H Parameters (Hybrid Parameters) in Two Port Networks

Electrical4u
Field: Basic Electrical
0
China

What are H Parameters (Hybrid Parameters?)

Hybrid parameters (also known as h parameters) are known as ‘hybrid’ parameters as they use Z parameters, Y parameters, voltage ratio, and current ratios to represent the relationship between voltage and current in a two port network. H parameters are useful in describing the input-output characteristics of circuits where it is hard to measure Z or Y parameters (such as in a transistor).

H parameters encapsulate all the important linear characteristics of the circuit, so they are very useful for simulation purposes. The relationship between voltages and current in h parameters can be represented as:

This can be represented in matrix form as:

To illustrate where h parameters are useful, take the case of an ideal transformer, where Z parameters cannot be used. Since here, the relations between voltages and current in that ideal transformer would be,

relation of voltage and current

Since an ideal transformer’s voltage can not be expressed in terms of current, it is impossible to analyze a transformer with Z parameters because a transformer does not have Z parameters. The problem can instead be solved by using hybrid parameters (i.e. h parameters).

How to Find H Parameters in Two Port Networks

Let us short circuit the output port of a two port network as shown below,

two port network

Now, ratio of input voltage to input current, at short circuited output port is:

This is referred to as the short circuit input impedance. Now, the ratio of the output current to input current at the short-circuited output port is:

This is called short-circuit current gain of the network. Now, let us open circuit the port 1. At that condition, there will be no input current (I1=0) but open circuit voltage V1 appears across the port 1, as shown below:

open circuit reverse voltage gain

Now:

This is referred as reverse voltage gain because, this is the ratio of input voltage to the output voltage of the network, but voltage gain is defined as the ratio of output voltage to the input voltage of a network.

Now:

It is referred as open circuit output admittance.

h Parameter Equivalent Network of Two Port Network

To draw h parameter equivalent network of a two port network, first we have to write the equation of voltages and currents using h parameters. These are:

Equation (i) can be represented as a circuit based on Kirchhoff Voltage Law:

kirchhoff Voltage Law

Equation (ii) can be represented as a circuit based on Kirchhoff Current Law:

Kirchhoff current law

Combining these two parts of the network we get:

combing two parts of the network

Inverse Hybrid Parameters or g Parameters

There is another set of parameters which is closely related to the h parameters. These parameters are called inverse hybrid parameters or g parameters. The relations between currents and voltages with g parameters are represented as:

In matrix form:

where:

g Parameter Equivalent Network of Two Port Network

g parameters can be obtained in a similar way to h parameters. The equivalent circuit of two port network using g parameter can be constructed.

The relations between currents and voltages in g parameter are:

As per equation (iii), we can show:

g parameter equivalent network

As per equation (iv) we can show:

g parameter circuit

Combining these two circuits, we get,

The h parameters are used to analyzing Bipolar Junction Transistor or BJT. Whereas, g parameter are used to analyzing Junction Field Effect Transistor or JFET.

Source: Electrical4u.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.


Give a tip and encourage the author!
Recommended
What are the methods for handling single-phase grounding faults in the small-current grounding system of the distribution network?
Current Status of Single-Phase Grounding Fault DetectionThe low accuracy of single-phase grounding fault diagnosis in non-effectively grounded systems is attributed to several factors: the variable structure of distribution networks (such as looped and open-loop configurations), diverse system grounding modes (including ungrounded, arc-suppression coil grounded, and low-resistance grounded systems), the increasing annual ratio of cable-based or hybrid overhead-cable wiring, and complex fault typ
Leon
08/01/2025
Frequency division method for measuring grid-to-ground insulation parameters
The frequency division method enables the measurement of grid-to-ground parameters by injecting a current signal of a different frequency into the open delta side of the potential transformer (PT).This method is applicable to ungrounded systems; however, when measuring the grid-to-ground parameters of a system where the neutral point is grounded via an arc suppression coil, the arc suppression coil must be disconnected from operation beforehand. Its measurement principle is shown in Figure 1.As
Leon
07/25/2025
The insulation parameters of the power grid to ground are measured by the tuning method
The tuning method is suitable for measuring the ground parameters of systems where the neutral point is grounded via an arc suppression coil, but not applicable to ungrounded neutral point systems. Its measurement principle involves injecting a current signal with continuously varying frequency from the secondary side of the Potential Transformer (PT), measuring the returned voltage signal, and identifying the system's resonant frequency.During the frequency sweeping process, each injected heter
Leon
07/25/2025
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
In an arc - suppression coil grounding system, the rising speed of the zero - sequence voltage is greatly affected by the value of the transition resistance at the grounding point. The larger the transition resistance at the grounding point, the slower the rising speed of the zero - sequence voltage.In an ungrounded system, the transition resistance at the grounding point has basically no impact on the rising speed of the zero - sequence voltage.Simulation Analysis: Arc - suppression Coil Ground
Leon
07/24/2025
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.