• DS22B 126kV 145kV 252kV 363kV 420kV 550kV High voltage disconnect switch
  • DS22B 126kV 145kV 252kV 363kV 420kV 550kV High voltage disconnect switch
DS22B 126kV 145kV 252kV 363kV 420kV 550kV High voltage disconnect switch
discuss personally
Model
DS22B-550D/5000-63
DS22B-550D/4000-63
DS22B-420D/3150-63
DS22B-363D/5000-63
DS22B-363D/4000-63
DS22B-252D/5000-63
DS22B-252D/4000-63
DS22B-252D/3150-50
DS22B-252D/2000-50
DS22B-145D/2500-50
DS22B-126D/4000-50
DS22B-126D/3150-50
DS22B-126D/2000-50
Basic info
Brand ROCKWILL
Model NO. DS22B 126kV 145kV 252kV 363kV 420kV 550kV High voltage disconnect switch
Rated voltage 550kV
Rated normal current 5000A
Rated frequency 50/60Hz
Rated peak value withstand current 160kA
Rated short-time withstand current 63kA
Series DS22B
Product Detail

Product introduction

DS22B Switch Disconnector is a kind of outdoor HV electricity transmission equipment at three-phase AC frequency of 50Hz/60Hz. it is used for breaking or connecting HV lines under no loads so that these lines can be changed and connected and the way he electricity runs is changed, in addition, it can be used to exercise safe electrical insulation for such HV electric apparatuses as bus and breaker. The switch can open and close inductance/capacitance current and is able to open and close the bus to switch current.

This product is in the single-post single arm vertical telescopic structure. The contact is of the forceps-type, Vertical insulating breaks will be formed after the opening. The product can be used as an disconnect switch for bus. it is directly installed directly under the bus and only occupies a small space. JW10 earthing switch can be attached for grounding the bus at the lower layer, The grounding for the bus at the upper layer requires an independent earthing switch. 363kV and 550kV switch Disconnector and earthing switch are equipped with the SRCJ2 motor actuator for the single pole operation, Meanwhile, the tre-pole linkage can be achieved, The 126kV and 252kV isolating switches adopt SRCJ7 and SRCJ3 motor-based actuators to realize the tri-pole linkage. The grounding switch adopts CS11 and SRCS manual actuators to actualize tri-pole linkage.

This switch Disconnector has passed the verification by the review procedure organized by China Machinery industry federation that the product structure and performance satisfy the requirements on perfection, and product's performance indices have reached the internal level of the same kinds of products.

DS22B switch Disconnector comprises three single poles and actuator, Each single pole is made of a base, post insulator operating insulator and conductive part. The conductive part includes the gear box and foldable conductive arm fixed on the top of the post insulator, and the fixed contact hanging on the overload bus.

The actuator drives the operating insulator, and through the ink lever-driven conducive arm, if and lower the insulator to tighten or separate the moving contact and fixed contact on the directly overhead bus line to open or close the disconnect switch. After the opening, a vertical insulating break will be formed.

Main characteristic

  • State-of-art structure: The switch Disconnector is in the single-arm, foldable and telescopic structure, The driving elements and balancing springs are sealed within the conductive tube to reduce their adverse effects on natural environment and render the appearance compact and simple; The drive base adopts a link lever, Compared with angular wheels, the product is simpler and easier to adjust.
  • Superior conductance system: The conductive part made of Al-alloy of high conductance rate is characteristic of good conductance, high mechanical strength, light weight and strong corrosion resistance; The current will pass through the foldable area of the conductive arm via soft connection (without recourse to any movable contacts) to ensure reliable conductance, few maintenance, no examination, and long-term reliable operation.
  • Stable static contact structure:The hanging fixed contact is fixed with a pure alloy conductor ring to realize high degree of current flow capacity, The fixed contacts are hanged and fixed with the steel wires in the triangle shape to ensure the adjustment friendliness, stability and the reduction in vertical displacement.
  • Provide one-key sequential control "double confirmation" function expansion.
  • Unique forceps-type contact: The contact is of the forceps-type. The moving knife switch will be additionally accompanied by the extremal spring to ensure the constant contact pressure. The lower end of the knife switch is in sot connection with the base (without recourse to any movable contacts) to ensure reliable conductance and avoid the over-heating from poor contact The base for the moving contact is welded with the upper guide tube to prevent the water from penetrant into the milling mouth of the clamping head, The connection between the base of the contact and the draw rod is uniquely sealed to ensure no water penetration or accumulation at the base for the movable contact, In this way, the rust of parts within the conducive arm or the obstacles to the movement of the contact as a result of the ice coating in winter will be eliminated, and the failure of the disconnect switch to be opened or closed will also be avoided; The arc contact can be mounted onto the movable and fixed contacts to enable the switch Disconnector to switch current capacitive and inductive current by opening and closing bus line.
  • Simple and superior earthing switch: 363kV and above earthing switch is in the single-arm standing and openable structure, with the structurally simple plug-type contact. The conductive rod for grounding will move in two steps at the moments of opening and closing. At the moment of closing, the conductive rod will rotate vertically and rise up lo the fixed contact, and then automatically plug itself into the star-shaped contact. By doing so, the contact will be made reliable and be able to sustain the heavy short-circuit current.

Main technical parameters

Order notice 

Product model, rated voltage, rated current, rated short-time withstand current and creepage distance must be specified at the goods-ordering time;

It can be decided whether a earthing switch should be attached to the switch Disconnector;

It must be decided whether the upper bus line of the switch Disconnector is soft or hard. Additionally, the external diameter of the tubular busbar shall be specified;

It must be decided whether the disconnect switch is arranged in cross-over or parallel form;

The actuator's model, motor's voltage, control voltage and the number of contacts for auxiliary switch.

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Research and Application of Communication Security Strategies for Smart Meters
Research and Application of Communication Security Strategies for Smart Meters
1. Security Threats Facing Smart Meter Communications1.1 Physical Layer Security ThreatsPhysical layer security threats refer to factors that damage or interfere with the hardware devices and physical connections of smart meters, directly affecting their normal operation and data transmission. From the perspective of equipment damage, harsh natural environments such as lightning strikes, floods, and earthquakes can directly destroy the hardware circuits and structures of smart meters, rendering
Echo
09/01/2025
Analysis of Issues and Causes in Smart Meter Testing
Analysis of Issues and Causes in Smart Meter Testing
1. Issues and Cause Analysis in Smart Electricity Meter TestingDuring the verification of smart electricity meters, inspections must be conducted on the meter’s appearance, as well as the clarity and integrity of nameplate markings. Additionally, careful checks are required for physical damage and whether the display can show digits completely. A power-on inspection is also necessary. If error codes appear on the display after power-up, faults should be identified and addressed according to the
Oliver Watts
09/01/2025
Analysis of Common Operational Fault Causes in Smart Electricity Meters
Analysis of Common Operational Fault Causes in Smart Electricity Meters
With the continuous development of smart grids, smart electricity meters are being increasingly widely applied, and various types of operational faults in smart meters are frequently encountered in energy measurement work. This paper analyzes the causes of smart meter failures and proposes corresponding solutions, using several actual operational fault cases as examples.1. Black ScreenA black screen refers to a powered meter with no display, which is the most commonly occurring fault in field-op
Felix Spark
09/01/2025
What tests are required for a qualified smart electricity meter?
What tests are required for a qualified smart electricity meter?
In today's world, not wearing a watch is no longer unusual, but not having an electricity meter is a serious issue. As a measuring instrument vital to people's daily lives, the electricity meter is an essential tool for power consumption measurement and billing in every household. According to current national strategic requirements for smart grid development, smart electricity meters have been widely applied and promoted, bringing entirely new and extensive market opportunities to the metering
Oliver Watts
09/01/2025
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
1 Analysis of Smart Meter Faults and Their Impact on the Power Grid1.1 Introduction to Smart Meter Functions and Their Critical Role in Modern Power GridsSmart meters exchange data in real time with power companies through two-way communication, enabling functions such as remote meter reading and dynamic tariff adjustment. This capability allows users to adjust their consumption based on real-time pricing, achieving energy savings and cost reduction. Meanwhile, smart meters support grid automati
Felix Spark
09/01/2025
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Meter reading, verification, and billing are critical operations for power companies, and their efficiency directly impacts the company's sustainable development. In recent years, with the widespread adoption of intelligent technologies, smart meters have been promoted and applied in power companies, driving transformation in meter reading and billing operations. The integrated application of smart meters and meter reading, verification, and billing information systems has become a key developme
Echo
09/01/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!