• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


100kVA 120kVA 150KVA 315kVA 630kVA Neutral Grounding/earthing Transformer Dry Type Power Transformer

  • 6kV 6.3kV 6.6kV 10kV 10.5kV 11kV Neutral Grounding/earthing Transformer Dry Type Power Transformer direct supply

Attributa principalia

Marca ROCKWILL
Numerus Modeli 100kVA 120kVA 150KVA 315kVA 630kVA Neutral Grounding/earthing Transformer Dry Type Power Transformer
Votum nominatum 11kV
Frequenta nominata 50/60Hz
Capacitas nominata 630kVA
Series DKSC

Descriptiones productorum a fornitori

Descriptio

Descriptio

Transformatores electrici sicci potentiis 100-630kVA cum fundamento neutrale, quibus resina epoxy infunditur, praebent excellentem isolationem, ignifugam et humiditatis resistens. Per puncta neutralia stabilientia, efficaciter anulorum suppressionis vel resistorum ad terram connectunt, ut celeriter cursus fault terrae retei suppressant, fidelitatem suppeditationis electricae augeant. Idonei sunt pro retibus distributionis 10kV/35kV, centris datarum, aedificiis commercialibus, etc.

 Advantagia Producti:

Designati ut in exigentibus scenariis distributionis electricitatis excellant, nostri transformatores technologiam novissimam integrant, ut fidem et operationem sine pari praebere possint.

  • Dispersio Partialis Ultra-bassa: Cum dispersione partiali ≤ 10 pC, nostri transformatores minuunt stress electricus et degradatio isolationis, stabilitatem operationis longinqua tempore assecurantes et periculum deficiendi prae maturitate reducendo.

  • Adaptabilitas Frigoris Extremi: Capaces operandi ad temperaturis bassis usque ad -25°C, hii transformatores perfomantiam fidelem in mediis duris servare valent, eos idoneos faciens pro regionibus frigidis et installationibus externis.

  • Classifications Performance Optima: Graduati E3 (Resistentia Aetatis Exceptionalis), C3 (Resistentia Contaminationis Alta), et F1 (Emissio Soni Bassa), nostra producta standarda industriae summa pro durabilitate, adaptabilitate, et compatibilitate ambientali complent.

  • Auctus Temperaturae Minimus: Constructi ut auctus temperaturae bassus (100K - 125K) etiam sub oneribus gravis attineant, hi transformatores efficiam energiae optimizant, vitam servicii extendant, et requisita maintenance minuunt.

  • Tolerantia Electrica Robusta: Designati cum capacitate alta sustinendi tensiones impulsus, nostri transformatores possunt tolerare surges electricos repentinos et overvoltages transientes, dum tolerantia eorum exceptionalis circuiti brevis operationem tuto garantiat in conditionibus fault, tutamen simul machinarum et systematum electricorum praebens.

Specificationes Technicae Principales

Tabula sequens detegit specificationes technicas claves producti, comprehensiva perfomantiam electricam, characteristica mechanicam, et parametra dimensionales ad referentiam claritativam pro selectione technica et sceneriis applicationis praebendam.

 

 

 

FAQ
Q: Num opus sit praesidia adhibere in transformatoribus terrae/terrae et quae sunt communia genera praesidiorum
A:

Specialis dispositiva protectionis configuranda sunt, quia eorum vitia ad circuiti systematis a terram conductionis deficere possunt, causantes damnum instrumentorum vel amplificantes ambitum delectricationis. Communes species protectionis includunt: ① Protectionem percurrentiae: visata ad brevi temporis percurrentiam in vitiis, cuius tempus actionis cum tempore tolerationis vitiis congruit (exempli gratia, toleratio 30 secundorum convenit ad tempus actionis 0-20 secundorum); ② Protectionem percurrentiae zero-sequentiae: observans percurrentiam zero-sequentiam anormalem et distinguens inter normalem inaequabilitatem percurrentiae et percurrentiam vitiis a terram; ③ Protectionem caloris: observans temperaturam olei pro specie immersa oleo et temperaturam spirearum pro specie sicca ut praeventur sit overheating damage; ④ Protectionem gas (solum pro specie immersa oleo): detectans quantitatem gas in oleo ut monstret interna disiectamenta vel vitiis overheating; ⑤ Protectionem supervoltantis: praeventur fracturam insulationis ab operando supervoltanti vel fulgur supervoltante per arrestatores parallelas. Hae protectiones cooperari debent cum protectione relativa systematis et exigentibus logica actionis standardis IEEE 32.

Q: Quae sunt differentiae inter focus operationis et maintenance cotidianae inter transformatores terrae vel aterram imbibitos oleo et siccos?
A:

Focus operis et maintenance variat propter differentias in methodis refrigerationis insulationis: ① Pro typo oleo-immerso, oportet attendere ad monitorium qualitatis olei (humiditas, dissipatio dielectrica), nivellum olei, et status operationis systematis refrigerationis (sicut initium et finis ventilatoris ONAF), facere regulariter analysis chromatographica olei, et investigare pericula discharge internae; ② Pro typo sicco, oportet attendere ad inspectionem appearance insulationis spirentium (utrum sint fissurae vel sordes), humiditatem ambientem (ut vitetur condensatio), et incrementum caloris, facere regulariter testes resistentiae insulationis, et augmentare frequentiam netandi praesertim in ambientibus humidis vel pulverulentis. Ambobus opus est regulariter verificare valorem impedimentum sequentiae nullae ut assequatur concordiam cum valore setting protectionis.

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Impactus Praejudicialis Bias Directi Currentis in Transformeribus ad Stationibus Energiae Renovabilis Proximis Electrodis Terrae UHVDC
    Impactus DC Bias in Transformeribus ad Stationes Energeticae Renovabiles Proximas Electrodis Terrae UHVDCCum electrum terrae systematis transmissionis Ultra-Alta-Voltura Directa (UHVDC) sit prope stationem energeticae renovabilis, currus reditus per terram fluens potest causare incrementum potentialis terrae circa aream electri. Hoc incrementum potentialis terrae ducit ad mutationem potentialis puncti neutri transformatorum proximorum, inducendo bias DC (vel offset DC) in eorum nucleis. Talis bi
    01/15/2026
  • HECI GCB for Generators – Cepus SF₆ Circuit Breaker
    1. Definitio et Functio1.1 Munus Interruptoris Circuiti GeneratorisInterruptor Circuitus Generatoris (GCB) est punctum disiunctionis controllabile situatum inter generator et transformator incrementalis, servans ut interficium inter generator et rete electricitatis. Principales eius functiones includunt isolationem defectuum lateris generatoris et facilitationem controlis operationis durante synchronizatione generatoris et connectione ad rete. Principium operativum GCB non differt significanter
    01/06/2026
  • Apparatus Distributionis Transformatorisque Experimentatio Inspectio et Conservatio
    1. Manutentio et Inspectio Transformatoris Aperi interruptorem circuitus bassae tensionis (LV) transformatoris in manu, remove fusum alimenti controlis, et pende signum “Noli Claudere” super manubrium commutationis. Aperi interruptorem circuitus altae tensionis (HV) transformatoris in manu, claudi commutatorem terrae, exsolvare totaliter transformatorem, claude armarium interruptoris HV, et pende signum “Noli Claudere” super manubrium commutationis. Pro manutentione transformatoris sicci: primo
    12/25/2025
  • Quomodo Resistentiam Isolationis Transformatorum Distributionis Probes
    In operibus practicis, resistentia insulationis transformatorum distributionis saepe bis metitur: resistentiam inter spiram alti voltaginis (HV) et spiram bassi voltaginis (LV) plus vasum transformatoris, et resistentiam inter spiram LV et spiram HV plus vasum transformatoris.Si ambae mensurationes valores acceptabiles praebent, indicat quod insulatio inter spiram HV, spiram LV, et vasum transformatoris est probata. Si una mensuratio deficiat, testes pairwise resistentiae insulationis inter omne
    12/25/2025
  • Principia Design pro Transformeribus Distributionis in Columna Fixis
    Principia Design Pro Distributionibus Transformerum in Polum Fixis(1) Principia Locorum et DispositionumPlataformae transformerum in polum fixarum debent collocari iuxta centrum oneris aut prope onera critica, secundum principium “parva capacitas, plura loca” ad facilitatem substitutionis et maintenance. Ad distributionem electricitatis domesticam, transformatores triphasici possunt instaurari iuxta necessitatem praesentem et projectiones futurorum incrementorum.(2) Selectio Capacitatis pro Tran
    12/25/2025
  • Solutio Controlis Stridoris Transformatorum pro Diversis Installationibus
    1. Mitigatio sonoris pro camera transformatoris independente in superficie terraeStrategia mitigationis:Primum, fac inspectionem et maintenance cum potestate interrupta, includens renovationem olei insulantis vetustatis, examinationem et consolidationem omnium fixorum, et mundationem pulvis a unitate.Deinde, reficere fundamentum transformatoris vel installare dispositiva isolationis vibrationis—ut gommae vel isolatores springalis—selecta secundum gravitatem vibrationis.Tandem, fortificare insula
    12/25/2025

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Instrumenta Libera Cognata
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum