H61 30 kV 33kV 34.5kV 35 kV 46 kV 630kVA IEE-Business Alta Tensio Immersa in Oleo Distributiva Transformator

  • H61 30 kV 33kV 34.5kV 35 kV 46 kV 630kVA High Voltage Oil Immersed Distribution Transformer
  • H61 30 kV 33kV 34.5kV 35 kV 46 kV 630kVA High Voltage Oil Immersed Distribution Transformer
  • H61 30 kV 33kV 34.5kV 35 kV 46 kV 630kVA High Voltage Oil Immersed Distribution Transformer
  • H61 30 kV 33kV 34.5kV 35 kV 46 kV 630kVA High Voltage Oil Immersed Distribution Transformer
  • H61 30 kV 33kV 34.5kV 35 kV 46 kV 630kVA High Voltage Oil Immersed Distribution Transformer

Attributa principalia

Marca Rockwell
Numerus Modeli H61 30 kV 33kV 34.5kV 35 kV 46 kV 630kVA IEE-Business Alta Tensio Immersa in Oleo Distributiva Transformator
Votum nominatum 33kV
Frequenta nominata 50/60Hz
Capacitas nominata 630kVA
Series S

Descriptiones productorum a fornitori

Descriptio

Product Description

33/0.4kV Pole mounted High Voltage  Oil Immersed Toroidal Power Transformer

Transformator olei immersus alta tensio 33/0.4kV 630kVA, constructus ex materia H61, praebet exacta specifica 33kV alta tensio ad introductum et 0.4kV bassa tensio ad exitum. Id aptum est pro scenariis medii et magni oneris, servit ut apparatus core pro distributione electricitatis industriali et civili.

Adoptans oleum insulans speciale et devoluta H insulata, transformator habet resistens insulans ultra 1000MΩ. Systema refrigerationis naturalis circulationis olei immersi certificat ut temperatura permaneat stabilis infra 85℃ sub plena onere, faciens id adaptabile ad complexos ambientes externos. Equipatus cum alarma protectiva superpressurae et supertemperaturae, habet capacitem sustinendi interruptus circuitus 25kA/2s. Gradus protectionis IP54 coniunctus cum habitaculo resistentia corrosioni efficaciter resistit erosionibus imbris et pulveris.

Largissime usus in parvis industrialibus, complexibus commercialibus et projectis transformationis reticulorum distributionis, transformator transiit certificationem IEC 60076 et testes typi auctoritativi. Decennium garantiae controlis qualitatis garantit vitam designata 20 annorum, supportat customizationem OEM et praebet solutionem cost-effective pro distributione electricitatis stabili.

Distribution Transformer
1-Tres phase olei immersae
2-Specializatio in transformatoribus decem annos
3-Relationes Testuum Typi Auctoritativorum
4-Offerta Servitii OEM

(I). Product Specification:

Frequency: 50Hz or 60Hz
Capacity: 5kVA ~630kVA
Primary Voltage: 2400~46, 000V
Secondary Voltage: 120~ 600V

Quaedam horum transformatorum terrae tegent voltage levels includentes: 3.3 kV 5.5 kV 6 kV 6.6 kV 7.2 kV 10kV 10.5kV 11kV 13.2 kV 13.8 kV 15kV 17.5 kV 20 kV 22kV 24kV 30 kV 33kV 34.5kV 35 kV 46 kV etc. et customizatio disponibilis est.

Numerus Modeli

S9

Nucleus

Transformator Nucleiformis

Modus Refrigerae

Transformator Immersus Oleo

Typus Involutionis

Transformator Bifiliaris

Certificatio

ISO9001-2000, ISO9001, CCC

Usus

Transformator Potentiae

Characteres Frequentiae

Frequens Potentiae

Figura Nuclei

Anulus

Signum

Rockwell

Color

Canus, Viridis aut Customizatus

Paccula Transportis

Crates Lignea

Specificatio

IEC/ANSI/IEEE

Signum Mercuriale

Rockwell

Origio

Sinensis

Codex HS

8504330000

Capacitas Productiva

20000

Scopulus Producti:

  • Conformatur vel superat Normas ANSI

  • Firma constructio cum excellentibus capacitatibus sustinendi circuitum curtem et thermicam

  • Transformatores ROCKWELL sunt efficientiores per reductionem perditorum in carico vacuo et in carico

  • Customizati ad Specifica Requirimenta

Caracteristica Transformatoris Distributionis Triphasici Typi in Polum Fixati:

  •  Transformator triphasicus cum costu plus economico

  •  Typus in polum fixatus pro installatione facili

  •  Typus impletus oleo pro methodo refrigerationis

  •  Transformator triphasicus in polum fixatus utitur pro transmissione et distributione potentiae, cum perditis minimis et efficacitate alta

  • Hic typus transformatoris triphasici in polum fixati est designatus ad augmentandum robur contra circuitum curtum et thermicum

  • Terminatio durabilis et resistens ad corrosionem conformat omnibus Normis ANSI/IEC/BS pro transformatore monophasico in polum fixato.

  • Systema Designii Automati Typi in Polum Fixati TRIAS ROCKWELL securitatis unicorum requirimentorum clientis.

  • Lamina Siliconica C. R. G. O. vel Metallicum Amorphum disponibilis est pro optione clientis.

Series D16 OA Transformator Triphasicus in Polum Fixatus (Nucleus CRGO BIL 150)

Imago Producti

Transformator Potentiae Toroidalis Imbutus Oleo in Polum Fixatus Tensionis Altae

11kV 33kV 35kV 44kV Transformator Potentiae Toroidalis Imbutus Oleo in Polum Fixatus Tensionis Altae

Transformator Potentiae Toroidalis Imbutus Oleo in Polum Fixatus Tensionis Altae

Transformator Distributivus Imbutus Oleo H59 H61

Societas Wenzhou Rockwell Transformer Co., Ltd., quae specializatur in producendo, disvelopando et mercando producta transmissoris et distributoris potentiae. Societas constituta est anno 2008, filia societatis ROCKWILL GROUP, quae locata est in civitate Wenzhou, provincia Zhejiang, China.

Nostra principalia producta includunt commutatores, unitates main ring, transformatores, commutatores rumpentes onus, circuitus interruptores SF6/vacuum, substationes, auto-reclosers, regulatores tensionis, sectionalizatores automaticos, tap-changers, CT et PT etc.

Multorum harum rerum habentur relationes certificationis auctoritativarum internationalium KEMA Netherlands et CESI Italy.

Habemus team technicam professionalem, quae potest tibi praebere solutio designii plenum et supportum technicum.

Officina

Transformator Distributivus Imbutus Oleo H59 H61

Testimonia

Transformator Distributivus Imbutus Oleo H59 H61

 

Team

 

Transformator Distributivus Imbutus Oleo H59 H61

Projectus

Fabricator Transformatoris Distributivi Imbuti Oleo H59 H61 13.2kV 13.8kV 15kV 33kV

 

Navigatio

Fabricator Transformatoris Distributivi Imbuti Oleo H59 H61 13.2kV 13.8kV 15kV 33kV

Attentio

  1. Termen paymenti: Accipimus TT, 30% depositum et 70% restitutio contra copiam BL.

  2. Tempus delivery: Saepe sumit circa 15-20 dies.

  3. Standard package: Usualiter utimur casu robusto de abietina pro protectione.

  4. Logo: Si habes bonam quantitatem, absolutum non est problema facere OEM.

  5. Noster mercatus: Nostri producta sunt populares in Indonesia, Philippines, Russia, USA, Medio Oriente et alii. Quaedam sunt nostri clientes regulares et alii sunt in developmento. Speramus te iungi nobiscum et facere mutuum beneficium ex nostra cooperatione.

  6. Garantia: in 12 mensibus post datam BL.

Noster Servitium

    1. celer responsus in tempore praevenditionis iuvat te ut ordinem accipias.

    2. eximia servitia in tempore productionis faciunt te scire singulos passus a nobis factos.

    3. fides qualitatis solvit tuas postvenditionis dolores capitis.

    4. longa qualitatis garantia tibi certificat ut emas sine dubitatione.

    Cur ROCKWELL Eligeas

    • Unica auctoritas globaliter.

    • Plus quam decem annorum experientiae professionalis in industria apparatorum electricorum.

    • Offertur technica subsidium online professionale pro perfectione tuae solutionis electricae gratis.

    • Experientia venditionis et consilium.

    • Omnia producta cum accessoriis sub severo controllo qualitatis et ultima inspectione ante expeditionem.

    • Possumus asserere potens pretium competitivum et producta fidei digna qualitate.

    • Maxime competitivus portus ex nostro proprio expeditore.

    • Garantia: duodecim menses

    • Sive magnus sive parvus ordo, possumus tibi servitium unum ad unum praebere.

FAQ
Q: Quomodo H61 transformatores selecantur
A:

1. Quomodo Capacitatem Transformatoris Distributionis H61 Selectam Facere

  • Secundum conditiones actuales et tendentias developmentales selectio facienda est: Si capacitas nimia est, "equus magnus currum parvum trahens" phenomenon oritur, quod ad utilitatis ratum parvum et incrementa perditorum in vacuo ducit. Si capacitas minor est, operatio supra onus fit, quae perditas augeat et, in casibus severis, ad supercaldum vel incendium ducere potest.
  • Recommodatio: Capacitas rationabiliter secundum requisitiones oneris normalis et culminantis loci installationis eligenda est.

2. Quomodo Typum Modeli Transformatoris Distributionis H61 Selectam Facere

  • Recommodatur ut transformatores novi, efficientiores et energiam servantes adhibeantur qui materiales, technologias et processus fabricationis praestantes adhibent ad consumtionem energiae reprimendam.
    • Transformatores ex alliage amorpho: Perditorum in vacuo diminuunt circa 80% et currentis in vacuo circa 85% comparata cum transformatoribus coris ferro-silicis traditonalibus. Specialiter apti sunt pro retibus electricis ruralibus vel regionibus cum factoribus oneris minimis.
    • Exemplum: Unus transformator oleosus trinis phasis quinque membris ex alliage amorpho (200 kVA) habet perditam in vacuo 0.12 kW et perditam sub onere 2.6 kW; dum transformator S9 eiusdem capacitatis habet perditam in vacuo 0.48 kW cum identica perditam sub onere. Hoc annuis servationibus energiae 3,153.6 kW·h per unum transformator ducit.
    • Transformatores distributionis totaliter clausi cum coris involutis: Nova generatio transformatorum parvo sonorum et perditorum minutorum cum designo corei sine sutura, quae adhibet materialis utilitatem, perditorum in vacuo reprimendo 7-10% et currentis in vacuo 50-70%.
    • Transformatores automati capacitate adiustabiles sub onere: Characteristicae sunt connectiones windings serie-parallel cum controlleribus automaticis, qui modos operationis adhibent secundum data oneris reali temporis. Specialiter apti sunt pro applicationibus cum oneribus dispersis, variationibus saecularibus fortibus et factoribus oneris mediis minimis.

3. Quomodo Locum Installationis Transformatoris Distributionis H61 Selectam Facere

  • Proxime ad centrum oneris instala ad radii supply minimizandum—ideale intra 500 metrorum. Etiam in regionibus cum oneribus dispersis, plures deberent intra hanc rangem permanere.
  • Dispositionem optima adhibe, simul conditionibus loci et requisitionibus ambientalibus satisfaciens, ad efficientiam augendam et perditas lineares reprimendas.
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 60000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 100000000
Locus Operis: 60000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 100000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

Instrumenta Libera Cognata
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file