• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Inverter Booster Integrated Substation combinet inversionem/boosting

  • Inverter Booster Integrated Substation combines inversion/boosting
  • Inverter Booster Integrated Substation combines inversion/boosting
  • Inverter Booster Integrated Substation combines inversion/boosting

Attributa principalia

Marca Wone Store
Numerus Modeli Inverter Booster Integrated Substation combinet inversionem/boosting
Votum nominatum 40.5kV
Series IBSUB

Descriptiones productorum a fornitori

Descriptio

Product Description

Substatio Inversoris et Amplificatoris Integrati, vulgo Substatio Inversoris et Amplificatoris, est infrastructura electrica specialis, quae functiones inversoris potentiae, transformatoris amplificatoris et substationis in unum unitatem integratam combinat.

Substatio Inversoris et Amplificatoris Integrati pertinet ad campum substationum, ad solvendum defectus magni voluminis constructionis et perditionis potentiae, qui a duobus apparatis necessariis pro conversione directa in alternantem et amplificatione alternantis in systemate generationis photovoltaicae oriuntur.

Substatio Inversoris et Amplificatoris Integrata continet partem bassam tensionis, partem altam tensionis et partem variabilis tensionis, quarum characteristica est dispositio partis bassae et altae ante et post, cum parte variabili sita ad dextram vel sinistram partis bassae et altae.

In parte bassa, currentes directi a systemate generationis photovoltaicae colliguntur et convertuntur in currentes alternantes; in parte transformationis, currentes alternantes bassi in currentes alternantes altos transformantur.

 In parte alta, potentia alterna alta protegitur et mensuratur. Substatio Inversoris et Amplificatoris Integrata utilizatur ad conversionem et amplificationem potentiae generatae a modulis photovoltaicis in potentiam stabiliter utilisabilem.

Characteristica Producti 

  • Designo Integratum Universale: Integritas functionum inversoris, transformatoris amplificatoris et substationis in unam unitatem, eliminans necessitatem configurationis separatae multorum apparatorum, simplificans dispositionem systematis et reducens costus acquisitionis apparatorum.

  • Solutio Dolorum Systematis PV: Reducit significative onus constructionis in loco (exempli gratia, collocationem conductorum, installationem multorum apparatorum) et minimat perditionem potentiae in conversione DC-AC et amplificatione AC, meliorans efficaciam globalis utilisationis energiae systematis PV.

  • Structura Dispositionis Scientifica: Partes bassa et alta disponuntur secundum ordinem (ante et post), cum pars variationis tensionis sita sit ad dextram vel sinistram partium duarum. Haec dispositio clara est, facile conservanda, et optimat utilisationem spatii interni.

  • Coverage Functionum Totius Processus: Comprehendit totum catenam elaborationis energiae PV--a collectione potentiae directae, conversione DC-AC, amplificatione de bassa ad altam tensionem, usque ad protectionem et mensurationem altam--nulla alia apparatus supportivus requiritur.

  • Adaptabilitas Fortis Extra: Ut substatio transformatoris extra, designatur cum resistentia adversus meteora (exempli gratia, impermeabilitas, pulvisimpermeabilitas) et adaptabilitate ambientali, apta ad operandum in ambiente extra maioris partis stationum PV.

  • Magnitudo Compacta & Spatium Salvum: Adoptat structuram compactam (consistens cum definitione "transformatoris substationis compacts"), quae occupat minus terrae et est praesertim apta pro projectis PV cum spatio limitato (exempli gratia, PV tecti).

  • Concordia Alta cum Scenariis PV: Customizatur pro characteristicis potentiae directae generatae a PV, securans altam efficientiam inversionis et stabilem performance amplificationis, evitans incompatibilitates cum apparatorum electricorum generalibus.


Parametri Technologici

Nomen Parametri

Unitas

Data Specifica

Tensio Nominalis

kV

12, 24, 40.5

Frequensia Nominalis

Hz

50/60

Currentus Nominalis Interruptoris Altae Tensionis

A

630, 1250

Currentus Nominalis Apparatorum Altae Tensionis

A

630, 1250

Currentus Sustentandus Nominalis Altae Tensionis (4S)

kA

20, 25, 31.5

Currentus Sustentandus Nominalis Apex Altae Tensionis

kA

50, 63, 80

Currentus Interrumpendi Nominalis Altae Tensionis

kA

20, 25, 31.5

Tensio Sustentanda Nominalis Frequentiae Potentiae (1MIN)

kV

35, 50, 70

Tensio Sustentanda Fulminis (Apex)

kV

75, 125, 170

Protectio Ingressus

/

Clavis IP54

 

Scenarii Applicationis

  1. Stationes PV Terrestres Magnae: Quasi apparatus centrale elaborationis energiae, centraliter tractat potentiam directam ex arrayis PV areae magnae. Post conversionem et amplificationem, potentia connectitur ad rete potentiae nationali/regionali, supportans generationem PV magnae scalae et supplymentum rete.

