• 40.5kV HV Vacuum SF6 circuit breaker
40.5kV HV Vacuum SF6 circuit breaker
discuss personally
Model
ZW39-40.5/2500-31.5
ZW39-40.5/2000-31.5
Basic info
Brand Wone
Model NO. 40.5kV HV Vacuum SF6 circuit breaker
Rated voltage 40.5kV
Rated normal current 2500A
Rated frequency 50Hz
Rated short circuit breaking current 31.5kA
Series ZW39-40.5
Product Detail

Product introduction:

ZW39-40.5 vacuum circuit breaker is applicable in the 50Hz,40,5kV three-0hase electrical system and it is used forbreaking rated current, failure current or switching lines and realize the control and protection of electrical system,This product can be frequently operated and can also be used as a connection breaker.

Main characteristic:

  • The optimized choice of vacuum interrupter contact materials keeps the breaking interception value under 4A on average, effectively inhibiting operation overvoltage.

  •  The circuit breaker has strong breaking capacity and the breaking short-circuit current 31.5kV can reach 30 times.

  •  Equipped with CT34 improved spring operating mechanism, using cast aluminum base, good stability, mechanical life of more than 10000 times. Main features of CT34 improved structure (compared with original CT10A structure).

    (a)The energy storage system adopts floating tooth structure. After closing, the remaining energy of the closing spring will continue to store energy and act as the closing buffer. There is no void, the energy storage time is short, and the energy storage can be in place within 8S;

    (b)Operating mechanism adopts high strength cast aluminum frame, which has high strength, no welding stress and nigh anti-corrosion performance;

    (c)The opening and closing spring and buffer are arranged in a centralized way, with compact structure and beautiful appearance;

    (d)Imported Krupp NB52 grease is used for the mechanism, which is resistant to low temperature and not easy to harden, and is suitable for -50℃~+55°℃ area;

    (e)The mechanism adopts oil buffer, small operation impact, small brake rebound.

  •  This product can meet the environment requirements for a sea level of up to 3000m; with a high insulation level, the insulation level at broken sections reaches 118kV;

  • The circuit breaker may have internally or externally attached transformers. Four internally attached transformers can be attached to each phase of the circuit beaker and the iron core of the internally attached transformer adopts microcrystal alloy and magnetic material with high conductivity, and the electrical transformers above 200A can reach Grade 0.2 or Grade0.2S. The integrated structure of the circuit breaker is compact, and the binding techniques for the secondary windings of transformers have been fully optimized, which fully ensures that after binding the coils of the transformer has regular shape, free of burrs, and they will not become loosen at baking and not deformed after they are installed into the main unit, thus ensuring even electrical field.

  •  The internally attached CT of the circuit breaker is compact, but due to the limited space inside the circuit breaker, it cannot realize very high accuracies (for example 0.2 or 0.2s. ) at small currents (such as those below 100A), and it also has small load. ln addition, the maintenance, capacity increase and replacement of internally attached current transformer is not convenient compared with those of the externally attached transformer.

  •  In the space between the vacuum interrupter and the ceramic sleeve of this product is filled with SF6 gas (without internally attached CT: 0.02MPa, with internally attached CT: 0.2pa), ensuring that no internal condensation and moisture absorption will occur,

  •  Imported products or products made by joint venture manufacturers were adopted for major secondary electric components, so they feature high reliability.

  • The surface treatments for the exposed parts of this product were al hot dip galvanized or directly use high quality stainless steel plates, which feature excellent corrosion resistance.

Main technical parameters:

1732503263140.png

Order notice :

  • Types and specifications of circuit breakers;

  • Rated electrical parameters (voltage, current and breaking current, etc.);

  • Ambient conditions (ambient temperatures, sea levels and grades of environmental pollution level);

  • Operating voltage and motor voltage of operating mechanism;

  • Number, current ratios, scale order combination and secondary load of internally or externally attached transformer;

  •  Spare parts and specialized tools, names and quantity of equipment (need to be ordered separately).

How does a vacuum SF6 circuit breaker work?

Closing Process:

  • Closing Process: When the operating mechanism receives a closing command, it drives the moving contact towards the stationary contact until they make contact and close tightly, thus completing the circuit. During the closing process, the contact pressure between the contacts must reach a certain value to ensure good electrical conductivity and mechanical stability, preventing issues such as overheating and loosening of the contacts during operation.

Opening Process:

  • Opening Process: During the opening process, the operating mechanism rapidly moves the moving contact away from the stationary contact, creating an arc between the contacts. At this point, the insulating medium in the arc quenching chamber (such as sulfur hexafluoride gas) rapidly decomposes and ionizes under the high temperature of the arc, forming a plasma. The positive and negative ions in the plasma move in opposite directions under the influence of the electric field, causing the arc to cool and stretch, ultimately leading to its extinction and the disconnection of the circuit.


Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Research and Application of Communication Security Strategies for Smart Meters
Research and Application of Communication Security Strategies for Smart Meters
1. Security Threats Facing Smart Meter Communications1.1 Physical Layer Security ThreatsPhysical layer security threats refer to factors that damage or interfere with the hardware devices and physical connections of smart meters, directly affecting their normal operation and data transmission. From the perspective of equipment damage, harsh natural environments such as lightning strikes, floods, and earthquakes can directly destroy the hardware circuits and structures of smart meters, rendering
Echo
09/01/2025
Analysis of Issues and Causes in Smart Meter Testing
Analysis of Issues and Causes in Smart Meter Testing
1. Issues and Cause Analysis in Smart Electricity Meter TestingDuring the verification of smart electricity meters, inspections must be conducted on the meter’s appearance, as well as the clarity and integrity of nameplate markings. Additionally, careful checks are required for physical damage and whether the display can show digits completely. A power-on inspection is also necessary. If error codes appear on the display after power-up, faults should be identified and addressed according to the
Oliver Watts
09/01/2025
Analysis of Common Operational Fault Causes in Smart Electricity Meters
Analysis of Common Operational Fault Causes in Smart Electricity Meters
With the continuous development of smart grids, smart electricity meters are being increasingly widely applied, and various types of operational faults in smart meters are frequently encountered in energy measurement work. This paper analyzes the causes of smart meter failures and proposes corresponding solutions, using several actual operational fault cases as examples.1. Black ScreenA black screen refers to a powered meter with no display, which is the most commonly occurring fault in field-op
Felix Spark
09/01/2025
What tests are required for a qualified smart electricity meter?
What tests are required for a qualified smart electricity meter?
In today's world, not wearing a watch is no longer unusual, but not having an electricity meter is a serious issue. As a measuring instrument vital to people's daily lives, the electricity meter is an essential tool for power consumption measurement and billing in every household. According to current national strategic requirements for smart grid development, smart electricity meters have been widely applied and promoted, bringing entirely new and extensive market opportunities to the metering
Oliver Watts
09/01/2025
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
1 Analysis of Smart Meter Faults and Their Impact on the Power Grid1.1 Introduction to Smart Meter Functions and Their Critical Role in Modern Power GridsSmart meters exchange data in real time with power companies through two-way communication, enabling functions such as remote meter reading and dynamic tariff adjustment. This capability allows users to adjust their consumption based on real-time pricing, achieving energy savings and cost reduction. Meanwhile, smart meters support grid automati
Felix Spark
09/01/2025
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Meter reading, verification, and billing are critical operations for power companies, and their efficiency directly impacts the company's sustainable development. In recent years, with the widespread adoption of intelligent technologies, smart meters have been promoted and applied in power companies, driving transformation in meter reading and billing operations. The integrated application of smart meters and meter reading, verification, and billing information systems has become a key developme
Echo
09/01/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!