ROCKWILL H59 Grounding Transformer Solution: Zig-Zag Winding & Smart Monitoring for Neutral Grounding Systems
Mga Pagnanais na Application:
Pagsasalamin ng neutral point sa mga hindi nagsasariling grounded o resonant grounded na sistema, paglimita ng single-phase ground fault current, pagpapahina ng overvoltage ng sistema.
I. Mga Solusyon sa Core Design
- Customized Grounding Transformer
- Itinayo sa H59 oil-immersed transformer platform, gamit ang high-voltage side na may Zig-Zag windings o Yn-d connection upang magbigay ng matatag na neutral grounding impedance.
- Nakakumpili sa IEC 60076 at NF C52-112 standards, may disenyo ng insulation strength na maaaring tanggihan ang surge ng ground fault current.
- Pagkakataon ng Key Parameters
|
Parameter
|
Value/Specification
|
|
Rated Voltage
|
System voltage adaptation (6kV/10kV/20kV/33kV)
|
|
Short-Time Overload
|
Withstands 10–20× rated current for 10 seconds
|
|
Zero-Sequence Impedance
|
Customized per system capacitive current (Typical: 40Ω–100Ω)
|
|
Connection Method
|
Znyn11 or YNd11
|
- Paggamit ng Paraan ng Grounding
- Resistance Grounding: Secondary side connected to stainless steel grid resistor cabinets, limiting fault current to a safe range (Optional: 200A–2000A).
- Arc Suppression Coil Grounding: Paired with automatic tuning arc suppression coils to extinguish fault-point arcs.
II. Mga Teknikal na Advantages
- Matatag na Structure & Proteksyon
- Fully sealed oil tank: IP23 protection rating, suitable for outdoor installation (–25℃ to +50℃).
- Epoxy resin bushings: High-voltage side uses 33kV-grade T-type cable terminations (EPDM material), ensuring insulation reliability in humid environments.
- Intelligent Monitoring System
- Integrated DGPT2/DMCR protection relays for real-time monitoring of:
✓ Neutral point current/voltage
✓ Oil temperature (55℃ max. temperature rise)
✓ Oil level & pressure transients
✓ Fault gases (H₂, CH₄) content.
- High Efficiency & Energy Saving
- Copper windings + ONAN cooling: No-load loss ≤0.2% of rated capacity (e.g., 1300W for 630kVA).
- Efficiency >98.5% (at full load, cosφ=1), meeting green grid standards.
III. Mga Serbisyo ng Engineering Adaptation
- Customized Configuration
- Bushings creepage distance customized for altitude (>1000m requires reinforced insulation) and pollution levels.
- Optional add-ons:
- 5-position non-excitation tap changer (±2×2.5%)
- Stainless oil valves & anti-vibration roller bases.
IV. Typical Case Parameters
|
Capacity (kVA)
|
System Voltage (kV)
|
Zero-Seq. Impedance (Ω)
|
Resistor Current (A)
|
Protection Device
|
|
300
|
20
|
60
|
400
|
DGPT2 + Thermostat
|
|
500
|
33
|
85
|
800
|
DMCR + Gas Relay
|
V. Service Commitment
- 10-year warranty: Lifelong maintenance for seals and windings.
- 48-hour response: Technical support hotline +86 577 27869969.
- Documentation provided: Grounding calculation reports, type test certificates (including temperature rise & short-circuit tests).
Note: This solution requires user-provided parameters (e.g., system short-circuit capacity, capacitive current) for precision engineering. Rockwill engineers will customize designs accordingly.