Batteries in Series and Batteries in Parallel

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

Battery Cells

Battery is an electrical element where electrical potential is produced due to chemical reaction. Every electrochemical reaction has its limit of producing electric potential difference between two electrodes.
Battery cells are those where these electro-chemical reactions take place to produce the limited electric potential difference. For achieving desired electric potential difference across the battery terminals multiple numbers of cells are to be connected in series. Hence it can be concluded like that, a battery is a combination of several cells where a cell is a unit of a battery. For example, Nickel-cadmium battery cells normally develop about 1.2 V per cell while
lead acid battery develop about 2 V per cell. So a 12 volt battery will have total 6 number of cells connected in series.

EMF of Battery

If anyone just measures the electric potential difference between two terminals of a battery when load is not connected with the battery, he or she will get the voltage developed in the battery when there is no current flowing through it. This voltage is generally referred as electromotive force or emf of battery. It is also referred as no-load voltage of battery.

Terminal Voltage of Battery

Terminal voltage of battery is the potential difference across its terminals when the current is being drawn from it. Actually when load is connected with the battery, there will be load current flowing through it. As a battery is an electrical equipment, it must have some electrical resistance inside it. Because of this internal resistance of battery , there will be some voltage drops across it. So, if any one measures the terminal voltage of the load i.e. terminal voltage of battery when load is connected, he or she will get the voltage which is less than emf of the battery by internal voltage drop of the battery.

If E is the emf or no-load voltage of the battery and V is the terminal voltage of load voltage of the battery, then E – V = internal voltage drop of the battery.
As per
Ohm’s law, this internal voltage drop is nothing but the product of electrical resistance offered by the battery and the current flows through it.

Internal Resistance of Battery

The entire resistance encountered by a current as if it flows through a battery from the negative terminal to the positive terminal is known as internal resistance of battery.

Series Parallel Batteries

Battery cells can be connected in series, in parallel and as well as a mixture of both the series and parallel.

Series Batteries

When in a battery, positive terminal of one cell is connected with the negative terminal of succeeding cell, then the cells are said to be series connected or simply series battery. Here, overall emf of the battery is algebraic sum of all individual cells connected in series. But overall discharged current of the battery does not exceed the discharged current of individual cells.

series batteries

If E is the overall emf of the battery combined by n number cells and E1, E2, E3, …………… En are the emfs of individual cells.


Similarly, if r1, r2, r3, …………… rn are the internal resistances of individual cells, then the internal resistance of the battery will be equal to the sum of the internal resistance of the individual cells i.e.


parallel batteries

Parallel Batteries

When positive terminals of all cells are connected together and similarly negative terminals of these cells are connected together in a battery, then the cells are said to be connected in parallel. These combinations are also referred as parallel batteries. If emf of each cell is identical, then the emf of the battery combined by n numbers of cells connected in parallel, is equal to the emf of each cell. The resultant internal resistance of the combination is,


The current delivered by the battery is sum of currents delivered by individual cells.

Mixed Grouping of Batteries or Series Parallel Batteries

As we said earlier, the cells in a battery can also be connected in mixture of both series and parallel. These combinations are some time referred as series parallel battery . A load can require both voltage and current more than that of an individual battery cell. For achieving the required load voltage, the desired numbers of battery cells can be combined in series and for achieving the required load current, desired numbers of these series combinations are connected in parallel. Let m, numbers of series, each containing n numbers of identical cells, are connected in parallel.

series parallel batteries

Again assume emf of each cell is E and internal resistance of each cell is r. As n numbers of cells are connected in each series, the emf of each series as well as the battery will be nE. The equivalent resistance of the series is nr. As, m number of series connected in parallel equivalent internal resistance of that series and parallel battery is nr/m.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic (PV) Power Generation SystemsA photovoltaic (PV) power generation system is primarily composed of PV modules, a controller, an inverter, batteries, and other accessories (batteries are not required for grid-connected systems). Based on whether it relies on the public power grid, PV systems are divided into off-grid and grid-connected types. Off-grid systems operate independently without relying on the utility grid. They are equipped with energy-s
Encyclopedia
10/09/2025
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(2)
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(2)
1. On a scorching sunny day, do damaged vulnerable components need to be replaced immediately?Immediate replacement is not recommended. If replacement is necessary, it is advisable to do so in the early morning or late afternoon. You should contact the power station’s operation and maintenance (O&M) personnel promptly, and have professional staff go to the site for replacement.2. To prevent photovoltaic (PV) modules from being hit by heavy objects, can wire mesh protective screens be install
Encyclopedia
09/06/2025
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(1)
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(1)
1. What are the common faults of distributed photovoltaic (PV) power generation systems? What typical problems may occur in various components of the system?Common faults include inverters failing to operate or start due to voltage not reaching the startup set value, and low power generation caused by issues with PV modules or inverters. Typical problems that may occur in system components are burnout of junction boxes and local burnout of PV modules.2. How to handle common faults of distributed
Leon
09/06/2025
How to Design and Install a Standalone Solar PV System?
How to Design and Install a Standalone Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utiliti
Edwiin
07/17/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.