  2. Projecta PV Distributa (Industriales & Commercials): Aptum pro systematibus PV tecti factorum, mallorum, et aedificiorum officinarum. Suus designus compactus salvat spatium tecti, et functio integrata minuit difficultatem installationis in loco, satisfaciens necessitatibus "generationis localis et consumtionis localis" pro corporibus.

  3. Stationes PV Alleviationis Paupertatis Extra: Adaptatur ad ambientes externos asperos regionum ruralium remotarum (exempli gratia, plateaux, montes). Potest celeriter realisare conversionem stabilam potentiae PV cum opere constructionis minimo, providens electricitatem fidelem pro regionibus pauperibus et supportans constructionem energiae ruralis.

  4. Systemata Hybrida PV-Storage: Cooperat cum apparatis storage. Post conversionem et amplificationem potentiae PV ab hoc productu, pars potentiae directe supplentur ad onus, et pars excessiva stantur in systemate storage (vel connectuntur ad rete post amplificationem). Hoc meliorat rationem utilisationis energiae PV et solvit problemam output instabilis potentiae PV.

FAQ
Q: Quam diu ducit ut praefabricata nova substationis energiae in loco installetur
A:

Installatio in situ tantum 1–3 dies pro plerisque modellis postulat. Contra substationes traditionales, omnes componentes (transformatores, armarii HV/LV, commutationes) praefabricati et praeexaminati in fabrica sunt. Operis in situ limitatur ad: 1) collocandum unitatem super terrain planam et induritam (fundamenta concreta complexa non requiruntur); 2) connectendum lineas venientes basso voltu et lineas exeuntes alto voltu.

Q: Num potest praefabricata nova energia substationes operari cum systematibus solaris et venti?
A:

Ita. Plurimi praefabricati novae energiae substationes (sicut: praefabricati cubiculi, castrum-forma unitates) permittunt integrationem cum systematibus solari et ventoso. Illae convertere possunt bassam tensionem AC ab inverteribus PV vel turbineis venti ad 10kV/35kV (standard tensiones rete) pro iunctura sine solutione. In scenariis specialibus, formae speciales venti addunt resistentiam venti (≤35m/s), dum solares optimizant dissipationem caloris pro generatione media die sub alto onere.

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: transformator/pars componentium/cable et filum/Energia nova/Instrumenta inspectionis/apparatus electrum altum voltus/Aedificii electritas Apparatus electricus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/aestus apparatus/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

  • Integrata Solutio Potentiae Mixtae Ventus-Solaris pro Insulis Remote
    AbstractusHoc propositum praebet solutionem integratam energetica innovativam, quae profunde combinet generationem venti, photovoltaicam, accumulationem hydroelectricam et desalinizationem marina. Id intendit systematica adflictiones corde insularum remotarum solvere, inter quas difficultates coperturae rete, costus alti generationis diesel, limitationes accumulationis battery traditionalis et raritas fontium aquarum dulcium. Haec solutio synergiarum et autonomiae in "supply power - energy stora
    10/17/2025
  • Systema Hybridum Ventus-Solar cum Controllo Fuzzy-PID pro BATTERIAE GESTIONE ENHANCED et MPPT
    AbstractusHoc propositum systema generationis electricitatis mixtum venti-solaris praebet, quod superiore technologia controlis innititur, ad efficaciter et oeconomico satisfaciendum indigentiis electricitatis regionibus remotis et scenariis applicationis specialibus. Nucleus huius systematis in systemate intelligenti controlis centrat, quod circa microprocessorem ATmega16 constat. Hoc systema Maximum Power Point Tracking (MPPT) tam venti quam solaris perficit et algorithmo optimato, qui combini
    10/17/2025
  • Solutio Mixta Venti-Solis Costo-Effectivus: Convertor Buck-Boost et Caricatio Intelligens Reducunt Costum Systematis
    AbstractHoc solutio novum systema generationis potestatis venti-solaris altae efficientiae proponit. Ad corrigendum defectus in technologiis existentibus, sicut usus parvus energiae, brevis vita bateriarum, et infirma stabilitas systematis, hoc systema convertes DC/DC buck-boost digitaliter plene controlatos, technologiam parallelam interlaced, et algorithmum intelligentem tristagium caricationis adhibet. Hoc permittit Maximum Power Point Tracking (MPPT) in latiore ambitu velocitatum venti et ir
    10/17/2025
Instrumenta Libera Cognata
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum