• Molded case type Intelligent dehumidifier
  • Molded case type Intelligent dehumidifier
  • Molded case type Intelligent dehumidifier
  • Molded case type Intelligent dehumidifier
Molded case type Intelligent dehumidifier
$32.00
Model
ZCS17S-60
ZCS14S-40
ZCS09S-20B
ZCS09S-20A
Basic info
Brand Wone Store
Model NO. Molded case type Intelligent dehumidifier
Rated voltage AC220V+10%
Rated frequency 50/60Hz
Communication port support RS485/RF
Rated power 60W
cabinet type PE
Series ZCS
Product Detail

The semiconductor dehumidifier for switchgear is a reliable assistant to safeguard the stable operation of the switchgear, focusing on dealing with the problem of humidity inside the cabinet. In the power system, due to factors such as high environmental humidity and large temperature differences between day and night, the switchgear is prone to condensation inside. Excessive water vapor not only accelerates the corrosion and aging of electrical components, reduces insulation performance, but in severe cases, it may also cause short - circuit faults, threatening the safety and stability of power supply. This dehumidifier uses semiconductor refrigeration technology and operates based on the Peltier effect. The semiconductor refrigeration sheet inside, when powered on, cools rapidly on one side and heats up on the other side. When the humid air inside the switchgear is sucked into the dehumidification air duct by the fan and comes into contact with the cooling surface, the water vapor immediately condenses into liquid water upon cooling and drains out of the cabinet along the water guide pipe. The air passing through the heating surface has a slightly increased temperature and returns to the cabinet in a dry state, avoiding negative impacts caused by temperature differences. The semiconductor dehumidifier for switchgear has multiple practical features. It has low energy consumption, is energy - saving and environmentally friendly, and effectively reduces operating costs. It is small in size, light in weight, and easy to install, and can be flexibly adapted to the spatial layouts of various switchgears. At the same time, some products are equipped with high - precision humidity sensors and intelligent control systems, which can accurately monitor the humidity inside the cabinet in real - time. Once the humidity exceeds the preset safe range, the dehumidification operation is automatically started, and when the humidity reaches the standard, it stops automatically, achieving intelligent and unattended high - efficiency dehumidification, and creating a dry and stable operating environment for the switchgear in all aspects. Some models also come with a communication function and can be connected to the background monitoring system through the RS485 interface. Maintenance personnel can remotely and real - time monitor the operating status of the dehumidifier and the humidity data inside the cabinet, which is convenient for timely fault diagnosis and maintenance management, further improving the intelligence level and safety of power equipment operation and maintenance.

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Documents
Restricted.
ZCS Series Intelligent dehumidifier series
White paper English
Consulting
Related Products
Related Knowledges
Research and Application of Communication Security Strategies for Smart Meters
Research and Application of Communication Security Strategies for Smart Meters
1. Security Threats Facing Smart Meter Communications1.1 Physical Layer Security ThreatsPhysical layer security threats refer to factors that damage or interfere with the hardware devices and physical connections of smart meters, directly affecting their normal operation and data transmission. From the perspective of equipment damage, harsh natural environments such as lightning strikes, floods, and earthquakes can directly destroy the hardware circuits and structures of smart meters, rendering
Echo
09/01/2025
Analysis of Issues and Causes in Smart Meter Testing
Analysis of Issues and Causes in Smart Meter Testing
1. Issues and Cause Analysis in Smart Electricity Meter TestingDuring the verification of smart electricity meters, inspections must be conducted on the meter’s appearance, as well as the clarity and integrity of nameplate markings. Additionally, careful checks are required for physical damage and whether the display can show digits completely. A power-on inspection is also necessary. If error codes appear on the display after power-up, faults should be identified and addressed according to the
Oliver Watts
09/01/2025
Analysis of Common Operational Fault Causes in Smart Electricity Meters
Analysis of Common Operational Fault Causes in Smart Electricity Meters
With the continuous development of smart grids, smart electricity meters are being increasingly widely applied, and various types of operational faults in smart meters are frequently encountered in energy measurement work. This paper analyzes the causes of smart meter failures and proposes corresponding solutions, using several actual operational fault cases as examples.1. Black ScreenA black screen refers to a powered meter with no display, which is the most commonly occurring fault in field-op
Felix Spark
09/01/2025
What tests are required for a qualified smart electricity meter?
What tests are required for a qualified smart electricity meter?
In today's world, not wearing a watch is no longer unusual, but not having an electricity meter is a serious issue. As a measuring instrument vital to people's daily lives, the electricity meter is an essential tool for power consumption measurement and billing in every household. According to current national strategic requirements for smart grid development, smart electricity meters have been widely applied and promoted, bringing entirely new and extensive market opportunities to the metering
Oliver Watts
09/01/2025
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
1 Analysis of Smart Meter Faults and Their Impact on the Power Grid1.1 Introduction to Smart Meter Functions and Their Critical Role in Modern Power GridsSmart meters exchange data in real time with power companies through two-way communication, enabling functions such as remote meter reading and dynamic tariff adjustment. This capability allows users to adjust their consumption based on real-time pricing, achieving energy savings and cost reduction. Meanwhile, smart meters support grid automati
Felix Spark
09/01/2025
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Meter reading, verification, and billing are critical operations for power companies, and their efficiency directly impacts the company's sustainable development. In recent years, with the widespread adoption of intelligent technologies, smart meters have been promoted and applied in power companies, driving transformation in meter reading and billing operations. The integrated application of smart meters and meter reading, verification, and billing information systems has become a key developme