What are Dielectric Properties of Insulating Materials?

Encyclopedia
Field: Encyclopedia
0
China


What are Dielectric Properties of Insulating Materials?


Dielectric Definition


A dielectric is defined as a material that does not conduct electricity but can store electrical energy, enhancing the functionality of devices like capacitors

 


81968a3616a1354c2e705a8805d8d8a2.jpeg

 


Breakdown Voltage


The dielectric material has only some electrons in normal operating condition. When the electric strength is increased beyond a particular value, it results in breakdown. That is, the insulating properties are damaged and it finally becomes a conductor. The electrical field strength at the time of breakdown is called breakdown voltage or dielectric strength. It can be expressed in minimum electrical stress that will result in breakdown of the material under some condition.

 


It can be reduced by ageing, high temperature and moisture. It is given as

Dielectric strength or Breakdown voltage 

V→ Breakdown Potential.

t→ Thickness of the dielectric material.


Relative permittivity


It is also called as specific inductive capacity or dielectric constant. This gives us the information about the capacitance of the capacitor when the dielectric is used. It is denoted as εr. The capacitance of the capacitor is related with separation of plates or we can say the thickness of dielectrics, cross sectional area of the plates and the character of dielectric material used . A dielectric material having high dielectric constant is favoured for capacitor.

 


50fcad0398bf08370d3c8d91d49c5d38.jpeg



Relative permeability or dielectric constant = 

fae6d7ed9400839fe2acdd233b07d569.jpeg


缩略图.jpg



We can see that if we substitute air with any dielectric medium, the capacitance (capacitor) will get improved.The dielectric constant and dielectric strength of some dielectric materials are given below.


03f0f3c7504d6d54e9ec8e77d17f34a2.jpeg

Dissipation Factor, Loss Angle and Power Factor


When a dielectric material is given an AC supply, no power utilization takes place. It is perfectly achieved only by vacuum and purified gases. Here, we can see that the charging current will head the voltage applied by 90o which is shown in figure 2A. This implies there is no loss in power in insulators. But most of the cases, there is a dissipation of energy in the insulators when alternating current is applied. This loss is known as dielectric loss. In practical insulators, the leakage current will never lead the voltage applied by 90o (figure 2B). The angle formed by the leakage current is the phase angle (φ). It will be always less than 90. We will also get the loss angle (δ) from this as 90- φ.

 


The equivalent circuit is shown below with capacitance and resistor arranged in parallel.

 


From this, we will get the dielectric power loss as

 


X → Capacitive reactance (1/2πfC)

cosφ → sinδ

In most cases, δ is small. So we can take sinδ = tanδ.

 


So, tanδ is known as power factor of dielectrics.

 


Understanding the properties of dielectric materials is crucial for designing, manufacturing, operating, and recycling these insulators, with assessments typically made through calculations and measurements.

 

2caca7b7ca1b7285fac3979f8ba28a02.jpeg

 d30bec683c1fb9318766e6f59bfc410f.jpeg

Give a tip and encourage the author!
Recommended
Strange Devices on Transmission Lines: 5 Little-Known Practical Functions(1)
1 Aviation Warning SpheresAviation warning spheres, also known as reflective safety spheres, are used on overhead transmission lines near airports, especially on extra-high-voltage (above 220kV) lines and river-crossing transmission lines. Highly visible aviation marker spheres (aviation warning spheres) must be installed along the lines to provide warning signals.The aviation marker sphere (aviation warning sphere) has a diameter of ф=600mm. The sphere can be manufactured in various bright colo
Leon
09/04/2025
Transmission Line
In transmission lines, a "π" connection involves breaking the original line from Substation A to Substation B and inserting Substation C, forming a "π" configuration. After the "π" connection, the original single line is divided into two independent transmission lines. Following the "π" connection, Substations B and C may both be powered by Substation A (in this case, Substation C receives power via a feeder from Substation B's busbar, or possibly from another voltage point within Substation B);
Encyclopedia
09/04/2025
What are the principles of forced re-energization of transmission lines?
Principles of Forced Re-energization of Transmission LinesRegulations for Forced Re-energization of Transmission Lines Correctly select the forced re-energization end of the line. If necessary, change the connection configuration before forced re-energization, taking into account the reduction of short-circuit capacity and its impact on grid stability. There must be a transformer with its neutral point directly grounded on the busbar at the forced re-energization end. Pay attention to the impact
Edwiin
09/04/2025
Analysis of Accident Handling in Transmission Lines
Analysis of Transmission Line Fault HandlingAs a fundamental component of the power grid, transmission lines are widely distributed and numerous, often exposed to diverse geographical and climatic conditions, making them highly susceptible to faults. Common causes include overvoltage, pollution flashover, insulation damage, tree encroachment, and external damage. Line tripping is one of the most frequent faults in power plant and substation operations, with fault types including single-phase-to-
Leon
09/04/2025
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.