| Marca | Switchgear parts |
| Numerus Modeli | Commutator fusus DNH1-160/21GR 2P |
| Votum nominatum | AC 400V |
| currus electricus nominatus | 160A |
| Frequenta nominata | 50/60Hz |
| Series | DNH1 |


|
parametri technici |
specificationes | DNH1-250 | DNH1-160 | |||||
| Tensio operativa nominata | Ue | V | AC400 | AC690 | AC400 | AC690 | ||
| Currentis operativi nominati | Ie | A | 250 | 200 | 160 | 100 | ||
| Currentis conventionales calefactionis | Ith | A | 250 | 200 | 160 | 100 | ||
| Currentis circuitus brevis limitati nominati (cum nucleo fusibili) | KA | 100 | 50 | 100 | 50 | |||
| Categoria usus (cum nucleo fusibili) | AC-23B | AC-23B | AC-23B | AC-23B | ||||
| Tensio insulationis nominata | Ui | V | AC1000 | AC1000 | AC1000 | AC1000 | ||
| Tensio impulsionis resistivae nominata | Uimp | KV | 12 | 12 | 12 | 12 | ||
| Frequencia nominata | Hz | 50/60 | 50/60 | 50/60 | 50/60 | |||
| Vita electrica (numero cycli) | times | 200 | 200 | 200 | 200 | |||
| Torque maximus | N.m | 30 | 30 | 20 | 20 | |||
|
Nucleus fusibilis |
Standardes executivi: IEC60269-2/GB/T 13539.2 | 1 | 1 | 00 | 00 | |||
| Currentis operativi nominati | In | A | 200 | 200 | 160 | 100 | ||
| Dissipatio potentiae | Pn | W | 23 | 32 | 12 | 12 | ||
| Conditiones usuales, installationis, et transportationis | Temperatura aeris ambientis | -5℃~+40℃ | ||||||
| Altitudo | ≤2000m | |||||||
| Categoria installationis et gradus pollutionis | Ⅲ、Ⅳ | 3 | ||||||
| Transportation et conservatio | -25℃~+55℃ | |||||||