Transformatores Fornacis Electrici Immersi in Oleum 10kV 35kV IEE-Business

  • Customization 10kV 17.5kV 30kV 35kV Three phase Oil-Immersed Electric Furnace Transformers

Attributa principalia

Marca ROCKWILL
Numerus Modeli Transformatores Fornacis Electrici Immersi in Oleum 10kV 35kV IEE-Business
Votum nominatum 35kV
Frequenta nominata 50/60Hz
Capacitas nominata 8000kVA
Series HSSP

Descriptiones productorum a fornitori

Descriptio

Product Overview

Fornax electrica transformator est designata ad deprimendum tensionem rete ad tensionem operativam quae fornis electricis necessaria est praebendo currentem alti et bassi voltai pro usibus sicut fornaces ferri efficiendi fornaces leguminis furnaces resistivitatis et fornaces salis balnei.

Nostri transformatores fornis electrici characterizantur per stabilem et fidelem suppeditationem potentiae robustam resistentiam circuitus brevis et excellentem stabilitatem thermicam.

Characteres Producti

  • Robusta Resistentia Circuitus Brevis: Possidet robustam resistentiam circuitus brevis. Cum circuitus brevis occurrat in rete potentiae aut apparatu potest efficaciter impetum sustinere securitatem sui apparati et systematis fornis electrici asserendo.

  • Excellentissima Stabilitas Thermica: Habet bonam stabilitatem thermicam. Potest performance stabiliter manutenere in operatione longa sub alta onera vel in ambientibus calidis vita utilitatis sui apparati extendendo.

  • Lata Scena Applicationis: Adapta est variis generibus fornicium electricorum sicut fornaces ferri efficiendi fornaces leguminis furnaces resistivitatis et fornaces salis balnei et potest necessitates electricas diversarum metallurgicarum et calefactoriarum processuum satisfacere cum scena applicationis maxime lata.

Parametri Technici HSSP Oleo-Immersi Transformatoris Fornacis Electricae

Product Model

Rated Capacity (kVA)

Connection Group Label

Primary Voltage (kV)

Secondary Voltage (V)

Tap Changer Level

Secondary Rated Current (A)

External Series Reactor (kVar)

Short-Circuit Impedance (%)

Weight (kg)

Outline Reference Dimensions (Length * Width * Height mm)

Core Weight

Oil Weight

Total Weight

HSSP-4000/10

4000

Dd0,Yd11 (Primary Corner Transformation)

10

240;138;121;210

4

9630

340

8.5

4600

2600

11800

3400 * 1700 * 2600

HSSP-4000/35

4000

35

240;139;121;210

4

9626

340

8.5

5300

3300

13500

3600 * 1500 * 3100

HSSP-4200/10

4200

10

240;138;129;224;210;121

6

10112

360

8.5

4700

2600

12000

3400 * 1700 * 2600

HSSP-4200/35

4200

35

240;138;129;224;210;121

6

10107

360

8.5

5500

3400

13800

3600 * 1500 * 3100

HSSP-5000/10

5000

10

240;139;121;210

4

12028

430

8.5

5300

2800

13000

3400 * 1700 * 2700

HSSP-5000/35

5000

35

240;139;121;210

4

12032

430

8.5

6100

3600

14800

3800 * 2000 * 3200

HSSP-5500/10

5500

10

260;150;139;240;210;121

6

12208

450

8.5

6100

3400

14600

3700 * 2000 * 2800

HSSP-5500/35

5500

35

260;150;139;240;210;121

6

12218

450

8.5

6900

4200

16400

3800 * 2000 * 3400

HSSP-6300/10

6300

10

260;150;139;240;210;121

6

13983

360

7.5

6700

3600

15400

3600 * 2000 * 3000

HSSP-6300/35

6300

35

260;150;139;240;210;121

6

13991

360

7.5

7500

4300

17100

3800 * 2000 * 3400

HSSP-8000/10

8000

10

260;150;139;240;210;121

6

17749

460

7.5

8200

3800

17800

3800 * 2000 * 3000

HSSP-8000/35

8000

35

260;150;139;240;210;121

6

17759

460

7.5

9000

4700

19700

3900 * 2000 * 3200

HSSP-9000/10

9000

Dd0

10

280;260;240;220;200;

180;160;140

8

18576

450

7.5

9900

4700

21700

4000 * 2000 * 3200

HSSP-9000/10

9000

10

290;270;250;230;210;

190;170;150

8

22603

450

7.5

10900

5000

23500

4100 * 2100 * 3200

HSSP-9000/10

9000

10

340;320;300;280;260;

240;220;200

8

18591

450

7.5

10100

4700

22000

4100 * 2000 * 3200

HSSP-9000/35

9000

Yd11

35

280;260;240;220;200;

180;160;140

8

18551

450

7.5

11100

5700

24300

4300 * 2400 * 3600

HSSP-9000/35

9000

35

290;270;250;230;210;

190;170;150

8

22629

450

7.5

11900

5900

25700

4300 * 2400 * 3600

HSSP-9000/35

9000

35

340;320;300;280;260;

240;220;200

8

18579

450

7.5

11500

5800

25200

4300 * 2500 * 3600

Virtutes Producti

  • Adaptatio Precisa Tensionis: Potest accuratam tensionem rete ad tensionem operativam quae ab electricis fornacibus requiritur minuere, satisfaciens exigentiae tensionis variarum electricarum fornacium, sicut fornicum ferri efficiendi, fornicum alliage, fornicum resistivorum et fornicum salis balnearum, securitatem adaptabilitatis aequipmentorum assecurans.

  • Forte Supellex Currentis: Potest potentem currentem bassae tensionis praebere, sufficentem supportum electricum pro processibus altius temperandi, calefaciendi et aliorum fornicum electricorum praebens, securitatem efficientiae productionis assecurans.

  • Excellem Qualitatem Suppellectilis Electricae: Qualitas suppeditationis electricae est stabilis et fidelis, evitans impactum fluctuationum tensionis super operationem fornicum electricorum et qualitatem producti, et auxiliatur ut securitas et controllabilitas processus productionis obtineantur.

10kV 35kV Oil-Immersed Electric Furnace Transformers.png

10kV 35kV Oil-Immersed Electric Furnace Transformers

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Instrumenta Libera Cognata
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum