Transformator Terrenalis Immersus Olei Trifasus 66kV

  • Customization 66kV 88kV 110kV 132kV Three Phase Z-type winding Oil-Immersed Earthing Transformer source manufacturer

Attributa principalia

Marca ROCKWILL
Numerus Modeli Transformator Terrenalis Immersus Olei Trifasus 66kV
Votum nominatum 66kV
Numerus phaseorum Three-phase
Series JDS

Descriptiones productorum a fornitori

Descriptio

Product Overview
Rockwill praebet terrae transformatores fideles et alta performance ad systemata electrica 66kV. Nostri transformatores olei imbibiti sunt constructi ut solutiones stabiles neutralis terrae praebant, simulque securitatem operationis et protectionem systematis assecurant. Facti secundum normas internationales, inter quas IEC et GB, hii transformatores materias optimas et controllem qualitatis rigorem per productionem integram incorporant.

Basic Info.

Key Features

  • Voltage Class: Systema voltage 66kV (200 BIL)

  • Capacity Range: Unitates standard ab 100kVA ad 10,000kVA

  • Winding Configuration: Design zigzag (ZNyn) optimizatus

  • Cooling System: Optiones refrigerationis ONAN/OFAF

  • Insulation: Fluidus mineralis olei vel ester syntheticus

  • Construction:

    • Cista corrugata vel radiator refrigerans

    • Optiones hermeticiter clausae vel cistae conservatoriae

    • Nucleus ferri silicis CRGO

    • Involutio aenea/argentea

Technical Advantages

  • Enhanced Safety: Relais Buchholz integratum et dispositivum liberationis pressionis

  • Low Impedance: Impedentia sequentia zero <15&Omega; pro gestionibus currentis defectus effectivis

  • Durability: Systema picturae resistentiae corrosioni pro installationibus exteris

  • Efficiency: Perdita sine onere reducta per designum nucleum optimizatum

  • Flexibility: Mutator tap off-circuit (&plusmn;5% in gradibus 2.5%)

Typical Applications

Utility Networks:

  • Terrae neutralis pro systematibus transmissionis 66kV

  • Connectiones coil suppressionis arcus

  • Systemata terrae resistivitatis

 Industrial Plants:

  • Facilitates petrochemical

  • Operationes minationis

  • Plantae manufacturae ferri

Renewable Energy:

  • Stationes collector ventorum

  • Substationes PV solaris

  • Plantae hydroelectricae

Performance Specifications

  • Temperature Range: -30&deg;C ad +40&deg;C ambientis

  • Humidity: &le;95% mensis media

  • Altitude: Usque ad 2000m ASL

  • Sound Level: &le;75dB ad 1m

  • Efficiency: &ge;99.2% sub onere pleno

Testing Protocol
All units undergo comprehensive testing including:

  • Measurement impedentiae sequentiae zero

  • Test overvoltage inducendus (260Hz)

  • Test impulsus fulminis (350kV)

  • Test incrementi temperature (max. 65K)

  • Test dielectricae fortitudinis olei (&ge;50kV)

Service Conditions

  • Idoneus pro installationibus interioribus/exteris

  • Resistentia venti usque ad 35m/s

  • Ambientia non explosiva

  • Capacitas seismic: 0.3g acceleratio horizontalis

FAQ
Q: Quid est transformator terrae, et quae sunt eius functiones praecipuae
A:

Transformator terrae/terram coniungens est species specialis transformatoris qui punctum neutrum artificialiter creat pro systematibus electricitatis non-terrae-coniunctis vel terra-coniunctis parvi-curentibus. Per designum involucrum specificum circuitum terrae coniungit, duabus functionibus cardinalibus: primo, ut viam impedimenti parvuli praebet cursum currens sequentiae nullae in systemate, adhibita ut cum culpa unius phase terrae eveniat, currens culpae attingat limen operativum dispositivi protectionis relaevi, faciens ut celeriter locus culpae detegatur et isolari possit; secundo, ut aequilibrium tensionis systematis conservetur, excessus tensionis phasium non-culpabilium in culpa comprimatur, et tecta insulatoria apparatorum rete electricitatis tueatur. Diversum a transformatoribus electricitatis ordinariis, eius functio cardinale est "circuitum terrae coniungere" potius quam "transformationem tensionis", et saepe secundum capacitatem oneris brevis temporis, non secundum capacitatem operationis continua, designatur.

Q: Quid sunt differentiae fundamentales inter transformatores earthing/grounding et transformatores electricitatis ordinarios?
A:

Differentiae inter duas ab essentiali differentia in positione functionali oriuntur, specialiter reflectentes in tribus aspectibus: ① Functiones cordales diversae: transformatores electricitatis communes in transformatione tensionis et transmissione energiae insistunt, dum transformatores earthing/grounding in constructione puncti neutralis et provisione viarum currentis fault; ② Calibrazione capacitas diversa: transformatores electricitatis communes cum capacitate operationis continua (capacitate oneris longi temporis) marcantur, dum transformatores earthing/grounding cum capacitate nominata brevi temporis (capacitate quae intra tempus specificatum per currentem fault et tempus sustinendi, sicut 30 secundorum, ferri potest); ③ Designa involutionum diversa: transformatores earthing/grounding plerumque structuras involutionum speciales ut zigzag (ZN) adhibent, dum transformatores electricitatis communes principale involutiones consuetas ut stellam et triangulum adhibent, et transformatores earthing/grounding saepe non habent rationem transformationis tensionis traditionalem.

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Impactus Praejudicialis Bias Directi Currentis in Transformeribus ad Stationibus Energiae Renovabilis Proximis Electrodis Terrae UHVDC
    Impactus DC Bias in Transformeribus ad Stationes Energeticae Renovabiles Proximas Electrodis Terrae UHVDCCum electrum terrae systematis transmissionis Ultra-Alta-Voltura Directa (UHVDC) sit prope stationem energeticae renovabilis, currus reditus per terram fluens potest causare incrementum potentialis terrae circa aream electri. Hoc incrementum potentialis terrae ducit ad mutationem potentialis puncti neutri transformatorum proximorum, inducendo bias DC (vel offset DC) in eorum nucleis. Talis bi
    01/15/2026
  • HECI GCB for Generators – Cepus SF₆ Circuit Breaker
    1. Definitio et Functio1.1 Munus Interruptoris Circuiti GeneratorisInterruptor Circuitus Generatoris (GCB) est punctum disiunctionis controllabile situatum inter generator et transformator incrementalis, servans ut interficium inter generator et rete electricitatis. Principales eius functiones includunt isolationem defectuum lateris generatoris et facilitationem controlis operationis durante synchronizatione generatoris et connectione ad rete. Principium operativum GCB non differt significanter
    01/06/2026
  • Apparatus Distributionis Transformatorisque Experimentatio Inspectio et Conservatio
    1. Manutentio et Inspectio Transformatoris Aperi interruptorem circuitus bassae tensionis (LV) transformatoris in manu, remove fusum alimenti controlis, et pende signum “Noli Claudere” super manubrium commutationis. Aperi interruptorem circuitus altae tensionis (HV) transformatoris in manu, claudi commutatorem terrae, exsolvare totaliter transformatorem, claude armarium interruptoris HV, et pende signum “Noli Claudere” super manubrium commutationis. Pro manutentione transformatoris sicci: primo
    12/25/2025
  • Quomodo Resistentiam Isolationis Transformatorum Distributionis Probes
    In operibus practicis, resistentia insulationis transformatorum distributionis saepe bis metitur: resistentiam inter spiram alti voltaginis (HV) et spiram bassi voltaginis (LV) plus vasum transformatoris, et resistentiam inter spiram LV et spiram HV plus vasum transformatoris.Si ambae mensurationes valores acceptabiles praebent, indicat quod insulatio inter spiram HV, spiram LV, et vasum transformatoris est probata. Si una mensuratio deficiat, testes pairwise resistentiae insulationis inter omne
    12/25/2025
  • Principia Design pro Transformeribus Distributionis in Columna Fixis
    Principia Design Pro Distributionibus Transformerum in Polum Fixis(1) Principia Locorum et DispositionumPlataformae transformerum in polum fixarum debent collocari iuxta centrum oneris aut prope onera critica, secundum principium “parva capacitas, plura loca” ad facilitatem substitutionis et maintenance. Ad distributionem electricitatis domesticam, transformatores triphasici possunt instaurari iuxta necessitatem praesentem et projectiones futurorum incrementorum.(2) Selectio Capacitatis pro Tran
    12/25/2025
  • Solutio Controlis Stridoris Transformatorum pro Diversis Installationibus
    1. Mitigatio sonoris pro camera transformatoris independente in superficie terraeStrategia mitigationis:Primum, fac inspectionem et maintenance cum potestate interrupta, includens renovationem olei insulantis vetustatis, examinationem et consolidationem omnium fixorum, et mundationem pulvis a unitate.Deinde, reficere fundamentum transformatoris vel installare dispositiva isolationis vibrationis—ut gommae vel isolatores springalis—selecta secundum gravitatem vibrationis.Tandem, fortificare insula
    12/25/2025

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Instrumenta Libera Cognata
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum