Indonesia's Seismic-Resilient High Voltage Disconnect Switch Solution for Earthquake-Prone Grids

Vziman
4yrs + staff 10000+m² US$0+ China

1. Project Background

Indonesia is situated on the Pacific Ring of Fire, experiencing frequent seismic activity. According to warnings from the Indonesian Agency for Meteorology, Climatology, and Geophysics (BMKG), islands such as Sumatra, Java, and Sulawesi face threats from large-scale megathrust earthquakes, posing severe risks to power infrastructure.

Traditional ​High Voltage Disconnect Switches, due to their high structural rigidity and weak seismic resistance, are prone to insulator fractures, conductor displacement, or mechanical linkage failures during earthquakes, leading to grid paralysis. For example, the 2018 M7.4 Sulawesi earthquake caused massive damage to substation equipment. Thus, developing ​High Voltage Disconnect Switches​ adapted to high-intensity seismic zones has become an urgent need for Indonesia's power security.

​2. Solution

2.1 ​Core Seismic Design Technology​​

  • Multi-stage Shock Absorption System:
    Adopts a "damper + disc spring" composite structure for ​High Voltage Disconnect Switches. Vertical bidirectional dampers absorb seismic energy, while transverse buffer disc spring sets disperse shear forces, reducing resonance risks. For instance, adding disc spring arrays to ​High Voltage Disconnect Switch​bases can offset up to 30% of lateral displacement.
  • Friction Pendulum Isolation Bearings (FPS):
    Installs curved sliding rail friction pendulum systems at ​High Voltage Disconnect Switch​ equipment bases, dissipating energy through sliding friction (friction coefficient optimized to 0.04) with automatic resetting.

2.2 ​Structural Reinforcement & Smart Early Warning Integration

  • Equipment Coupling Optimization:
    For ​High Voltage Disconnect Switches​with multi-section insulators (e.g., GW9-10 type), flexible conductors replace rigid connections to minimize seismic coupling effects. Metal reinforcement rings are added to insulator roots to prevent brittle fractures in these switches.
  • Seismic Early Warning Linkage:
    Integrates with earthquake early warning systems, enabling automatic power-off protection for ​High Voltage Disconnect Switches​ seconds before strong quakes.

​2.3 Localized Adaptation & Maintenance Assurance

  • Materials & Craftsmanship:
    High Voltage Disconnect Switch​cabinets use high-ductility steel, and critical bolt connections incorporate rubber shock-absorbing pads.
  • Modular Maintenance Design:
    Shock-absorbing components in ​High Voltage Disconnect Switches​ feature detachable modules for rapid replacement.

​3. Achieved Outcomes

3.1 ​Significantly Enhanced Seismic Performance
Laboratory simulations confirm optimized ​High Voltage Disconnect Switches​withstand IX intensity, with insulator root stress reduced by >50%.

3.2 ​Improved Grid Reliability
Early warning linkage shortens earthquake-induced blackout recovery for ​High Voltage Disconnect Switch​-equipped substations to ≤2 hours.

​3.3 Technology Promotion & Cost Efficiency
The ​High Voltage Disconnect Switch​solution is incorporated into Indonesia’s SNI Seismic Building Standards.

06/03/2025
Recommended
Analysis of Advantages and Solutions for Single-Phase Distribution Transformers Compared to Traditional Transformers
1. Structural Principles and Efficiency Advantages​1.1 Structural Differences Affecting Efficiency​Single-phase distribution transformers and three-phase transformers exhibit significant structural differences. Single-phase transformers typically adopt an E-type or ​wound core structure, while three-phase transformers use a three-phase core or group structure. This structural variation directly impacts efficiency:The wound core in single-phase transformers optimizes magnetic flux distribution, ​
Integrated Solution for Single Phase Distribution Transformers in Renewable Energy Scenarios: Technical Innovation and Multi-Scenario Application
1. Background and Challenges​The distributed integration of renewable energy sources (photovoltaics (PV), wind power, energy storage) imposes new demands on distribution transformers:​Volatility Handling:​​Renewable energy output is weather-dependent, requiring transformers to possess high overload capacity and dynamic regulation capabilities.​Harmonic Suppression:​​Power electronic devices (inverters, charging piles) introduce harmonics, leading to increased losses and equipment aging.​Multi-Sc
Single-Phase Transformer Solutions for SE Asia: Voltage, Climate & Grid Needs
1. Core Challenges in the Southeast Asian Power Environment​1.1 ​Diversity of Voltage Standards​Complex voltages across Southeast Asia: Residential use often 220V/230V single-phase; industrial zones require 380V three-phase, but non-standard voltages like 415V exist in remote areas.High-voltage input (HV): Typically 6.6kV / 11kV / 22kV (some countries like Indonesia use 20kV).Low-voltage output (LV): Standardly 230V or 240V (single-phase two-wire or three-wire system).1.2 ​Climate and Grid Condi
Pad-Mounted Transformer Solutions: Superior Space Efficiency and Cost Savings over Traditional Transformers
1.Integrated Design & Protection Features of American-Style Pad-Mounted Transformers1.1 Integrated Design ArchitectureAmerican-style pad-mounted transformers employ a combined design integrating key components - transformer core, windings, high-voltage load switch, fuses, arresters - within a single oil tank, using transformer oil as both insulation and coolant. The structure consists of two main sections:​Front Section:​​High & Low Voltage Operation Compartment (with elbow plug-in conne
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.