What is the purpose of connecting the primary winding of a step-up transformer in series with the main supply and the secondary winding in parallel?

10/07/2024

The situation where the primary winding of a booster transformer is connected in series with the main power supply and the secondary winding is connected in parallel with the main power supply is not common in practical applications, because this connection method usually does not bring the expected benefits and may introduce unnecessary complexity and potential risks. However, assuming that this configuration is for a specific function, we can explore its possible purpose and application scenarios.


Series primary winding for purpose


When the primary winding of the booster transformer is connected to the main power supply in series, it means that the input end of the transformer is directly connected to the power line. This connection is usually intended to use the transformer as an impedance matching element or as a voltage regulator.


Purpose of parallel secondary winding


When the secondary winding of the booster transformer is in parallel with the main supply, it means that the voltage output by the secondary winding will be in parallel with the main supply voltage. This type of connection is usually used to provide a higher voltage output, and in some cases can be used to compensate for a lack of grid voltage.


Possible purpose


  • Voltage boost: If the grid voltage is lower than the required operating voltage, the voltage can be raised to the required level through a boost transformer. The secondary winding is in parallel with the main power supply to ensure that even in the case of grid voltage fluctuations, the load can get a stable high voltage.


  • Impedance matching: In some applications, it is necessary to match the impedance of the power supply to the impedance of the load to maximize power transfer efficiency. By connecting the primary windings in series, the impedance of the entire circuit can be adjusted.


  • Voltage regulation: The booster transformer can act as a voltage regulator to ensure that the voltage at both ends of the load is maintained at a constant level.


  • In the case of parallel connection, the booster transformer can supplement the shortage of grid voltage and ensure the voltage stability at both ends of the load.


  • Current limitation: In some cases, it may be necessary to limit the current through the load. By connecting the primary winding in series, it can play the role of current limiting. The parallel connection of the secondary windings ensures that the voltage at both ends of the load is not too affected by the current limitation.



Precautions in practical application


Although the above configuration may have some use in theory, there are several points to note in practical applications:


  • Safety: Placing the secondary winding in parallel with the main power supply can introduce safety hazards, especially if not properly designed, which can lead to short circuits or other dangerous conditions.


  • Efficiency: This configuration may not be the most efficient solution, as the loss and efficiency issues of the transformer need to be carefully considered.


  • Stability: A parallel connection may affect the stability of the system, especially if the grid voltage fluctuates.



More common ways to connect


In practical applications, it is more common to connect the primary winding of the booster transformer to the main power supply, while the secondary winding is directly connected to the load. This connection method can effectively increase the voltage, and is relatively simple and safe.


Sum up


The configuration of the primary winding of the booster transformer in series with the main power supply and the secondary winding in parallel with the main power supply can realize the functions of voltage boost, impedance matching, voltage regulation and current limitation in theory, but its safety and efficiency need to be carefully considered in practical applications. It is more common to connect the primary winding of the booster transformer directly to the main power supply and the secondary winding to the load. If you are considering this configuration in a specific application scenario, make sure that the design meets safety standards and has been thoroughly analyzed and tested.


Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.

Difference Between Short Circuit & Overload
Difference Between Short Circuit & Overload
One of the main differences between a short circuit and an overload is that a short circuit occurs due to a fault between conductors (line-to-line) or between a conductor and earth (line-to-ground), whereas an overload refers to a situation where equipment draws more current than its rated capacity from the power supply.Other key differences between the two are explained in the comparison chart below.The term "overload" typically refers to a condition in a circuit or connected device. A circuit
08/28/2025
Difference Between Leading and Lagging Power Factor
Difference Between Leading and Lagging Power Factor
Leading and lagging power factors are two key concepts related to the power factor in AC electrical systems. The main difference lies in the phase relationship between current and voltage: in a leading power factor, the current leads the voltage, whereas in a lagging power factor, the current lags behind the voltage. This behavior depends on the nature of the load in the circuit.What is Power Factor?Power factor is a crucial, dimensionless parameter in AC electrical systems, applicable to both s
08/26/2025
Difference Between Electromagnet and Permanent Magnet
Difference Between Electromagnet and Permanent Magnet
Electromagnets vs. Permanent Magnets: Understanding the Key DifferencesElectromagnets and permanent magnets are the two primary types of materials that exhibit magnetic properties. While both generate magnetic fields, they differ fundamentally in how these fields are produced.An electromagnet generates a magnetic field only when an electric current flows through it. In contrast, a permanent magnet inherently produces its own persistent magnetic field once it has been magnetized, without requirin
08/26/2025
Interpretation of the “Five Mandatory Surveys” for On - site Investigation in the Operation and Maintenance Specialty
Interpretation of the “Five Mandatory Surveys” for On - site Investigation in the Operation and Maintenance Specialty
The power outage and work scopes must be clearly inspectedCollaborate with the site survey leader to confirm the equipment to be maintained and the work area involved. Consider requirements such as the use of special vehicles and large machinery, and safe distances from adjacent energized equipment. Verify on-site whether the proposed power outage scope is sufficient to meet the operational needs.On-site safety measures must be clearly inspectedCollaborate with the site survey leader to verify s
Vziman
08/14/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!