What happens to a coil when AC current is passed through it? How does it avoid getting burnt?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

When an alternating current passes through a coil, the following situations occur:

I. Electromagnetic effects

1. Generation of a magnetic field

 When an alternating current passes through a coil, an alternating magnetic field is generated around the coil. The intensity of this magnetic field changes with the change of current.

For example, in an electromagnet, when an alternating current passes through a coil, a magnetic field that attracts ferromagnetic objects is generated. The direction and intensity of this magnetic field change with the change of direction and magnitude of the alternating current.

2. Induced electromotive force

According to Faraday's law of electromagnetic induction, a changing magnetic field will generate an induced electromotive force in the coil. The direction of this induced electromotive force is opposite to the direction of change of current and is called self-induced electromotive force.

For example, when the alternating current increases, the self-induced electromotive force will hinder the increase of current; when the alternating current decreases, the self-induced electromotive force will hinder the decrease of current. This self-induction phenomenon plays an important role in alternating current circuits. For example, inductive elements can be used for filtering and current limiting.

II. Energy loss

1. Resistance loss

The coil itself has a certain resistance. When an alternating current passes through the coil, power loss will occur on the resistance, manifested as heating.

For example, if the resistance of a coil is R and the alternating current passing through it is I, then the power loss of the coil is P=I2R . If the current is large or the coil resistance is large, the power loss will increase, leading to an increase in the coil temperature.

2. Eddy current loss

Under the action of an alternating magnetic field, eddy currents will be generated inside the conductor of the coil. Eddy currents will generate power loss in the conductor, also manifested as heating.

For example, in the iron core of a transformer, due to the action of an alternating magnetic field, eddy current loss will occur. To reduce eddy current loss, the iron core of a transformer usually adopts a laminated structure to increase the path resistance of eddy currents and reduce the magnitude of eddy currents.

III. Methods to avoid burnout

1. Select appropriate coil parameters

According to the needs of practical applications, select appropriate coil parameters such as the number of turns, wire diameter, and insulation material. Increasing the number of turns of the coil can increase the inductance value, but it will also increase the resistance and volume; choosing a larger wire diameter can reduce the resistance, but it will also increase the cost and volume.

For example, when designing an inductive filter, appropriate coil parameters need to be selected according to parameters such as input and output voltage, current, and frequency to meet the filtering requirements and avoid overheating and burnout of the coil.

2. Strengthen heat dissipation measures

To reduce the temperature of the coil, heat dissipation measures can be strengthened, such as adding heat sinks, ventilation holes, fans, etc. Heat sinks can increase the contact area between the coil and air and improve heat dissipation efficiency; ventilation holes can promote air circulation and take away the heat generated by the coil; fans can force air flow and accelerate the heat dissipation speed.

For example, in an electronic device with high power, the coil is usually installed on a heat sink and is cooled by ventilation holes or fans. This can effectively reduce the temperature of the coil and avoid burnout.

3. Control current and voltage

Avoid passing excessive current or subjecting the coil to excessive voltage. Appropriate protective elements such as fuses, circuit breakers, and voltage regulators can be used to limit the magnitude of current and voltage.

For example, in a power supply circuit, to prevent the coil from burning out due to overcurrent, a fuse can be installed in the circuit. When the current exceeds the rated current of the fuse, the fuse will blow and cut off the circuit to protect the coil and other elements.

4. Regular inspection and maintenance

Regularly inspect the appearance, temperature, insulation performance, etc. of the coil, and find and deal with potential problems in time. If overheating, discoloration, abnormal smell, etc. are found on the coil, stop using it immediately and conduct inspection and repair.

For example, in an electronic device that operates for a long time, the coil should be inspected and maintained regularly, dust and debris should be cleaned up, the insulation should be checked for good condition, and the resistance and inductance values of the coil should be measured. This can detect problems with the coil in time and take corresponding measures to avoid burnout.

In summary, when an alternating current passes through a coil, the coil will generate a magnetic field, induced electromotive force, and energy loss. To avoid burnout of the coil, appropriate coil parameters can be selected, heat dissipation measures can be strengthened, current and voltage can be controlled, and regular inspection and maintenance can be carried out.


Give a tip and encourage the author!
Recommended
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic (PV) Power Generation SystemsA photovoltaic (PV) power generation system is primarily composed of PV modules, a controller, an inverter, batteries, and other accessories (batteries are not required for grid-connected systems). Based on whether it relies on the public power grid, PV systems are divided into off-grid and grid-connected types. Off-grid systems operate independently without relying on the utility grid. They are equipped with energy-s
Encyclopedia
10/09/2025
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(2)
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(2)
1. On a scorching sunny day, do damaged vulnerable components need to be replaced immediately?Immediate replacement is not recommended. If replacement is necessary, it is advisable to do so in the early morning or late afternoon. You should contact the power station’s operation and maintenance (O&M) personnel promptly, and have professional staff go to the site for replacement.2. To prevent photovoltaic (PV) modules from being hit by heavy objects, can wire mesh protective screens be install
Encyclopedia
09/06/2025
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(1)
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(1)
1. What are the common faults of distributed photovoltaic (PV) power generation systems? What typical problems may occur in various components of the system?Common faults include inverters failing to operate or start due to voltage not reaching the startup set value, and low power generation caused by issues with PV modules or inverters. Typical problems that may occur in system components are burnout of junction boxes and local burnout of PV modules.2. How to handle common faults of distributed
Leon
09/06/2025
Short Circuit vs. Overload: Understanding the Differences and How to Protect Your Power System
Short Circuit vs. Overload: Understanding the Differences and How to Protect Your Power System
One of the main differences between a short circuit and an overload is that a short circuit occurs due to a fault between conductors (line-to-line) or between a conductor and earth (line-to-ground), whereas an overload refers to a situation where equipment draws more current than its rated capacity from the power supply.Other key differences between the two are explained in the comparison chart below.The term "overload" typically refers to a condition in a circuit or connected device. A circuit
Edwiin
08/28/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.