• HVS Series Generator circuit-breakers
HVS Series Generator circuit-breakers
discuss personally
Model
HVS-63S
Basic info
Brand ROCKWILL
Model NO. HVS Series Generator circuit-breakers
Rated voltage 24kV
Rated normal current 6900A
Rated frequency 50/60Hz
Rated short circuit breaking current 63kA
Series HVS Series
Product Detail

Overview

Innovative breaking chamber

The breaking chamber of HVS-63S is based on the highly reliable technology of open-type GCB HVR-63. The breaking chamber includes the double main contacts for double current commutation for higher stability of resistance to ensure the maintenance span of 20 years or 10,000 close-open operations. Featuring the advantage of a hydraulic spring operating mechanism, HMB-1, it uses 50 percent less energy compared to mid-sized GCBs for a more compact design and lower lifecycle costs.

Pressure relief device

Standard feature in the breaking chamber to improve safety and availability.

Erosion monitoring system

The breakthrough application of head-to-head contact system in HVS-63S enables an innovative built-in mechanical solution for a direct measurement and indication of arcing contact erosion. This real-time indication of the remaining time to service enables a timely planning of maintenance and increases the availability and reliability of the plant.

The most reliable spring drive HMB-1

CIGRE study (conducted in 2012) on high-voltage circuit breaker failures and defects in service revealed that the availability of the circuit breakers depends primarily on the reliability of the operating mechanism. These results from the study have endorsed the hydro mechanical spring drive as the most reliable operating mechanism for GCB applications. The hydraulic spring operating mechanism combines the advantages of a hydraulic operating mechanism with those of spring energy storage system with higher stability in the full range of the GCB operating temperatures and high consistency of timing during the entire lifespan for a safe performance.

Combined disconnector-earthing switch and earthingswitch-starting switch

Combination of line disconnector with earthing switch andearthing switch with starting switch by three-positions disconnector allows the use of only one drive per disconnector for the lowest lifecycle cost, simplification of the switchgear and leaner management of the spare parts.

Low environmental impact

Only 5.1 kg of SF6 in three poles and a leakage rate lower than 0.1 percent per year. The advanced functions of GMS600 monitoring system, such as SF6 and temperature monitoring and trending (available on request), facilitates the control of such parameters.

Additional safety features

By using an advanced Geneva mechanism and key locks system, the design of the disconnector drives ensures full flexibility in implementation of the interlocking needs of the power plant. Special care in the encapsulation of the pole frame assures protection from unintentional access to moving parts between operating mechanism and switching components for the highest safety of operators & maintenance engineers. The breaking chamber technology from HVR-63 with very fast opening time assures the clearance of potential harmful faults in tens of milliseconds for higher protection of power plant assets.

Type-tested according to latest standards

HVS-63S is type-tested according to the latest standards for GCB, including switching with full-phase opposition fault current (180° out-of-phase). Moreover, it is type-tested to interrupt current exhibiting delayed current zeros up to 130 percent degree of asymmetry, which are typical for turbo generators. The above capabilities exceed the mandatory requirements of the latest GCB standard and IEEE C37.013.

Compact design and easy handling

HVS-63S is fully assembled and tested at the factory for substantial cost and time saving in installation and commissioning process. Its compact design fits into standard 20-feet container for easy transportation, handling and storage. Combined with its plug-in system it leads to a simpler and quicker installation on-site.

Technology parameters

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Research and Application of Communication Security Strategies for Smart Meters
Research and Application of Communication Security Strategies for Smart Meters
1. Security Threats Facing Smart Meter Communications1.1 Physical Layer Security ThreatsPhysical layer security threats refer to factors that damage or interfere with the hardware devices and physical connections of smart meters, directly affecting their normal operation and data transmission. From the perspective of equipment damage, harsh natural environments such as lightning strikes, floods, and earthquakes can directly destroy the hardware circuits and structures of smart meters, rendering
Echo
09/01/2025
Analysis of Issues and Causes in Smart Meter Testing
Analysis of Issues and Causes in Smart Meter Testing
1. Issues and Cause Analysis in Smart Electricity Meter TestingDuring the verification of smart electricity meters, inspections must be conducted on the meter’s appearance, as well as the clarity and integrity of nameplate markings. Additionally, careful checks are required for physical damage and whether the display can show digits completely. A power-on inspection is also necessary. If error codes appear on the display after power-up, faults should be identified and addressed according to the
Oliver Watts
09/01/2025
Analysis of Common Operational Fault Causes in Smart Electricity Meters
Analysis of Common Operational Fault Causes in Smart Electricity Meters
With the continuous development of smart grids, smart electricity meters are being increasingly widely applied, and various types of operational faults in smart meters are frequently encountered in energy measurement work. This paper analyzes the causes of smart meter failures and proposes corresponding solutions, using several actual operational fault cases as examples.1. Black ScreenA black screen refers to a powered meter with no display, which is the most commonly occurring fault in field-op
Felix Spark
09/01/2025
What tests are required for a qualified smart electricity meter?
What tests are required for a qualified smart electricity meter?
In today's world, not wearing a watch is no longer unusual, but not having an electricity meter is a serious issue. As a measuring instrument vital to people's daily lives, the electricity meter is an essential tool for power consumption measurement and billing in every household. According to current national strategic requirements for smart grid development, smart electricity meters have been widely applied and promoted, bringing entirely new and extensive market opportunities to the metering
Oliver Watts
09/01/2025
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
1 Analysis of Smart Meter Faults and Their Impact on the Power Grid1.1 Introduction to Smart Meter Functions and Their Critical Role in Modern Power GridsSmart meters exchange data in real time with power companies through two-way communication, enabling functions such as remote meter reading and dynamic tariff adjustment. This capability allows users to adjust their consumption based on real-time pricing, achieving energy savings and cost reduction. Meanwhile, smart meters support grid automati
Felix Spark
09/01/2025
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Meter reading, verification, and billing are critical operations for power companies, and their efficiency directly impacts the company's sustainable development. In recent years, with the widespread adoption of intelligent technologies, smart meters have been promoted and applied in power companies, driving transformation in meter reading and billing operations. The integrated application of smart meters and meter reading, verification, and billing information systems has become a key developme
Echo
09/01/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!