Search


Pemutus Sirkuit Gas SF6 Tangki Mati RHD

  • Customization 24 kV/25.8 kV/27 kV/145kV/138kV/230kV or Other Dead tank SF6 Gas Circuit-Breaker
  • Customization 24 kV/25.8 kV/27 kV/145kV/138kV/230kV or Other Dead tank SF6 Gas Circuit-Breaker

Atribut Kunci

Merek ROCKWILL
Seri RHD
Deskripsi

Product Overview

The RHD Series Dead-Tank SF6 Circuit Breaker is engineered for 'customized high-voltage power system solutions', covering standard voltage grades from RHD-40.5 to RHD-550 and supporting 'non-standard voltage customization' to precisely match your unique grid upgrade or construction needs. As a dead-tank type, its grounded tank isolates high-voltage components, ensuring superior insulation performance and safety--making it the go-to choose for demanding high-voltage scenarios.

About customization

We offer full customization services for voltage classes, including single-phase, two-phase, and three-phase configurations, as well as non-standard voltage/current solutions. Examples of available voltage and current specifications include 1250 A 75 kV, 3200 A 46 kV, 60 kV, 69 kV, and 75 kV (we support customization ranging from 10 kV to 800 kV for voltage and 1250 A to 6300 A for current). Regardless of your power grid's voltage specifications, we tailor the circuit breaker for seamless integration.

All products are fully assembled and tested at our factory before being shipped directly to your site--no disassembly of key components is required. This eliminates the need for on-site high-voltage testing, significantly saving you time and costs.

Key features

 1. Superior Seismic Resistance

Adopting a low-center-of-gravity design, the breaker can withstand an earthquake intensity of up to 9 degrees, ensuring stable performance in seismic-prone areas--consistent with the RHD series' proven anti-seismic capability.

2. Excellent Arc-Extinguishing Performance & Long Service Life

Leveraging the high arc-extinguishing efficiency of SF6 gas, the breaker achieves a rated short-circuit breaking current of ≥50kA. It boasts an electrical life of more than 20 operations and a mechanical life of up to 10,000 cycles, significantly reducing equipment replacement and maintenance costs.

3. Low SF6 Gas Leakage Rate

The hermetic metal tank structure minimizes SF6 gas leakage, with an annual leakage rate of ≤1%--far below industry averages. This design not only avoids safety hazards from gas leakage but also reduces environmental impact. 

4. Modular Design & Flexible Expansion

It supports on-demand configuration of built-in current transformers (CTs), with up to 15 CTs available for measurement or protection purposes. The standardized module interface allows flexible combination to meet diverse substation design and layout requirements, especially suitable for space-constrained scenarios.

5. Strong Environmental Adaptability

The breaker operates stably in extreme conditions: ambient temperature ranging from -40℃ to +55℃, maximum daily temperature difference of 32K, altitude up to 3,000m, and air pollution level up to Class IV. It also resists wind pressure of 700Pa (equivalent to 34m/s wind speed) and icing thickness of up to 20mm.

6. Comprehensive Safety Protection

Equipped with anti-mis operation interlocking devices, it effectively prevents accidents caused by incorrect operations. Before delivery, the breaker undergoes lightning impulse tests to eliminate insulation discharge risks from production and assembly, ensuring reliable quality.

7. Maintenance-Free Operating Mechanism

It adopts a spring-operated mechanism that is oil-free, gas-free, and maintenance-free. This mechanism delivers stable performance, low noise, and high reliability, reducing long-term operational workload.

Technology Parameters

Item Unit Parameters
customization of Rated Voltage kV

3.6 kV/4.76 kV/7.2 kV/8.25 kV/12 kV /13.2 kV/11kV/12kV/13.8kV/15kV/15.5 kV /17.5 kV/22kV/22.9 kV/24 kV/25.8 kV/27 kV/33kV/36 kV/38 kV/40.5 kV/44kV/60kV/63kV/66kV/69kV/88kV/115kV/123kV/125kV/126kV/132kV/138kV/145kV/

150kV/170kV/184kV/204kV/220kV/225kV/230kV/245kV/275kV/330kV/345kV/400kV/765kV/800kV

customization of Rated  current A 1250 to 6300
Rated frequency Hz 50/60
1min Power frequency withstand voltage kV Max to 750
Lightning impulse withstand voltage kV Max to 1675
First open pole factor   1.5/1.3/1.55
Rated short circuit breaking current kA 16 to 63
Rated short - circuit duration s 4,3
Rated out - of - phase breaking current   10
Rated cable charging current   10/50/125
Rated peak value withstand current kA 80/100/125
Rated making current (peak) kA 80/100/125
Creepage distance mm/kV 25 - 31
SF6 gas leakage rate (per year)   ≤1%
Rated SF6 gas pressure(20℃ gauge pressure) Mpa 0.5/0.4,0.5,0.6
Alarm/blocking pressure(20℃ gauge pressure) Mpa 0.45/0.4,0.35/0.33,0.45/0.40,0.55/0.50
SF6 annual gas leakage rate   ≤0.5
Gas moisture content Ppm(v) ≤150
Heater voltage   AC220/DC220
Voltage of control circuit DC DC110/DC220/DC230
Voltage of energy - store motor V DC 220/DC 110/AC 220/DC230
Applied standards   GB/T 1984/IEC 62271 - 100

 

Name unit Parameters
Opening time ms 27±3
Closing time ms 90±9
Minute and conjunction time ms 300
Together--ivide the time ms ≤60
Simultaneity of opening ms ≤3
Closing simultaneity ms ≤5
Moving contact stroke mm 150+2-4
Contact contact stroke mm 27±4
Opening speed m/s 4.5±0.5
Closing speed m/s 2.5±0.4
Mechanical life times 6000
Operation sequence   O - 0.3s - CO - 180s - CO
Note: The opening and closing speed and time are the characteristic values of the circuitbreaker when it is single divided and closed under rated conditions. The closing speed is theaverage speed of the moving contact from the rigid closing point to 10 ms before closing, andthe opening speed is the average speed of the moving contact within 10 ms from the justequinox to 10 ms after the separation.

Application Scenarios

  1. Large Hub Substations

Ideal for 220kV+ key hub substations, the customized RHD breaker controls and protects main power circuits. Its non-standard voltage adaptability ensures seamless integration into existing or upgraded grid architecture.

  1. New Energy Grid-Connection Systems

Suitable for high-voltage grid connections in wind and solar power bases. Custom voltage ratings ensure reliable integration of renewable energy into the main grid, even in projects with unique voltage requirements.

  1. Industrial High-Voltage Power Systems

Perfect for heavy industries (metallurgy, chemicals) with specialized voltage needs. The breaker’s robust performance and customizability guarantee stable power supply for high-power industrial equipment.

 

 

 

Perpustakaan Sumber Dokumen Dead Tank Circuit Breaker

Restricted
RHD-Dead Tank SF6 Circuit Breaker Catalog RHD-Dead Tank SF6 Circuit Breaker Catalog
Catalogue
English
PDF
Restricted
138kV Dead-Tank Circuit Breaker Technical Specification | IEC Compliant 138kV Dead-Tank Circuit Breaker Technical Specification | IEC Compliant
Technical Data
Chinese
PDF
Restricted
138kV Dead‑Tank Circuit Breaker Technical Specification | IEEE & ANSI Compliant 138kV Dead‑Tank Circuit Breaker Technical Specification | IEEE & ANSI Compliant
Technical Data
English
PDF
Restricted
2026 RHD Dead tank SF6 gas circuit breaker 2026 RHD Dead tank SF6 gas circuit breaker
Catalogue
English
PDF
Public.
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English
Public.
RHD-362 SF6 Gas Dead tank Circuit Breaker FLYER RHD-362 SF6 Gas Dead tank Circuit Breaker FLYER
Brochure
English
Public.
RHD-420 SF6 Gas Dead tank Circuit Breaker FLYER RHD-420 SF6 Gas Dead tank Circuit Breaker FLYER
Brochure
English
Public.
RHD-362 SF6 Gas Dead tank Circuit Breaker RHD-362 SF6 Gas Dead tank Circuit Breaker
Drawings
English

Pertanyaan yang Sering Diajukan

Struktur Tank Integral:

  • Struktur Tank Integral: Ruang pemadam busur, medium isolasi, dan komponen terkait lainnya dari pemutus disegel dalam tangki logam yang diisi dengan gas isolasi (seperti sulfur heksafluorida) atau minyak isolasi. Ini membentuk ruang yang relatif mandiri dan tertutup, secara efektif mencegah faktor lingkungan eksternal mempengaruhi komponen internal. Desain ini meningkatkan kinerja isolasi dan keandalan peralatan, menjadikannya cocok untuk berbagai lingkungan luar yang keras.

