How Arc Furnace Transformers and Sympathetic Inrush Currents Affect Grid Voltage and Mitigation Measures?

Leon
Leon
Field: Fault Diagnosis
China

An electric arc furnace is a device that melts metal using the high temperature generated by an electric arc. It converts electrical energy into thermal energy through a transformer, then transfers the heat via the arc to the furnace charge, causing it to melt. When the arc furnace starts operating, the transformer load increases suddenly, leading to a drop in grid voltage. Additionally, due to the operational characteristics of the arc furnace, the load continues to rise over a period of time, which may result in a significant voltage sag. Conversely, when the arc furnace stops, the sudden reduction in transformer load can cause a rise in grid voltage, resulting in a voltage swell.

During arc furnace operation, as the melting and cooling of the charge generate substantial heat, continuous power supply is required. If faults or operational errors occur during power delivery, sympathetic inrush currents (also known as magnetizing inrush currents) may be triggered, further affecting grid stability.

Statistics show that transformer sympathetic inrush currents impact voltage sags in two main ways: first, they cause a sudden increase in grid current, exacerbating the magnitude of voltage sags; second, they may lead to grid voltage instability, increasing the frequency of voltage sags. To prevent voltage sags caused by sympathetic inrush currents in arc furnace transformers, the following three measures are recommended:

  • Optimize arc furnace operation and adjust transformer parameters: Improve operational procedures and fine-tune transformer settings to effectively reduce the magnitude of voltage sags.

  • Adjust arc furnace operating frequency and transformer load ratio: Properly configure the furnace's operating frequency and load ratio to mitigate the severity of voltage sags.

  • Install voltage sag compensation devices: Monitor grid voltage in real time and automatically activate compensation equipment during voltage sags to restore grid voltage to normal levels.

Understanding that arc furnace transformers and sympathetic inrush currents are key contributors to voltage sags enables targeted measures to reduce their impact, thereby enhancing the efficiency and stability of power system operations.

Time is limited, so this concludes today’s discussion. If you would like to learn more about transformer magnetizing inrush currents and mitigation methods, feel free to leave a comment!

Give a tip and encourage the author!
Recommended
3D Wound-Core Transformer: Future of Power Distribution
3D Wound-Core Transformer: Future of Power Distribution
Technical Requirements and Development Trends for Distribution Transformers Low losses, especially low no-load losses; highlighting energy-saving performance. Low noise, particularly during no-load operation, to meet environmental protection standards. Fully sealed designto prevent transformer oil from contacting external air, enabling maintenance-free operation. Integrated protection devices within the tank, achieving miniaturization; reducing transformer size for easier on-site installation. C
Echo
10/20/2025
Reduce Downtime with Digital MV Circuit Breakers
Reduce Downtime with Digital MV Circuit Breakers
Reduce Downtime with Digitized Medium-Voltage Switchgear and Circuit Breakers"Downtime" — it’s a word no facility manager wants to hear, especially when it’s unplanned. Now, thanks to next-generation medium-voltage (MV) circuit breakers and switchgear, you can leverage digital solutions to maximize uptime and system reliability.Modern MV switchgear and circuit breakers are equipped with embedded digital sensors that enable product-level equipment monitoring, providing real-time insights into the
Echo
10/18/2025
One Article to Understand the Contact Separation Stages of a Vacuum Circuit Breaker
One Article to Understand the Contact Separation Stages of a Vacuum Circuit Breaker
Vacuum Circuit Breaker Contact Separation Stages: Arc Initiation, Arc Extinction, and OscillationStage 1: Initial Opening (Arc Initiation Phase, 0–3 mm)Modern theory confirms that the initial contact separation phase (0–3 mm) is critical to the interrupting performance of vacuum circuit breakers. At the beginning of contact separation, the arc current always transitions from a constricted mode to a diffused mode—the faster this transition, the better the interruption performance.Three measures c
Echo
10/16/2025
Advantages & Applications of Low-Voltage Vacuum Circuit Breakers
Advantages & Applications of Low-Voltage Vacuum Circuit Breakers
Low-Voltage Vacuum Circuit Breakers: Advantages, Application, and Technical ChallengesDue to their lower voltage rating, low-voltage vacuum circuit breakers have a smaller contact gap compared to medium-voltage types. Under such small gaps, transverse magnetic field (TMF) technology is superior to axial magnetic field (AMF) for interrupting high short-circuit currents. When interrupting large currents, the vacuum arc tends to concentrate into a constricted arc mode, where localized erosion zones
Echo
10/16/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.