What is High Voltage Testing?


High Voltage Testing Definition


High voltage testing involves procedures to ensure that electrical equipment can withstand various voltage stresses during its operational lifespan.


Transformer Testing Methods


Essential to evaluate the integrity of electrical systems, including tests for dielectric strength, capacitance, and breakdown voltage.


Test Types


There are mainly four types of high voltage testing methods applied on high voltage equipment and these are


Sustained low frequency tests


This test is generally done at power frequency (In China it is 50 Hz and in America it is 60 Hz). This is most commonly used high voltage test, carried on H.V. equipment. This test i.e. sustained low frequency test are carried out on a specimen of insulating material to determine and ensure, dielectric strength, dielectric losses of the insulating material. This test is also carried out on high voltage equipment and high voltage electrical insulators to ensure the dielectric strength and losses of these equipment and insulators.


Sustained Low Frequency Testing Procedure


The testing procedure is very simple. High voltage is applied across a specimen of insulation or equipment under test by means of a high voltage transformer. A resistor is connected with series with the transformer to limit the short circuit current in the event of breakdown occurred in the device under test. The resistor is rated with as many ohms as the high voltage applied across the device under test.


That means the resistance must be rated 1 ohm / volt. For example if we apply 200 KV during the test, the resistor must have 200 KΩ, so that during ultimate short circuit condition, the faulty current must be limited to 1 A. For this test the power frequency high voltage is applied to the specimen or equipment under test for a long specific period to ensure the continuous high voltage withstanding capability of the device.


N. B. : The transformer used for producing extra high voltage in this type of high voltage testing procedure, may not be of high power rating. Although although the output voltage is very high, but maximum current is limited to 1A in this transformer. Sometimes, cascaded transformers are used to get very high voltage, if required.


High Voltage DC Test


High voltage DC test is normally applicable to those equipments which are used in high voltage DC transmission system. But this test is also applicable for high voltage AC equipments, when high voltage AC testing is not possible due to unavoidable condition.


For example mainly at site, after installation of equipments it is quite difficult to arrange for high voltage alternating power as high voltage transformer may not be available at site. Hence, high voltage test with alternating power is not possible at site after installation of equipment. At that situation high voltage DC test is most suitable.


In high voltage direct current test of AC equipment, direct voltage about two times of the normal rated voltage is applied across the equipment under test for 15 minutes to 1.5 hours. Although high voltage DC test is not complete substitute of high voltage AC test but still it is applicable where HVAC test is not at all possible.


High frequency test.


The insulators used at high voltage transmission system, may be subjected to breakdown or flash-over during high frequency disturbances. The high frequency disturbances occur in the HV system due to switching operations or any other external causes. High frequency in power may cause failure of insulators even at comparatively low voltage due to high dielectric loss and heating.


So the insulation of all high voltage equipment must ensure the high frequency voltage withstanding capacity during its normal life span. Mainly sudden interruption of line current during switching and open circuit fault, gives rise to the frequency of voltage wave form in the system.


It is found the dielectric loss for every cycle of the power is nearly constant. So at high frequency the dielectric loss per second becomes much higher than that of normal power frequency. This fast and large dielectric loss causes excessive heating of the insulator. Excessive heating ultimately results to insulation failure may be by blasting of insulators. So to ensure this high frequency voltage withstanding capacity, high frequency test is carried out on high voltage equipments.


Surge or impulse test.


There may be great influence of surge or lighting on the transmission lines. These phenomena can breakdown transmission line insulator and it may also attack, the electrical power transformer connected at the end of the transmission lines. Surge test or impulse tests are very high or extra high voltage tests, carried out for investing the influences of surges or lightning on the transmission equipment.


Normally direct lightening strokes on transmission line is very rare. But when a charged cloud comes closer to the transmission line, the line is oppositely charged due to the electrical charge inside the cloud. When this charged cloud is suddenly discharged due to lightning stroke nearby, the induced charge of the line no longer bound but travel through the line with velocity of light.


So it is understood that even when the lightning do not strike the transmission conductor, directly, still there will be a transient over voltage disturbance.Due to lightning discharge on the line or nearby to the line, a step fronted voltage wave travel along the line. The wave form is shown below.


During traveling of this wave, high voltage stress occurred on the insulator. Due to which violent rupture of insulators is often caused by such lightning impulse. So proper investigation of the insulator and insulating parts of high voltage equipments, should be done properly by high voltage testing.


83283151ae77b235b219beafe1c13cfc.jpeg


Dielectric Strength and Losses


These parameters are crucial in understanding how well insulation can resist electrical stress and heat, particularly under different voltage frequencies.

 


Give a tip and encourage the author!
Recommended
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Transformer Connection Sections
Transformer Connection DesignationsThe transformer connection designation indicates the winding connection method and the phase relationship between the line voltages of the primary and secondary windings. It consists of two parts: letters and a number. The letters on the left denote the connection configurations of the high-voltage and low-voltage windings, while the number on the right is an integer from 0 to 11.This number represents the phase shift of the low-voltage winding's line voltage r
Encyclopedia
08/15/2025
Related Products
  • Top busbar
  • 7.2kV MV motor starter with vacuum contactor up to 7.2 kV
  • Indoor High-Voltage Load Switch
  • ZFW34 Series Gas insulation switchgear (GIS)
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.