Tata Letak Ruang Pemadam Busur:

  • Tata Letak Ruang Pemadam Busur: Ruang pemadam busur biasanya dipasang di dalam tangki. Strukturnya dirancang agar padat, memungkinkan pemadam busur yang efisien dalam ruang terbatas. Bergantung pada prinsip dan teknologi pemadam busur yang berbeda, konstruksi spesifik ruang pemadam busur mungkin bervariasi, tetapi umumnya mencakup komponen kunci seperti kontak, nozzle, dan bahan isolasi. Komponen-komponen ini bekerja sama untuk memastikan bahwa busur dapat dipadamkan dengan cepat dan efektif saat pemutus menghentikan arus.

Mekanisme Pengoperasian:

  • Mekanisme Pengoperasian: Mekanisme pengoperasian yang umum termasuk mekanisme pegas dan mekanisme hidrolik.

  • Mekanisme Pegas: Jenis mekanisme ini sederhana strukturnya, sangat andal, dan mudah dirawat. Ia menggerakkan operasi buka-tutup pemutus melalui penyimpanan dan pelepasan energi pegas.

  • Mekanisme Hidrolik: Mekanisme ini menawarkan keuntungan seperti daya output tinggi dan operasi yang halus, menjadikannya cocok untuk pemutus kelas tegangan dan arus tinggi.

1. Pilih pemutus sirkuit yang sesuai dengan tingkat tegangan berdasarkan tingkat jaringan listrik
Tegangan standar (40,5/72,5/126/170/245/363/420/550/800/1100kV) disesuaikan dengan tegangan nominal jaringan listrik yang sesuai. Misalnya, untuk jaringan listrik 35kV, dipilih pemutus sirkuit 40,5kV. Berdasarkan standar seperti GB/T 1984/IEC 62271-100, tegangan nominal dijamin ≥ tegangan operasional maksimum jaringan listrik.
2. Skenario yang cocok untuk tegangan khusus non-standar
Tegangan khusus non-standar (52/123/230/240/300/320/360/380kV) digunakan untuk jaringan listrik khusus, seperti renovasi jaringan listrik lama dan skenario industri listrik tertentu. Karena kurangnya tegangan standar yang sesuai, produsen perlu menyesuaikan berdasarkan parameter jaringan listrik, dan setelah penyesuaian, kinerja isolasi dan pemadam busur harus diverifikasi.
3. Konsekuensi memilih tingkat tegangan yang salah
Memilih tingkat tegangan yang rendah dapat menyebabkan kegagalan isolasi, yang mengakibatkan kebocoran SF dan kerusakan peralatan; Memilih tingkat tegangan yang tinggi secara signifikan meningkatkan biaya, meningkatkan kesulitan operasional, dan mungkin juga menyebabkan masalah ketidaksesuaian kinerja.

Kenali Pemasok Anda

Toko online
Tingkat pengiriman tepat waktu
Waktu Tanggapan
100.0%
≤4h
Tinjauan Perusahaan
Tempat Kerja: 108000m² Total karyawan: 700+ Ekspor Tertinggi Tahunan USD: 150000000
Layanan
Jenis Bisnis: Desain/Manufacture/Penjualan
Kategori Utama: transformator/Gardu Induk Paket dan Ruang Elektrikal Prefabrikasi/Insulasi Penangkal Petir dan Proteksi Petir/Perangkat Listrik Tekanan Tinggi/Panel Listrik dan Perangkat Kontrol/transformator
Pertanyaan
+86
Klik untuk mengunggah file
Unduh
Dapatkan Aplikasi Bisnis IEE-Business
Gunakan aplikasi IEE-Business untuk menemukan peralatan mendapatkan solusi terhubung dengan ahli dan berpartisipasi dalam kolaborasi industri kapan saja di mana saja mendukung sepenuhnya pengembangan proyek dan bisnis listrik Anda
Masuk
atau lanjutkan dengan
Baru di sini?
Daftar