîsporan re têkiliyê ava bikin, û beşdarî hevkariya pîşesaziyê bibin — ev hemû ji pêşveçûna projeyên hêz û karsaziya we re piştgirîyeke tev e.​