What are the causes of failures in low-voltage switchgear circuit breakers themselves?
What are the causes of failures in low-voltage switchgear circuit breakers themselves?
Based on years of field statistics on switchgear accidents, combined with analysis focusing on the circuit breaker itself, the main causes have been identified as: failure of operation mechanism; insulation faults; poor breaking and closing performance; and poor conductivity.1.Failure of Operation MechanismFailure of operation mechanism manifests as delayed operation or unintended operation. Since the most basic and important function of a high-voltage circuit breaker is to operate correctly and
Felix Spark
11/04/2025
කොටස් ධාරාවලට පැත්තේ විද්‍යුත් කිරණ පෙළගැනීමට පිළිබඳ සාධක කුමක්ද?
කොටස් ධාරාවලට පැත්තේ විද්‍යුත් කිරණ පෙළගැනීමට පිළිබඳ සාධක කුමක්ද?
1. ප්‍රේරණය එක්සත් කරන විද්‍යුත් අධික තීගැටුමප්‍රේරණය එක්සත් කරන විද්‍යුත් අධික තීගැටුම යනු මීට අඩු දුරක සිටින විද්‍යුත් ඝාතන උත්පාදන රේඛාවල ඇති පැහැදෙන අධික තීගැටුමකි, එය රේඛාව ප්‍රතික්ත්‍රමාසිත් ඝාතන උත්පාදන නොකළ විටද ප්‍රතිඵලයක් වන අතර ඝාතන උත්පාදන මෙහෙයුම් විට ප්‍රේරණය එක්සත් කරන ලද අධික බාධා මෙය මූලික අවස්ථාවකි.සංඛ්‍යාත්මක දත්ත පෙන්නුම් කරන්නේ ප්‍රේරණය එක්සත් කරන අධික තීගැටුම් නිසා ඇති වන ඝාතන උත්පාදන විශේෂ චින්තනය ප්‍රමාණයට ආසන්න රේඛාවල උත්පාදන උත්පාදන උත්පාදන ප්‍රමාණයේ 90% ලෙස පෙන්නුම් කර
Echo
11/03/2025
Compact Air-Insulated RMUs for Retrofit & New Substations
Compact Air-Insulated RMUs for Retrofit & New Substations
Air-insulated ring main units (RMUs) are defined in contrast to compact gas-insulated RMUs. Early air-insulated RMUs used vacuum or puffer-type load switches from VEI, as well as gas-generating load switches. Later, with the widespread adoption of the SM6 series, it became the mainstream solution for air-insulated RMUs. Similar to other air-insulated RMUs, the key difference lies in replacing the load switch with an SF6-encapsulated type—where the three-position switch for load and grounding is
Echo
11/03/2025
SF6 Leak Detection Methods for GIS Equipment
SF6 Leak Detection Methods for GIS Equipment
For SF6 gas leakage rate detection in GIS equipment, when using the quantitative leak detection method, the initial SF6 gas content in the GIS equipment must be accurately measured. According to relevant standards, the measurement error should be controlled within ±0.5%. The leakage rate is calculated based on changes in gas content after a period of time, thereby evaluating the sealing performance of the equipment.In qualitative leak detection methods, direct visual inspection is commonly used,
Oliver Watts
10/31/2025