| Marke | ROCKWILL |
| Serie | JDS |
Product Overview
As a pioneer and the first dedicated original equipment manufacturer (OEM) in China's neutral grounding transformer industry, we have laid the original benchmark for the industry's development with our profound technical strength accumulated through decades of intensive cultivation. From the independent R&D of core technologies to large-scale mass production, we have built a full-process independently controllable system. Relying on our stable and leading product performance and unparalleled reliability, we have become a preferred partner in the field of power grid construction.
Rockwill delivers reliable and high-performance earthing transformers designed for 66kV power systems. Our oil-immersed transformers are engineered to provide stable neutral grounding solutions while ensuring operational safety and system protection. Manufactured in compliance with international standards including IEC and GB, these transformers incorporate premium materials and rigorous quality control throughout production.
Basic Info.
Some of these earthing transformers cover voltage levels including:3.3kV / 6kV / 11kV / 15kV / 20kV / 22kV / 30kV / 33kV / 34.5kV / 36kV / 44kV / 66kV / 88kV / 110kV / 132kV / 145kV / 150kV / 220kV / 275kV / 330kV / 400kV, etc. The current withstand time ranges from 1s, 2s, 3s, 5s, 6s, 8s, 9s, 10s, 30s, 60s, 1hour to 2hours, and customization is available.
Parameter |
Detail |
Parameter |
Details |
Cooling Method |
Oil-Immersed Type Transformer |
Core |
Core-type Transformer |
Certification |
ISO9001 |
Usage |
Power Transformer |
Frequency Characteristics |
Power Frequency |
Shape of Core |
Ring |
Brand |
Rockwill |
Item |
3 Phase Oil Type Earthing 6kv Power Transformer |
Primary Voltage |
66kv |
Secondary Voltage |
0.4kv |
Rating Capacity |
350kVA |
Transformer |
66kv Power Transformer |
Iron Core |
Wounded Core |
Coil Structure |
Isolation |
Loss |
Low Losses |
Tank Design |
Sealed |
Specification |
CTQC type tested |
Transport Package |
Wooden Case |
Origin |
Zhejiang China |
Trademark |
Rockwill |
Key Features
Voltage Class: 66kV system voltage (200 BIL)
Capacity Range: Standard units from 100kVA to 10,000kVA
Winding Configuration: Optimized zigzag (ZNyn) design
Cooling System: ONAN/OFAF cooling options
Insulation: Mineral oil or synthetic ester fluid
Construction:
Corrugated tank or radiator cooling
Hermetically sealed or conservator tank options
CRGO silicon steel core
Copper/aluminum windings
Technical Advantages
Enhanced Safety: Built-in Buchholz relay and pressure relief device
Low Impedance: Zero-sequence impedance <15Ω for effective fault current management
Durability: Corrosion-resistant paint system for outdoor installations
Efficiency: Reduced no-load losses through optimized core design
Flexibility: Off-circuit tap changer (±5% in 2.5% Steps)
Typical Applications
Utility Networks:
Neutral grounding for 66kV transmission systems
Arc suppression coil connections
Resistance grounding systems
Industrial Plants:
Petrochemical facilities
Mining operations
Steel manufacturing plants
Renewable Energy:
Wind farm collector stations
Solar PV substations
Hydroelectric plants
Performance Specifications
Temperature Range: -30°C to +40°C Ambient
Humidity: ≤95% Monthly Average
Altitude: Up to 2000m ASL
Sound Level: ≤75dB at 1m
Efficiency: ≥99.2% at Full Load
Testing Protocol
All units undergo comprehensive testing including:
Zero sequence impedance measurement
Induced overvoltage test (260Hz)
Lightning impulse test (350kV)
Temperature rise test (65K max.)
Oil dielectric strength test (≥50kV)
Service Conditions
Suitable for indoor/outdoor installation
Wind resistant up to 35m/s
Non-explosive environments
Seismic capability: 0.3g horizontal acceleration
Application Fields
66kV/88kV/110kV/132kV Power Distribution Network Construction
New Energy Power Plants (e.g., Wind Power/Photovoltaic)
Power Distribution Stations in Large Industrial Parks
Railway Traction Power Supply Systems
Urban Power Grid Upgrading and Renovation Projects
High-Voltage Power Supply Systems for Industrial and Mining Enterprises
Grounding Protection Projects of Regional Substations
Eine Erdungs-/Grundungstransformatoren ist eine spezielle Art von Transformator, der künstlich einen neutralen Punkt für unverdichtete oder niederstromige erdete Stromsysteme erstellt. Er konstruiert einen Erdkreislauf durch ein spezifisches Wickeldesign mit zwei Kernfunktionen: Erstens, um einen Niederimpedanzweg für Nullfolgenstrom im System bereitzustellen, um sicherzustellen, dass der Fehlerstrom den Betriebs-Schwellwert des Relaisschutzgeräts erreicht, wenn ein Einphasen-Erdschluss auftritt, was eine schnelle Fehlerortung und -isolierung ermöglicht; zweitens, um die Spannungsbalance des Systems aufrechtzuerhalten, das Übermaß an Spannungsanstieg der nichtfehlerhaften Phasen während eines Fehlers zu unterdrücken und die Isolierungssicherheit der Netzausrüstung zu schützen. Im Gegensatz zu normalen Leistungstransformatoren besteht seine Hauptfunktion darin, einen "Erdkreislauf" zu konstruieren, anstatt eine "Spannungsumwandlung" vorzunehmen, und er wird in der Regel nach kurzzeitiger Lastkapazität anstelle einer kontinuierlichen Betriebskapazität entworfen.
Die Unterschiede zwischen den beiden rühren von der wesentlichen Differenz in der funktionalen Positionierung her, die sich in drei Aspekten speziell widerspiegelt: ① Verschiedene Kernfunktionen: Gewöhnliche Starkstromtransformator konzentrieren sich auf Spannungsumwandlung und Energieübertragung, während Erdungs-/Pegeltransformator auf die Konstruktion von Neutralpunkten und die Bereitstellung von Fehlerstromwegen abzielen; ② Verschiedene Kapazitätskalibrierungen: Gewöhnliche Starkstromtransformator sind mit einer kontinuierlichen Betriebskapazität (langfristige Lastkapazität) gekennzeichnet, während Erdungs-/Pegeltransformator mit einer kurzzeitigen Nennleistung (Kapazität, die innerhalb einer bestimmten Zeit basierend auf Fehlerstrom und Standzeitaufnahme, z.B. 30 Sekunden, getragen werden kann) markiert sind; ③ Verschiedene Wicklungsdesigns: Erdungs-/Pegeltransformator verwenden meist spezielle Wicklungsstrukturen wie Zickzack (ZN), während gewöhnliche Starkstromtransformator hauptsächlich konventionelle Wicklungen wie Stern und Delta verwenden, und Erdungs-/Pegeltransformator haben in der Regel kein traditionelles Spannungsverhältnis.