RNV-A1-12D-1250A SF6 alta tensio gas insulata inflata armarii circuit disjunctoris

  • RNV-A1-12D-1250A SF6 High Voltage Gas Insulated Inflatable Cabinet Circuit Breaker

Attributa principalia

Marca Switchgear parts
Numerus Modeli RNV-A1-12D-1250A SF6 alta tensio gas insulata inflata armarii circuit disjunctoris
Votum nominatum 12kV
currus electricus nominatus 1250A
Frequenta nominata 50Hz
Series RNV-A1

Descriptiones productorum a fornitori

Descriptio

Commutator RNV-A1-12D-1250A est dispositivum controlis et protectionis altae capacitatis, specialiter pro systematibus distributionis mediae tensionis 12kV. Huic commutatori sunt adiuncta facilia installationis, exigua maintenance, longa vita, parva magnitudo, pretium modicum, securitas et fides. Circuitus principalis 1250-20kA (4s), 25KA (3s), vita mechanica 10000 vice. Haec series productorum mittetur postquam transierit inspectionem plenam et conformabitur requisitionibus pertinentibus GB1984-89 et GB/T1984-2014 de circuitobus ruptoribus altae tensionis AC.

Parametri Producti

Numerus Seriae Item Unitas Parameter
1 Frequensia Nominata Hz 50
2 Currentus Nominatus A 1250
3 Currentus Sustentandus Breviter Nominatus kA 20/25
4 Currentus Sustentandus Cuspide Nominatus kA 50
5 Duratio Nominata Circuitus Brevis s 4
6 Currentus Faciendi Circuitus Brevis Nominatus kA 50
7 Serie Operativa Nominata - 0-0.3s-180s-co

Dimensiones installationis

FAQ
Q: Quae sunt principia praestantiae?
A:

Virtutes cardinales in quattuor dimensiones concentrentur: capacitas alta portandi currentem, fidelitas isolationis, adaptabilitas structurae, et operatio atque conservatio intelligentia: ① Design ad altam portationem currentis: Currentis nominata usque ad 1250A, brevis tempus tolerans currentem ≥31.5kA/3s, satisfacit necessitatibus scenariorum distributionis potestatis sub alto onere; ② Fidelis isolatio et extinguentia arcus: Fortitudo isolationis gas SF6 est 2-3 vices maior quam aer, cum celeritate extingendi arcum velox et ruptura arcus nulla, apta pro ambientibus asperis sicut humiditas, pulvis et spuma salis; ③ Adaptatio exclusiva pro armariis inflabilibus: Volumen tantum 1/3 traditorum interruptorum circuiti aperti, et magnitudo installationis accurate congruit compartimento commutatorio armarii inflabilis sine additione structurae armarii; ④ Facilis operatio intelligentia: Sustentat controllem remotam electricam (protocollo RS485/Modbus) et operationem manualem emergentiam, instructa functionibus monitorandi pressionem gas SF6 et feedback status positionis, apta pro necessitatibus stationum sine custode; ⑤ Parva expensae operationis atque conservationis: Design camerae gaseae sigillatae, ratio effugiendi gas ≤0.1%/annum, vita mechanica totius machinae ≥10000 vices, multum minuit frequentiam posteriore conservationis.

Q: Quid est RNV-A1-12D-1250A SF6 alta tensio gas insulata inflabilis armari circuitus interruptor?
A:

Est specialis circuiti interruptor cum insulante gaseo, cuius tensio nominata est 12kV et amperage nominatus 1250A, pro armariorum compactorum inflandorum designatus, utens SF6 gas tamquam medium insulantem et arcum extinguentem. Hoc exemplar tria munera core integra: interruptionem circuiti in casu defectus brevis circuitus, rumpere currentem oneris, et isolationem circuiti. Praebet structuram compactam, excellentem praestantiam sigillantis et fortiter tolerat condiciones ambientales, aptum pro scenariis distributionis medii voltus 12kV sicut unitates main ring, armaria ramalia et stationes commutatoriae, et est componentis switch protectionis core ad distributionem urbis electricitatis et supply power industriarum parcorum.

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum