Series CJX8(B) Contactor in Circuitis AC 50/60Hz

  • CJX8(B) Series AC Contactor in 50/60Hz Circuits

Attributa principalia

Marca Switchgear parts
Numerus Modeli Series CJX8(B) Contactor in Circuitis AC 50/60Hz
currus electricus nominatus 16A
Frequenta nominata 50Hz
Series CJX8(B)

Descriptiones productorum a fornitori

Descriptio

Applicatio

Series CJX(B) contactor electricus ad circuitum AC 50Hz (vel 60Hz), tensionem operativam nominalem usque ad 660V et currentem operativam nominalem usque ad 370A, ad circuitum faciendum et rumpendum a longe, potest etiam formari in starter electromagneticum cum rele thermico supercargae adaequato ad circuitum protegendum contra
possibilem supercargam.

Producta sunt conformia standardibus sicut GB 14048.4 et IEC 60947-4-1.

Principalia Data Technica

Type

Frame code

Rated insulation Voltage

Conventional thermal current

Rated working current - 380V

Rated working current - 660V

Max power of controllable motor - 380V

Max power of controllable motor - 660V

Operating frequency time/h - AC-3

Operating frequency time/h - AC-4

CJX8(B)-9

16

690

16

8.5

3.5

4

3

600

300

CJX8(B)-12

16

690

20

11.5

4.9

5.5

4

600

300

CJX8(B)-16

16

690

25

15.5

3.7

7.5

5.5

600

300

CJX8(B)-25

25

690

40

22

13

11

11

600

300

CJX8(B)-30

30

690

45

30

17.5

15

15

600

300

CJX8(B)-37

45

690

45

37

21

18.5

18.5

600

300

CJX8(B)-45

45

690

60

44

25

22

22

600

300

CJX8(B)-65

85

690

80

65

44

33

40

600

300

CJX8(B)-85

85

690

100

85

55

45

50

600

300

CJX8(B)-105

105

690

140

105

82

55

75

600

150

CJX8(B)-170

170

690

230

170

118

90

110

600

150

CJX8(B)-250

250

690

300

245

170

132

160

400

100

CJX8(B)-370

370

690

410

370

268

200

250

400

100

Dimensio Externa et Magnitudo Installationis

Typus

A

B max

C

D

E

F

G

H min

CJX8(B)-105

118

154

137

140

35

6.5

6.5

15

CJX8(B)-170

134

165

152

150

40

6

7.5

15

CJX8(B)-250

167

207

193

190

50

7

8.5

15

CJX8(B)-370

202

252

221

220

60

7

8.5

15


Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum