Hoc instrumentum computat valores capacitatorum operativorum et initiaticorum necessarios ad operandum motorem inductionis triphasicae per potentiam monophasicam. Id aptum est pro motoribus parvis (< 1.5 kW), cum potencia output reducitur ad 60–70%.
Input rated power motoris, potentia monophasica, et frequentia ut automaticae computentur:
Capacitor operativus (μF)
Capacitor initiaticus (μF)
Supportat unitates kW et hp
Calculatio bidireccional in tempore reali
Capacitor Operativus: C_run = (2800 × P) / (V² × f)
Capacitor Initiaticus: C_start = 2.5 × C_run
Ubi:
P: Potentia motoris (kW)
V: Potentia monophasica (V)
f: Frequens (Hz)
Exemplum 1:
1.1 kW motor, 230 V, 50 Hz →
C_run = (2800 × 1.1) / (230² × 50) ≈ 11.65 μF
C_start = 2.5 × 11.65 ≈ 29.1 μF
Exemplum 2:
0.75 kW motor, 110 V, 60 Hz →
C_run = (2800 × 0.75) / (110² × 60) ≈ 2.9 μF
C_start = 2.5 × 2.9 ≈ 7.25 μF
Solum aptum pro motoribus parvis (< 1.5 kW)
Potentia output cadit ad 60–70% originalis
Utere capacitoribus nominatis ad 400V AC vel superiore
Capacitor initiaticus debet disjungi automaticamente
Motor debet coniungi in configuratione "Y"