V
Sharararwa

Na iyi ɗaya aiki na transformer turns ratio da wannan aiki na tushen online. Yana a yi amfani da uku daga cikin abubuwa — primary voltage, secondary voltage, primary turns ko kuma secondary turns — don samun parametarin da ba a bayyana shi ba a baya. An gina shi don mafi girman electrical engineers da power system designers, yana da kyau, mai inganci, kuma yana iya amfani a kan ƙarfin adadin — babu need for sign-up.

Primary Voltage (Vp): AC input voltage applied to the high-voltage winding (in volts).
Secondary Voltage (Vs): AC output voltage from the low-voltage winding (in volts).
Primary Turns (Np): Number of conductor loops in the primary coil.
Secondary Turns (Ns): Number of conductor loops in the secondary coil.
Duk calculations assume an ideal transformer model—core losses, leakage flux, and resistance are neglected for theoretical accuracy in design-phase estimation.

The calculator uses the fundamental transformer equation:

Vp/Vs = Np/Ns

This ratio is critical in power distribution, isolation transformer design, and voltage adaptation for industrial equipment. For example: designing a step-down transformer from 480 V to 120 V with 800 primary turns yields exactly 200 secondary turns—enabling rapid prototyping and specification validation in real-world projects.


Ba da kyau kuma kara mai rubutu!
Tambayar Da Yawanci
Maximum short-circuit current with transformer substation
Kurumanci kasa daɗi a cikin IEE-Business
Wani alat na iya kula da adadin karamin karamin karamin da ake zama a cikin tashar gida daga wurin maimaita, ta hanyar IEC 60865 da IEEE C37.100. Abubuwan da aka bayyana sun fi yawa don zan iya zaɓe wasu abubuwa masu sauki, kamar fadada, wakanda, kable, da kuma nasara, kuma don duba yadda ake iya suka daidai kan karamin karamin. Abubuwan Da Ake Bincike Karamin Karamin Masu Noma (MVA): Karamin karamin da ke faru a wurin maimaita, wanda ya nuna kyauwar mutummai. Adadin karshe suna zama da karamin karamin da ke faru. Voltaji Mai Tsarki (kV): Voltajin da ake tsari a wurin maimaitar (misali, 10 kV, 20 kV, 35 kV). Voltaji Mai Yawa (V): Voltajin da ake tsari a wurin maimaitar mai yawa (tushen 400 V ko 220 V). Kwara Wuri (kVA): Kwara mai tsari na maimaitar. Voltaji Mai Faru (%): Yawan tsaro mai faru (U k %), wanda ake bayar da shi mai karatu. Wani muhimmiyar abu a kan kula da adadin karamin karamin da ke faru. Mafi Yawan Zabi (%): Yawan zabi a matsayin faidan da ya kawo (P c %), wanda ake amfani da shi don kula da takam addinin. Tsawon Kable Mai Tsarki: Tsawon kable mai tsarki daga maimaitar zuwa abokin (a m, ft, ko yd), wanda ya haɗa da tsaron kable. Nau'in Kable: Zaka nau'in kable: Kable mai yanki Kable mai sifi Kable mai siffofin Tsarin Kable Mai Tsarki: Tsarin kable, za a zaba a mm² ko AWG, tare da zaɓuwar kofin ko aluminium. Kable Mai Tsarki Da Su Kaɗa: Adadin kable masu tsarki da suka kaɗa; yana ƙasance tsaron kable. Zaɓuwar Kofin: Kofin ko aluminium, wanda ya haɗa da tsaron kable. Tsawon Kable Mai Yawa: Tsawon kable mai yawa (m/ft/yd), yawanci tsawon daɗi amma yana da muhimmanci. Tsarin Kable Mai Yawa: Tsarin kable mai yawa (mm² ko AWG). Kable Mai Yawa Da Su Kaɗa: Adadin kable mai yawa da suka kaɗa. Abubuwan Da Ake Bayyana Karamin karamin uku (Isc, kA) Karamin karamin mai yawa (Isc1, kA) Karamin karamin mai girma (Ip, kA) Tsaron kofin (Zeq, Ω) Kwara karamin karamin (Ssc, MVA) Bayanan Standards: IEC 60865, IEEE C37.100 An gina wannan alat don malamai da ake kula da abubuwan da suka sauki, mai kula da abubuwan da suka sauki, da kuma masu duba ingantaccen karamin karamin a wurin maimaitar mai yawa.
Aika tambaya
Kwamfuta
Samun IEE Business Application
Yi amfani da IEE-Business app don samun abubuwan aikin, samun halayyin, haɗi da malamai, kuma kai tsauraran takaiddun kasoshin duka lokaci, duka wurin—dole bai karfin takamaltar hulɗin ku na alintakargida da kasuwanci.