UL 15-500kVA oleo pleno unipolare transformator in stativa

  • UL 15-500kVA Oil Filled Single Phase Pad Mounted Transformer

Attributa principalia

Marca Vziman
Numerus Modeli UL 15-500kVA oleo pleno unipolare transformator in stativa
Frequenta nominata 50/60Hz
Capacitas nominata 500kVA
Tensio primum 33kV
Series ZGS

Descriptiones productorum a fornitori

Descriptio

Descriptio:

Hoc est transformator oleo-immersus uniphasis certificatus a UL, specialiter designatus ad installationem extra domum. Conformatur UL 1561 (Transformator siccus) vel UL 1562 (Transformator oleo-immersus) standardibus, aptus pro capacitatis rangis de 15-500kVA, cum classibus voltuarum ab 7.2kV-34.5kV (latus alti-voltus) et 120-600V (latus bassi-voltus). Eius characteristicae includunt:

 

  • Forma Structurae: Adoptat designatum Pad-Mounted (caesaei formae fundamento impositam) cum structura totaliter sigillata, attingens protectionem IP65/66, et potest directe collocari super fundamenta concreta.
  • Medium Insulationis: Utitur oleo minerali vel oleo silicico alti-puncti flammativitatis ut media insulatoria et refrigeratoria, cum praestatione protectionis contra incendium et explosionem (conformans standardibus UL 1203).
  • Adaptatio Voltus: Latus alti-voltus supportat plures classes voltuarum sicut 7.2kV, 12.47kV, 13.8kV, 25kV, 34.5kV, etc., dum latus bassi-voltus emit 120V/240V (uniphasis tri-filis) vel 208V/480V/600V (triphasis quadri-filis).

Functiones Principales:

  • Conversio Voltus: Reducit medium voltum (exempli gratia 7.2kV) ad bassum voltum (exempli gratia 240V) ad satisfaciendum demandatis electricitatis aedificiorum domesticorum, commercialium, vel parvorum industrialium.
  • Isolatio Securitatis: Isolat latera alti-voltus et bassi-voltus per designatum insulationis oleo-immersam ad meliorem securitatem.
  • Protectio Supercargationis: Equipatur controller temperaturae et valva relevari pressionis, quae automaticiter interrumpit electricitatem quando temperatura olei excedit valor fixus (exempli gratia 80°C) vel pressio interna est anormalis.
  • Adaptatio Ambientalis: Tolerat ambientes duros sicut altas temperaturas, humiditatem, et pulverem, apta pro operatione extra domum longaevi.

Scenarii Applicationis Typici:

  • Distributio Electricitatis Domesticarum: Procurat uniphasis 240V electricitatem pro villis singulis et regionibus domesticis, supportans dispositiva magni potentiae sicut aeratores et calentores aquae.
  • Facilitates Commercialis: Procurat 120V/240V electricitatem pro minimis mercatoribus, parvis centris emptionum, stationibus refectionis, etc., satisfaciendo necessitatibus illuminationis et systematis numerandorum.
  • Parvae Cargas Industrialis: Procurat electricitatem pro agris et parvis plantis processionalibus, sicut motricibus pompae aquae et motoribus parvis.
  • Accessus Energiae Renovabilis: Servit ut dispositivum elevandi vel deprimendi in projectis photovoltaicis et eolicis, adaptans ad scenaria generationis distributae electricitatis.

Parametri:

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 10000m² Numerus omnium laborantium: 300 Summa Annua Exportatio (USD): 150000000
Locus Operis: 10000m²
Numerus omnium laborantium: 300
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum