DNH50-50 Disiectrum DC Isolatum PV System Disiectio Concentrata Inversoris Protectio

  • DNH50-50 DC Isolate Switch PV System Disconnection Concentrated Inverter Protection
  • DNH50-50 DC Isolate Switch PV System Disconnection Concentrated Inverter Protection
  • DNH50-50 DC Isolate Switch PV System Disconnection Concentrated Inverter Protection

Attributa principalia

Marca Switchgear parts
Numerus Modeli DNH50-50 Disiectrum DC Isolatum PV System Disiectio Concentrata Inversoris Protectio
currus electricus nominatus 50A
extremum 4p
Series DNH50

Descriptiones productorum a fornitori

Descriptio

Series DNH50-50 DC Isolate Switch specialiter pro disiunctionem circuitus directi in systematibus PV et storage energiae constructus est. Contra communes commutatores disiunctores DC, hic mecanismum sine arcu patentatum habet, quod pericula ex arcu manuale operatione eliminat. Hoc non solum securitatem augebit, sed etiam vitam componentium internorum prolongabit.

Sive in inversores solares, packes batteriarum, vel combiner boxes string integrari volueris, DNH50-50 DC Isolate Switch fiduciam disiunctionis praebet pro maintenance regulari, emergency power-off, vel handling fault.

DC Isolate Switch Key Features

Arc-Free Operation: Nulla arcus in commutatione, securitatem operatoribus et componentibus systematis assecurans.

Wide Voltage Range: Disponibilis in versionibus DC 600V, 700V, 800V, 1200V, et 1500V.

Robust Design: Casingum naylon flammifugum (UL94 V-0 rated) offert excellentem resistentiam thermalem et environmental.

Flexible Mounting: Supportat installationem per rail et screw, aptum in varias dispositiones cabinetorum DC.

Compact Form Factor: Ideale pro inverteris PV, combiner boxes, et cabinets storage energiae batteriarum limitata spatio.

Main Technical Parameters
DNH50-50
Frame Current (A) 50
Rated Thermal Current lth (A) 50
Insulation Voltage Ui (v) 1500
Rated impulse Withstand Voltage Uimp (kV) 8
DNH50-50
Rated Current (A)
Rated Voltage DC (v) 600 700  800 1000 1200 1500
DC-21B, DC-PV1 2 Layers in Series 50 50  50 40 35 32
DC-PV2 2 Layers in Series 18 18  18 15 13 12
DNH50-50H
Frame Current (A) 50
Rated Thermal Current lth (A) 50
Insulation Voltage Ui (v) 1500
Rated impulse Withstand Voltage Uimp (kV) 8
DNH50-50
Rated Current (A)
Rated Voltage DC (v) 800 1000 1200   1500
DC-21B, DC-PV1 4 Layers in Series 50
DC-PV2 4 Layers in Series 45 40 32   25
 
Rated short-time withstand current law (kA*1s) 0.7
Rated short-circuit-making capacity lcm (kA) 1.5
Mechanical life (cycles) 9700
Electrical life (cycles) 300
Product certification CCC、CE
Operating torque (N*m) 1.5 ~ 2.2
Mounting method Cabinet Door Installation
Protection rating Whole Machine lP20

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum