Search


VANP 2P Voltage – current protector

  • VANP 2P Voltage – current protector
  • VANP 2P Voltage – current protector
  • VANP 2P Voltage – current protector

Key attributes

Brand Xinyouxiang
Model NO. VANP 2P Voltage – current protector
Rated voltage AC220V
Rated normal current 40A
Rated frequency 50/60Hz
Series VANP
Description

Product Introduction: VANP-2P is an intelligent 2P overvoltage and undervoltage protection device suitable for single-phase AC 220V/50-60Hz power grid environment. It integrates overvoltage protection, undervoltage protection, and overcurrent protection functions. By accurately monitoring the line voltage and current, it quickly acts and cuts off the circuit when abnormal situations beyond the safe range are detected; After the power grid parameters return to normal, it can automatically reset and connect according to the set time, providing continuous security for the backend load.

VANP-2P self resetting overvoltage and undervoltage protector product features:
1. Precise monitoring and rapid response:
Adopting high-precision voltage detection circuit (with an error not exceeding 2% of the total range), it can sensitively perceive small changes in grid voltage. When the abnormal voltage reaches the set threshold (overvoltage ≥ 230V, undervoltage ≤ 140V), the device can quickly cut off the power supply within the set tripping delay time (adjustable from 0.1 seconds to 30 seconds), effectively suppressing the impact of abnormal voltage on sensitive equipment.
2. Intelligent recovery management:
Different from disposable protective devices, it has intelligent self reset function. After the grid voltage stabilizes and returns to the safe range (140V-210V), the device will automatically close again according to the preset reset delay time (adjustable from 1 second to 500 seconds) to restore power supply. This design not only avoids frequent disconnections caused by brief fluctuations in the power grid, but also ensures the stability of power supply recovery.
3. Integrated overcurrent protection:
In addition to voltage protection, the integrated overcurrent protection function (current setting range 1~63A) provides more circuit safety protection and prevents accidents caused by line overload or short circuit.
4. High reliability and long lifespan design:
The core components and structural design focus on durability, with an electrical lifespan of up to 100000 operations and a mechanical lifespan of up to 1000000 operations, reducing maintenance costs and replacement frequency, making it suitable for situations that require long-term reliable operation.
5. Flexible parameter configuration:
Users can flexibly set the overvoltage and undervoltage action threshold, as well as the tripping delay, based on the actual characteristics of the electrical equipment and the power grid conditions
Realize personalized customization of protection strategies with delay time for interval and reset

Technical data


Rated supply voltage

AC 220V

Operation voltage range

AC 80V - 400V (single phase)

Rated frequency

50/60Hz

Electric current (>A) setting range

1 - 40/63A

Overvoltage (>U) setting range

230 - 300V

Undervoltage (<U) setting range

210 - 140V

Rated current

40/63A (subject to product label)

>U and <U trip delay

0.5S

Reset/start delay

1 - 600S

Voltage measurement accuracy

2% (Not exceeding 2% of the overall range)

Rated insulation voltage

400V

Output contact

1NO

Electrical life


Mechanical life


Protection degree

Ip20

Pollution degree

3

Altitude

≤2000m

Operating temperature

-50°C - 55°C

Humidity

≤50% at 40°C (without condensation)

Storage temperature

-30°C - 70°C

Documentation Resource Library DIN Rail Voltage-Current Protector

VANP-2P-catalog
Restricted
VANP-2P-catalog VANP-2P-catalog
Catalogue
English
PDF

Frequently asked questions

The overvoltage protection setting range is 230V-300V, with a factory default of 280V; the undervoltage protection setting range is 140V-210V, with a factory default of 160V; the overcurrent protection setting range is 1A-40A/63A (corresponding to the rated current specification), with a factory default of 40A/63A; The overvoltage/undervoltage trip delay is both 0.5S, and the overcurrent trip delay is 5S.

The operation needs to be achieved through the device buttons. Click the SET button to enter the parameter setting menu, short press the plus or minus button to fine tune the values, and long press the plus or minus button to quickly adjust; After all parameter settings are completed, press and hold the SET button for 5 seconds to save and take effect; The overvoltage, undervoltage, and overcurrent protection functions support independent setting to OFF state, and the number of continuous overcurrent protection times can be selected between A01-A20/OFF

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: 100 Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Medium and High Voltage Switchgear/Low Voltage Electrical Components/Instrument Transformers and Sensors/Transformer and Switchgear Parts/Construction Equipment and Tools/Electrical Manufacturing and Factory Automation/Cable Accessories/Electrical Panel and Controlgear/Power Quality Equipment
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register