7.6KVPole Mounted 32 Step Single Phase Oil Immersed Type Voltage Regulator 译为拉丁语: Regulator Voltae Immersae in Oleum Unipolaris Scalae 32 Fixus in Columna 7.6KV

  • Continuous / Step voltage regulation step voltage regulator 6kV 6.35kV 11kV 15kV 22kV 33kV – IEEE

Attributa principalia

Marca ROCKWILL
Numerus Modeli 7.6KVPole Mounted 32 Step Single Phase Oil Immersed Type Voltage Regulator 译为拉丁语: Regulator Voltae Immersae in Oleum Unipolaris Scalae 32 Fixus in Columna 7.6KV
Votum nominatum 11kV
Frequenta nominata 50/60Hz
Numerus phaseorum Single-phase
Series RVR

Descriptiones productorum a fornitori

Descriptio

Product Overview

RVR-1 uniphasis step voltage regulator est autotransformator oleoimmersus cum integrato on-load tap changer, designatus ad automaticam stabilisationem distributionis lineae voltaginis. Offert ±10% regulationem in 32 finibus gradibus (circa 0.625% quilibet), certans consistentiam voltaginis per variabilia conditionia oneris.

Gradus voltaginis ab 2,500V (60 kV BIL) ad 19,920V (150 kV BIL), cum capacitatibus currentis ab 50A ad 1665A et kVA ratingibus ab 38.1 ad 1000. Unitas compatibilis est cum systematis 50Hz et 60Hz et potest instaurari in pole-mounted, pad-mounted, vel in substationibus.

Product Features

  • Precise Voltage Regulation
    ±10% adjustment in 32 automatic steps (approx. 0.625% per step)

  • Digital Controller
    Programmable settings, communication (optional: GPRS/GSM/Bluetooth), and data logging

  • Flexible Installation
    Supports pole mounting with brackets, pad-mount base, or substation mounting with optional elevating platforms

  • Versatile Voltage Matching
    Equipped with internal potential taps or external ratio correction transformer for system compatibility

Key Advantages

  • Certified Quality
    ISO9001 & ISO14001 certified; each unit is fully type-tested before delivery

  • Robust & Reliable
    Built for harsh environments with minimal maintenance requirements

  • Flexible Packaging Options
    Export-grade seaworthy wooden boxes available in single or double-unit formats to reduce shipping cost

  • Professional Support
    Fast pre-sales response, real-time production updates, and long-term after-sales service

Application Scenarios

  • Rural & Urban Distribution Networks
    Compensates for voltage drops along long feeder lines

  • Industrial Zones
    Ensures voltage stability for large machinery and sensitive equipment

  • Renewable Energy Integration
    Maintains voltage stability in grids with wind or solar input

  • Substation Use
    Enhances voltage control across secondary distribution systems

Technical Specifications

Bibliotheca Documentorum Rerum
Restricted
6kV to 34.5kV Single Phase Automatic Voltage Regulator Brochure
Catalogue
English
Consulting
Consulting
FAQ
Q: Quomodo normae IEEE selectionem regulatorum tensionis graduali 33kV tangunt
A:

Standard IEEE C57.15/C57.116 definivit requisitos essentiales pro regulatoribus 33kV:

  • Severitas Experimenti: Imperat tolerationem impulsi fulminis (110kV) et experimenta elevationis caloris (max 55°C)

  • Protocollae Securitatis: Postulat dispositiva delevionis pressionis et tolerationem currentis defectus (25kA/2s)

  • Metricae Praestantiae: Specificat accurateam tensionis ±0.5% et efficaciam minimam 96% a 50-100% oneri

  • Valorem Conformitatis: Modello certificato ab IEEE securitatem compatibilitatis rete et facilitat processus approbationis utilitatis
    Hae standardes directe correlant ad vita servitii longior 20% et costus maintenance reducere 35% in deploymentibus agri.

Q: Quid est differentia inter regulam tensionis continuam et gradatim in regulatoribus tensionis gradatim?
A:

Regulatores tensionis graduali duos modos distinctos correctionis tensionis praebent:

  • Regulatio Gradualis: Tensionem in incrementis fixis (typice ±10% in gradu 0.625-1.25%) per mutatores tap adiustat. Idonea pro reticulis stabilibus ubi adiustamenta accurata sufficient.

  • Regulatio Continua: Correctionem lenem, sine gradibus, per conversionem electronicae potestatis praebet. Perfecta pro reticulis volatilibus cum fluctuationibus frequentibus (exempli gratia, zonas integrationis renovabilium).
    Omnes formae (6kV-33kV) normis IEEE C57.15 obtemperant, cum versiones gradualis 32 positiones mutatorum tap et versiones continuae ±1% accurate output sub omnibus conditionibus oneris conservantes.

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Instrumenta Libera Cognata
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum