• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


66-138 kV medialis insulatio directa coniunctio (robur aquae repellens)

  • 66-138 kV intermediate insulation, direct connection (reinforced waterproof type)

Attributa principalia

Marca Switchgear parts
Numerus Modeli 66-138 kV medialis insulatio directa coniunctio (robur aquae repellens)
Votum nominatum 138kV
Series YJJJI

Descriptiones productorum a fornitori

Descriptio

Nomen et Modello
Commissura praefabricata insulatoria integrata YJJJI
Commissura praefabricata directa integrata YJJTI

1. Definitio et classificatio producti
Commissura insulatoria intermedia: ad disjungendum electriciter metallica vestimenta, scuta terrae et scuta insulatoria, apta pro scenariis quibus requiritur segmentatum terrae
Conector directus intermedius: conservat continuitatem electricam inter metallicam vestimentam et stratum scuti, aptus pro continua coniunctione longarum distanciarum cabling
Ambae pertinent ad commissuras praefabricatas alta tensio, cum niveis tensionis a 66-138 kV. Utilizant componentes insulatoriae rubber praefabricatae integrales, plerumque ex silicone rubber importato, cum excellenti performance sigillandi et insulatoriae
2. Characteristicae technologiae aquae repellentis
Solutio interna obstructionis aquae: sicut materialis 578 # obstructionis aquae 3M, potest radiale sigillare humiditatem in corde et adhuc transire testa vivens per longum tempus sub pressione aquae 1 metrum
Structura multistrata aquae repellens: utendo fascia 2228 # aquae repellens ut stratum principale aquae repellens, suas characteristicae auto-melting possunt formare stratum aquae repellens forma testae, quod fuit verificatum per testa immersionis per longum tempus
Sigillatio termini contractionis frigidae: tertia generatio technologiae contractionis frigidae format sigillum adaptabile per lutum silicis rubri et pressionem contractionis frigidae, adaptans ad extrema ambientes
3. Requiritamenta performance
Performance electrica: resistentia insulatoria non debet esse minor quam 100m Ω ad temperaturam ambiente, et testa tolerantia voltage debet esse 1.5 vice rated voltage (pro 1 hora)
Characteristicae mechanicae: tensio trahendi externae vestimentae est ≥ 12MPa, et elongatio ad rumpere est ≥ 300%
Sigillatio: oportet sustinere pressionem aquae 0.6MPa pro 1 hora sine effluvium
4. Installatio et adaptabilitas ambientalis
Conditiones installationis: temperatura ambiente 5-35 ℃, humectas relativa ≤ 70%
Scenarii applicabiles: apta pro usu tam interno quam externo, altitudo<4000m, range temperatura -50 ℃~50 ℃
5. Advantage comparatis connectoribus traditionibus
Exempta maintenance, sigillatio vitalis, vitando periculum explosionis terminalis manicae ceramicae
Valorem parva partialis emissio, fortis resistencia pollutionis, apta pro ambientes altae pollutionisSpecificationes technicae

Nivelem Voltage (kV) 138 110 66
Maximum Operativum Voltage (kV) 145 126 72.5
Pondus (kg) ≈85 ≈85 ≈85
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum