Capacitas-Maxima Celeriter-Commutator/Fluxus-Maximus Limitor Interruptor

  • Large-Capacity High-Speed Switch/High-Current Current-Limiting Circuit Breaker
  • Large-Capacity High-Speed Switch/High-Current Current-Limiting Circuit Breaker

Attributa principalia

Marca RW Energy
Numerus Modeli Capacitas-Maxima Celeriter-Commutator/Fluxus-Maximus Limitor Interruptor
Votum nominatum 12kV
currus electricus nominatus 2000A
Frequenta nominata 50/60Hz
Series DGXK

Descriptiones productorum a fornitori

Descriptio

Introductio Producti

DGXK1 Magnae Capacitatis Celeris Commutator est productum in armario collocatum DDXK1 Magnae Currentis Circuito Limiter (etiam cognitum ut Limitator Circuitus Transitorii, Limitator Currentis, vel FCL). Armariolus est designatus et manufacturatus secundum species commutationis altae tensionis sicut KYN28, KYN18, GG 1A, et XGN, cum latitudine 1000-1500mm et profunditate 1300-2000mm; designa non standard quoque possunt praeberi secundum necessitates usuariorum.

Characteres Principales

  • Celeris Interruptio: Operatur et interrumpit currentem transitorium in parte frontali primae semiondae frequentiae potentiæ transitorii, multo antequam currentus transitorius ad suum apicem ascendat. Tempus totale interruptivum est 2-5 ms, circa decies vel vicies celerius quam circuitobrakes.

  • Limitatio Currentis Interruptiva: Incipit limitare currentem transitorium 1ms post occurrentiam circuitus transitorii, et denique limitat currentem transitorium ad 15%-45% valoris expectati.

  • Magna Capacitas Interruptiva: Rated prospective short-circuit breaking current est 63-200kA, dum rated short-circuit breaking current circuitobrakorum communium solito tantum 40.5-50kA attingere potest.

  • Sensor Rogowski Internus: Praebet mensuram accuratam, celerem responsivitatem, et posse disponi in phasibus separatis vel in armario.

  • Magna Fiducia: Unum ex competitivis huius producti est sua superior fiducia. Designa specialia et artifex operis fiduciam altam producti assecurant, quod in campo probatum et bene acceptum est.

  • Flexibilis Dispositio Armarioli: Commutatorium dispositum esse potest modo combinato vel independente. Interne, uno vel duobus setis disjunctorum instrui potest secundum necessitates instituti designandi, vel serie cum switchis vacuis connecti. Habet quinque-preventionem interlocking, operationem flexibilem, et commodam pro mutatione partium reservarum.

Parametri Principales

No.

Item

Unitas

Parametri Technici

1

Rated Current

A

630~6300

2

Rated Voltage

kV

7.2/12/20/40.5

3

Rated Frequency

Hz

50/60

4

Rated Prospective Short-Circuit Breaking Current

kA

63/80/120

5

Rated Insulation Level (Power Frequency / Lightning)

7.2kV

kV

23/60 kV

12kV

kV

42/75 kV

20kV

kV

50/125 kV

40.5kV

kV

95/185 kV

6

Breaking Time

ms

2~5ms

7

Cut-off Current / Prospective Short-Circuit Current Peak Value

%

20~45

8

DC Resistance of Main Circuit

μΩ

<40

9

Operating Current Setting Range

kA

6kA~60kA

10

Rated Breaking Current of Fuse

kA

63/120

11

Rated Short-Time Withstand Current of Main Circuit

kA/s

31.5/2

12

Rated Peak Withstand Current of Main Circuit

kA

80

FAQ pro
Q: Quomodo certa fieri possit accuratio detectionis currentis
A:

Aestimatus Rogowskii Coil currenti sensori interno instructus, habet celerem responsionem et bonam linearitatem. IEE-Business supportat separationem phase vel integrationem in armarios ad fiduciam detectionis assecurandam.

Q: Numquid cum interruptore circuitus vacuo in serie uti potest?
A:

Bene. Comutatores vacui, comutatores disiunctores, vel dispositiva combinata intra armarium flexibiliter configurari possunt, quod permittit operationem normalem a commutatore vacuo perfici et defectus circuitus clausi celeriter a DGXK limitari.

Q: Quae est differentia celeritatis inter DGXK et communes disjunctores?
A:

Tempus totum rumpendi solummodo 2-5ms est, quod decem bis vel viginti celerius est quam disjunctores traditionales, et potest completare amputatio currentis limitante in margine ascendente primae semisinae currentis circuitus clausi.

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 30000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 100000000
Locus Operis: 30000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 100000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: robot/Energia nova/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

  • Systemata automationis distributionis solutio
    Quae sunt difficultates in operatione et maintenance lineae aereae?Difficultas una:Lineae distributionis aerea latam extensionem habent, terrain complicatam, multas ramificationes radiantis et supply power distributum, quod "multa culpa lineae et difficultas in reperiendo errore" producit.Difficultas duo:Reperire manu errorem tempus consumit et laboriosum est. Simul, currentem, tensionem et statum commutationis lineae non potest comprehendere in tempore reali, propter defectum mediorum technicor
    04/22/2025
  • Solutio Integratum Monitorationis Intelligentis Potentiae et Administrationis Efficienciae Energeticae
    Visio generalisHoc opus ad praebendum systema intelligentis monitorii electricitatis (Systema Managementis Electricitatis, PMS) centrum ponit in optimisatione termino ad terminum ressource electricitatis. Per constitutionem framework managementi clausi "monitoring-analysis-decision-execution," iuvat societates a simpliciter "electricitatem utendo" ad intelligenter "electricitatem administrando" transire, tandem ad fines usus energiae securi, efficientis, paucicarbonis et oeconomici perveniens.Po
    09/28/2025
  • Una Nova Solutio Modularis pro Systematibus Generationis Energiae Photovoltaicae et Storaginis
    1. Introductio et Background Investigativus1.1 Status Quodammodo Solaris IndustriaeUt una ex copiosissimis fontibus renovabilium, solis energiae developmentum et usus iam centrum factus est globali transitioni energeticae. Recentibus annis, impulsu politarum mundi, industria photovoltaica (PV) prodigiosa progressione gavisa est. Statistica indicant quod PV industria Sinica vidiit incrementum 168-plex durante "Duodecimo Quinquennio". Ad finem 2015, installata PV capacitas excessit 40,000 MW, tres
    09/28/2025
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum