Customization 10kV 10.5kV 11kV 11.5kV 15.6kV Single-phase outdoor Automatic Smart recloser/reclosure

  • Customization 10kV 10.5kV 11kV 11.5kV 15.6kV Single-phase outdoor Automatic Smart recloser/reclosure

Key attributes

Brand ROCKWILL
Model NO. Customization 10kV 10.5kV 11kV 11.5kV 15.6kV Single-phase outdoor Automatic Smart recloser/reclosure
Rated voltage 15.6kV
Rated normal current 1250A
Rated short circuit breaking current 25kA
Power frequency withstand voltage 60kV/min
Rated lightning impulse voltage 125kV
manual closing Yes
Series RCW
Description

Description

As a pioneering original equipment manufacturer (OEM) in China’s recloser industry, we have accumulated decades of R&D expertise, taken the lead in establishing the original industry standards, built a fully independent end-to-end production system, and delivered reliable product solutions for power grid construction.

The 10kV 10.5kV 11kV 11.5kV 15.6kV Single-phase outdoor Automatic Smart recloser/reclosure is an intelligent outdoor switching device specifically designed for medium-voltage distribution networks. Using vacuum as the arc-extinguishing medium, this equipment can quickly interrupt fault currents and effectively isolate short-circuits, overloads, and other faults in the distribution grid. It features an automatic reclosing function that restores power supply automatically after fault elimination, significantly reducing power outage time and improving power supply reliability. With its compact and rugged outdoor structure design, it adapts to various harsh natural environments—stable operation in high temperatures, severe cold, high humidity, or sandy conditions—making it a vital device for ensuring safe and efficient operation of medium-voltage power lines.

Key Features

High-efficiency Arc Extinguishing Performance

  • Adopting vacuum arc extinguishing technology, it features strong insulation and rapid arc extinction. It prevents arc reignition, extends the equipment's service life, and reduces maintenance costs.

Precise Automatic Reclosing

  • Automatically closes the circuit according to the preset program. It can distinguish between transient and permanent faults. For transient faults, it restores power supply rapidly; for permanent faults, it locks immediately to minimize the power outage scope.

Excellent Environmental Adaptability

  • With a high-strength and corrosion-resistant outer shell and internal protective treatment, it can operate stably in harsh environments, adapting to temperatures ranging from -40°C to +70°C.

Intelligent Monitoring and Remote Control

  • It can monitor key parameters such as current and voltage in real-time and upload data. Supporting remote opening and closing operations, it improves fault handling efficiency and the intelligent level of grid operation and maintenance.

High Safety and Reliability

  • Equipped with complete mechanical and electrical interlocking devices to prevent misoperation, it has a long-life design with tens of thousands of mechanical operation cycles, ensuring stable power supply.

Parameters

The voltage classes of some of these Automatic Reclosers include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV and 69kV. Rated Short-Circuit Breaking Current includes 8kA, 12.5kA, 16kA, 20kA, 25kA, 31.5kA and customization is available.

Rated maximum voltage

15.6kV

Rated maximum current

1250A

Rated frequency

50Hz

Rated short circuit breaking current

12.5kA

Rated peak value withstand current

31.5kA

Rated 1min power frequency withstand voltage(Single-phase Silicone rubber pole (unable the gas))

60kV

Rated lightning impulse voltage(Single-phase Silicone rubber pole (unable the gas))

125kV

Operation sequence

C-0.5-CO-2-CO-5-CO(Magnetic actuator)

Mechanical life

n:30000(Magnetic actuator)

Power supply and operating voltage

110/220V (Customized)

Ratio of current transformer

400/1A (Customized)

Number of voltage sensors(Single-phase Silicone rubber pole (unable the gas))

≤1

Opening time

≤20ms(Magnetic actuator)

Closing time

≤30ms(Magnetic actuator)

Minimum creepage distance

31, level4(mm/kV)

Minimum distance between phases

360mm

Potential transformer

110/220V (Customized)

Cable length

6,8,12m (Customized)

Cable clamp(Single-phase Silicone rubber pole (unable the gas))

2-hole NEMA

Lightning arrester

≤6

Mounting type

Single / double column

With optional relay protection & logics for user choice

Instantaneous over-current protection

Timing over-current protection

Negative sequence over-current protection

Directional over-current protection(⁽¹⁾)

Over-voltage protection / Under voltage protection

Programmable protection relay curves (total 10 nos ANSI/IEC curves)

Cold load pickup protection TCC + Hot line tag

Earth protection E/F SEF + Zone- Sequence Co-ordination

More relay functions can be customized

With optional communication protocols & I/O port for user choice

RS-232 and RS-485 ports supporting

DNP3.0 communication protocol support

Modbus communication protocol is optional

IEC 60870-501 communication protocol support

IEC 60870-5-104 communication protocol support

The recloser can communicate through GPRS(or) GSM(or) GPRS/GSM module with English or Specified language

With optional functions for use

Rated currents, System phase current,

Rated voltages, System phase voltage and secondary low voltage power supply voltage Frequency

power (kWh), reactive power (kVarh), power factor

With optional reclosing interval for user pre-program

reclosing times setting support

Dead time setting support

With events recording function

SOE 10000 operations record

Fault record and normal operation record

Note:mean should customized by manufacturer if needed

Environmental requirement:

Maximum temperature:

+40°C

Minimum temperature:

-30°C

Monthly average humidity

95%

Humidity:

90%

Above sea level:

2500m or higher

Ambient air Not apparently polluted by corrosive and flammable gas, vapor


What are the technical parameters of the outdoor vacuum recloser?

  • Rated Voltage: 38kV, indicating the voltage level at which the recloser can operate normally. This ensures that the insulation and electrical performance of the device meet the required standards at this voltage.

  • Rated Current: Available in various specifications, such as 800A, 1200A, etc. This represents the maximum current that the recloser can carry continuously during normal operation. The appropriate rated current value should be selected based on the load current of the line.

  • Rated Short-Circuit Breaking Current: Reflects the breaking capability of the recloser during short-circuit faults. Common specifications include 16kA, 20kA, etc. A higher short-circuit breaking current indicates that the recloser can more reliably interrupt short-circuit currents, protecting the safety of the power system.

  • Rated Short-Circuit Making Current: Represents the maximum peak current that the recloser can close during a short-circuit fault. This value is typically greater than the rated short-circuit breaking current to ensure that the recloser can reliably close and withstand the impact of short-circuit currents at the moment of fault.

  • Reclosing Time Interval: Generally adjustable between 0.5 seconds and several seconds. Depending on the requirements of different power systems and types of faults, an appropriate reclosing time interval can be set to enhance the reliability and continuity of power supply.


Case Studies - outdoor vacuum recloser

  • Rockwill Ukraine 186 Units 12kV Outdoor Vacuum Recloser Project Success Case
    In response to the operational characteristics of Ukraine’s local power grid and targeting harsh high-latitude outdoor working conditions, we rely on core technologies of intelligent reclosing and self-healing to precisely adapt to the complex grid environment with frequent thunderstorms and drastic diurnal temperature variations, steadily promoting the automatic and intelligent upgrade of regional rural power grids and suburban distribution networks.01 Project Overview1.1 Project BackgroundIn 2
  • DTEK Grid Upgrade: Operation of Rockwill 10kV Smart Recloser in -40°C Extreme Cold Environment Ukraine Case Study
    As a benchmark for Chinese‑manufactured medium‑voltage distribution equipment going global, Rockwill established in‑depth cooperation with DTEK Kyiv Power Grid, Ukraine. Tailored outdoor vacuum recloser solutions were mass‑deployed to address existing weaknesses in local 10 kV distribution networks, comprehensively improving regional power supply reliability and automation to build a flagship distribution grid modernization project in Kyiv.01 Project Background: Core Pain Points of DTEK Kyiv Dis
  • Successful Case of 170 Sets of 11kV Automatic Recloser Project in Kenya
    Against the backdrop of quality upgrading for Kenya’s urban and rural power grids, 11kV auto-reclosers deliver reliable performance to suit local climates and grid conditions. It enables rapid fault isolation and efficient operation and maintenance, forming a core safeguard for the upgrading of Kenya’s urban and rural distribution networks.01 Project Overview1.1 Project BackgroundIn May 2023, 170 sets of 11kV Automatic Reclosers (Model: RCW12M) were officially supplied and applied to the medium-

Documentation Resource Library outdoor vacuum recloser

Restricted
15kV automatic recloser technology specification 15kV automatic recloser technology specification
Technical Data
English
PDF
Restricted
10 to 38kV auto vacuum break recloser Catalog 10 to 38kV auto vacuum break recloser Catalog
Catalogue
English
PDF
Restricted
15kV/27kV/38kV outdoor auto break vacuum recloser 15kV/27kV/38kV outdoor auto break vacuum recloser
Brochure
English
PDF
Public.
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English

Frequently asked questions

Distribution network faults occur occasionally with long data accumulation cycles. RCW single-phase vacuum reclosers are installed on overhead poles and may only encounter faults once every several months or years.

Conventional controllers can only store hundreds of records and old data will be overwritten by new events. The 10,000-point large-capacity SOE storage prevents the loss of early fault records, preserving complete time-sequenced event logs for later analysis.

Yes, Rockwill provides comprehensive OEM/ODM programs for the RCW single-phase vacuum recloser. To maintain our high quality standards, we partner exclusively with regional manufacturers and distributors who possess robust engineering expertise and local service capabilities.

Our goal is to build strategic alliances that deliver not just premium hardware, but exceptional local technical support for smart grid modernization.

While the ZW32 is a basic circuit breaker requiring an external controller, the RCW is a fully integrated smart grid recloser with built-in protection, sensors, and communication.

Furthermore, the RCW strictly complies with IEC 62271-111 and ANSI C37.60 standards, featuring premium insulation tailored for international distribution automation projects.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register