| العلامة التجارية | ROCKWILL |
| سلسلة | DKSC |
| الجهد المقنن | 35 kV |
| زمرة التوصيل | Z (zigzag) / ZNyn11 |
| نطاق السعة المقننة | 100 – 5,500 kVA |
| التردد المقنن | 50 / 60 Hz |
As a trailblazer and the first dedicated original manufacturer in China’s earthing transformer sector, decades of focused technical advancement have endowed us with robust capabilities and even laid the foundational standards for industry development. Spanning from breakthroughs in core R&D to large-scale production and delivery, we’ve built an end-to-end independent ecosystem. Boasting leading and stable product performance paired with exceptional reliability, we stand as a trusted partner for power grid construction projects.
Rockwill 35kV 36kV 44kV 66kV Three Phase Cast Resin Dry Type Zigzag (Z-Type) Grounding Transformer provide a reliable artificial neutral grounding solution for power systems where the neutral point is unavailable, such as delta-connected or ungrounded star systems. These specialized transformers create a stable neutral point for connecting arc suppression coils (Petersen coils) or neutral grounding resistors, ensuring safe and effective system grounding.
Additionally, Rockwill grounding transformers can be equipped with a secondary winding to supply auxiliary power, offering a cost-effective alternative to separate station transformers.
Key attributes
Some of these earthing transformers cover voltage levels including:3.3kV / 6kV / 11kV / 15kV / 20kV / 22kV / 30kV / 33kV / 34.5kV / 36kV / 44kV / 66kV / 88kV / 110kV / 132kV / 145kV / 150kV / 220kV / 275kV / 330kV / 400kV, etc. The current withstand time ranges from 1s, 2s, 3s, 5s, 6s, 8s, 9s, 10s, 30s, 60s, 1hour to 2hours, and customization is available.
application |
power |
coil structure |
toroidal |
place of origin |
china |
model number |
DKSC10-400/35 |
off-load loss |
1500w |
neutral point current |
20A |
phase |
three |
coil number |
autotransformer |
brand name |
rockwill |
rated capacity |
400kVA |
zero sequence impedance (zn) |
170 |
Key Applications
Substations and distribution networks (35kV and below)
Industrial power systems requiring a neutral grounding point
Renewable energy plants (wind/solar farms) with ungrounded sources
Rated Capacity: 100kVA to 5500kVA
Rated Voltage: Up to 35kV
Insulation Class: Class F (compliant with IEC 60076)
Connection Type: Zigzag (Z-Type) for optimal zero-sequence performance
Zero-Sequence Impedance: Low impedance (~10Ω) for efficient fault current handling
Advanced Zigzag Winding Design – Unlike conventional transformers, Rockwill’s Z-Type configuration ensures zero-sequence flux circulates within the core, minimizing impedance and enhancing grounding performance.
Full-Capacity Arc Suppression Support – Compatible with 90-100% rated capacity arc suppression coils, far exceeding the 20% limit of standard transformers.
Dual-Purpose Functionality – Optional secondary winding allows the transformer to supply station power, reducing the need for additional equipment.
Dry-Type, Cast Resin Construction – Maintenance-free, flame-resistant, and suitable for harsh environments.
High Efficiency & Reliability – Engineered for stable operation under fault conditions, preventing magnetic saturation.
IEC 60076 Compliant – Manufactured to international standards for global reliability.
Rockwill grounding transformers deliver superior performance, safety, and cost savings by combining neutral grounding and auxiliary power supply in a single unit. Their optimized design ensures enhanced system protection, reduced downtime, and lower installation costs—making them the ideal choice for modern power systems.
تعتمد سيناريوهات التطبيق بشكل كبير على مستويات الجهد وأنواع العزل، مع التحويلات المحددة كالتالي:
نعم. تتوفر محولات التأريض Rockwill بنسختين: المغمورة بالزيت والجافة من الراتنج المصبوب. تناسب الوحدات المغمورة بالزيت التطبيقات الخارجية عالية السعة. تُفضل طرازات الراتنج المصبوب الجاف للمواقع الداخلية ذات متطلبات السلامة من الحرائق الصارمة (المحطات الفرعية، مراكز البيانات). يمكن تجهيز كلا النوعين بملف ثانوي مساعد، ومجموعات مراقبة محولات الجهد/محولات التيار.
يتوفر اختبار المراقبة بواسطة طرف ثالث عند الطلب. يمكننا تنسيق جدول اختبارات المصنع لاستيعاب المفتشين من المشتري، أو المستشار الهندسي، أو جهة إصدار الشهادات، أو مرفق الطاقة.
تشمل اختبارات المراقبة عادةً مقاومة اللف، والتحقق من مجموعة المتجهات، ومقاومة العزل، وقياس معاوقة التسلسل الصفري، واختبار تحمل تردد القدرة، واختبارات التفريغ الجزئي. تتبع جميع إجراءات الاختبار معايير IEC، وسيتم اعتماد بيانات الاختبار الكاملة من كلا الطرفين.
إذا طلب العميل إجراء اختبارات خاصة إضافية تتجاوز نطاق الاختبارات الروتينية القياسية، فيمكننا تقييم الجدوى والجدول الزمني والتكلفة الإضافية بشكل منفصل مسبقاً.
يُدرج توجيه التكليف عن بُعد كخدمة قياسية. ويُعد حضور المهندس في الموقع خدمة اختيارية يمكن إضافتها بموجب العقد.
عند حضور المهندسين إلى الموقع، سيقومون بفحص التركيبات الميكانيكية، وتوصيل التأريض، وجودة أطراف الكابلات، وتوصيلات المستشعرات، والتنسيق مع فريق الحماية للتحقق من منطق حلقة التسلسل الصفري.
كما سيقومون بمقارنة ممانعة التسلسل الصفري المقاسة بالقيم المصنعية، وتوجيه خطوات التغذية بالطاقة، وتسجيل بيانات التشغيل الأولية.
لا تغطي الخدمة في الموقع الأعمال الإنشائية، أو تمديد الكابلات، أو برمجة مرحلات الحماية، ما لم تُدرج هذه العناصر الإضافية بوضوح في نطاق الخدمة.
التعديلات الطفيفة مثل تعديل جهد الملف المساعد، أو تكوين المستشعر، أو ملحقات الغلاف تكون ممكنة عادةً قبل بدء عملية الصب.
بمجرد اكتمال عملية صب ومعالجة ملفات الإيبوكسي، لا يمكن تغيير المعلمات الكهربائية الأساسية بما في ذلك ممانعة التسلسل الصفري ومجموعة المتجه.
إذا تغير مخطط تأريض الشبكة، أو تيار العطل المطلوب، أو مدة التحمل لفترة قصيرة بعد عملية الصب، فسيكون من الضروري إعادة التصميم وإعادة التصنيع.
يجب تقديم أي طلب لتغيير التصميم في أقرب وقت ممكن، وسيقوم فريقنا بإصدار ورقة بيانات فنية محدثة، ومراجعة للتكلفة وموعد التسليم للموافقة عليها.