ZHW Series HV Gas insulation switchgear (GIS)

  • ZHW Series HV Gas insulation switchgear (GIS)
  • ZHW Series HV Gas insulation switchgear (GIS)
  • ZHW Series HV Gas insulation switchgear (GIS)

Key attributes

Brand ROCKWILL
Model NO. ZHW Series HV Gas insulation switchgear (GIS)
Rated voltage 72.5kV
Rated normal current 2000A
Rated frequency 50/60Hz
Rated peak value withstand current 100kA
Rated short-time withstand current 40kA
Series ZHW Series

Product descriptions from the supplier

Description

Overview

ZHW-145 (H) 145kV HGIS is an efficient equipment suitable for power transmission and distribution scenarios, with significant advantages in space utilization, installation efficiency, performance stability, and other aspects.
In terms of space saving, compared with AIS substations, it can save 60%-70% of the floor area, which can effectively alleviate the current tight land resource problem, and is especially suitable for deployment in areas with limited land resources.
It has outstanding installation convenience. The equipment is transported in the form of complete interval units, and all components have been debugged and tested in the factory. On-site, only a small amount of line connection and routine testing are required, and the on-site installation time for a single interval is ≤16 hours, which significantly shortens the project cycle.
The performance is stable and reliable. The core component, the circuit breaker, adopts a horizontal arrangement with a low center of gravity, excellent stability and seismic resistance. It has passed the AG5 test and is suitable for earthquake-prone areas. At the same time, it can operate stably in extremely harsh environments such as sandstorms and heavy pollution, adapting to various complex working conditions.
Maintenance and expansion are convenient. It adopts anchor bolt fixing and overhead incoming and outgoing line design, with independent intervals. The replacement time for a single interval is ≤4 hours, avoiding long-term power outages caused by GIS substation failures. The expansion and reconstruction of substations are also simpler, especially suitable for the transformation needs of AIS substations.
The whole life cycle cost is lower. Compared with GIS and AIS, it has less maintenance work, lower construction difficulty, shorter construction period, convenient maintenance, and low equipment operation cost, which can reduce long-term investment for users.

Features

  • Small in Size To compare with AIS Substation, it can save 60 - 70% of the floor area, best way for saving current increasingly tense land resources;
  • Fast Way To transport the Combined bay. All HGIS components have been debugged and tested in the Factory. Only a few line connections and routine tests are required on - site, therefore, the on - site installation time of single bay can be ≤10h; 
  • Stability in Performance The Circuit Breaker is the HGIS core component, which is horizontally arranged, with low center of gravity, better stability and better seismic performance. It is especially suitable for earthquake - prone areas (Have accepted and passed the ACS test). The Circuit Breaker can be used in extremely harsh environments (Sandstorm, heavy pollution, etc.), thanks for its fully enclosed transmission way.
  • Convenience in Replacement It is designed solely with anchor bolt fixing and overhead incoming and outgoing lines, with independent bays, therefore, the replacement of single bay can be completed within 4h. Also not be troubled as GIS Substation, which can be troubled by the long power outage time caused by GIS Substation failure, the transformation and expansion of the Substation is relatively simple and convenient, especially suitable for the AIS Substation. It only needs simple civil foundation work with small investment, so it's worth it;
  • Reliable in Quality The HGIS is specialized designed is relative perfectly, with SF6 gas insulation for its excellent insulation and breaking performance.
  • Lower Life - cycle Costs Refer to GIS and AIS, the HGIS has the multi features, such as minimum maintenance workload, minimum construction difficulty, shortest construction time, minimum overhaul difficulty, lower equipment cost, lower operation cost and shorter construction period for reconstruction and expansion. 

Technology Parameters

If you need to know about more parameters , Please check the model selection manual.

Documentation Resource Library
Restricted
ZHW-145-HGIS-Catalog
Catalogue
English
Consulting
Consulting
FAQ
Q: What is the insulation principle of gas-insulated switches?
A:

Insulation Principle:

  • In an electric field, the electrons in SF₆ gas molecules are slightly displaced from the nuclei. However, due to the stability of the SF₆ molecular structure, it is difficult for electrons to escape and form free electrons, resulting in high insulation resistance. In GIS (Gas-Insulated Switchgear) equipment, the insulation is achieved by precisely controlling the pressure, purity, and electric field distribution of the SF₆ gas. This ensures a uniform and stable insulating electric field between the high-voltage conductive parts and the grounded enclosure, as well as between different phase conductors.

  • Under normal operating voltage, the few free electrons in the gas gain energy from the electric field, but this energy is not sufficient to cause collision ionization of the gas molecules. This ensures the maintenance of the insulating properties.

Q: What are the characteristics of GIS equipment?
A:

Due to the excellent insulation performance, arc extinguishing performance and stability performance of SF6 gas, GIS equipment has the advantages of small footprint, strong arc extinguishing ability and high reliability, but the insulation ability of SF6 gas is greatly affected by the uniformity of the electric field, and it is easy to have insulation abnormalities when there are tips or foreign objects inside the GIS.

GIS equipment adopts a fully enclosed structure, which brings the advantages of internal components without environmental interference, long maintenance cycle, low maintenance workload, low electromagnetic interference, etc., while also having problems such as complex single overhaul work and relatively poor detection methods, and when the closed structure is eroded and damaged by the external environment, it will further bring a series of problems such as water ingress and air leakage.

Q: What is the principle of the protection function of gas-insulated switchgear?
A:

Protection Function Principles:

  • GIS equipment is equipped with various protection functions to ensure the safe operation of the power system.

Overcurrent Protection:

  • The overcurrent protection function monitors the current in the circuit using current transformers. When the current exceeds a predefined threshold, the protection device triggers the circuit breaker to trip, cutting off the faulty circuit and preventing damage to the equipment due to overcurrent.

Short-Circuit Protection:

  • The short-circuit protection function quickly detects short-circuit currents when a short-circuit fault occurs in the system and causes the circuit breaker to act rapidly, protecting the power system from damage.

Additional Protection Functions:

  • Other protection functions, such as ground fault protection and overvoltage protection, are also included. These protection functions use appropriate sensors to monitor electrical parameters. Once any abnormality is detected, the protection actions are immediately initiated to ensure the safety of the power system and equipment.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

Related Solutions

Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.