• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


60-120MVA GSU IEE-Business Generator Step-Up Transformer pro fontes renovabiles (Transformer ad generationem)

  • 60-120MVA GSU Generator Step-Up Transformer for Renewable Energy(Transformer for generation)

Attributa principalia

Marca ROCKWILL
Numerus Modeli 60-120MVA GSU IEE-Business Generator Step-Up Transformer pro fontes renovabiles (Transformer ad generationem)
Frequenta nominata 50/60Hz
Series GSU

Descriptiones productorum a fornitori

Descriptio

Descriptio

Transformator Augendi Gradum (GSU) pro energiis renovabilibus est dispositivum specialis conversionis electricitatis constructum ad integrandum fontes energiarum renovabilium (sicut ventus, sol, aqua, et biomassa) in rete. Convertit electricitatem parvam tensionis generatam a generatoribus energiarum renovabilium (typice 0.4kV–35kV) in electricitatem magnam tensionis (110kV–500kV vel ultra), faciens efficientem transmissionem longinquam et assecurans compatibilitatem cum principali rete electrico. Quia nexus criticus inter systemata energiarum renovabilium et reticulum, directe afficit stabilitatem, efficientiam, et fiduciam traductionis energiae purae, supportans integrationem largam potentiarum viridium in reticula globalia energiarum.

  • 3-ph 60-120MVA, Ynd1, ONAN/ONAF

  • continens producta capacitate et gradu tensionis usque ad 360MVA/330KV.

Characteristica

  • Adaptabilitas ad Onus Fluctuantia: Optimum ad tractandum effluvium intermittens a renouabilibus (exempli gratia variationes velocitatis venti, mutationes irradiationis solaris), cum forti capacitate superonera ad accommodandum subita incrementa generationis energiae.

  • Parsimonia & Alta Efficientia: Utitur materialibus nucleorum altiperformantibus (exempli gratia alloy amorphous) et designis spirentium optimatis ad minimandum perditas sine onere et cum onere, augmentando efficientiam totalem conversionis energiae (saepe excedens 98%) ad maximandam utilisationem energiae purae.

  • Compliance Codicum Reticularum: Equipatus cum feature filtrationis harmonicae et regulationis tensionis ad satisfaciendum codices reticularum strictos (exempli gratia IEEE 1547, IEC 61400), reducendo distortionem harmonicam et assecurando stabilem integrationem reticularum sine turbatione qualitatis potestatis.

  • Resistentia Ambientalis & Meteorologica: Pro projectis renouabilibus externis (ventorum campus, parci solares), habet clausuras resistentes corrosioni, protectionem IP65-rated, et tolerantiam temperaturarum extremarum (-40°C ad 50°C), adaptans ad conditiones naturales duras.

  • Design Compactus & Modularis: Idoneus pro locis renouabilibus angustis (exempli gratia solares tectales, platformae ventorum maritimae) cum structura compacta; componentes modulares permittunt installationem facilem, manutenctionem, et scalabilitatem pro expansione futura capacitatis.

  • Capacitates Monitorandi Intelligentis: Integratus cum sensoribus IoT ad sequendum parametra real-time (temperatura, onus, status insulationis) et supportandam diagnosticam remota, congruens cum necessitatibus gestionis digitalis plantarum renouabilium modernarum.

FAQ
Q: Quae est capacitas transformatorum electricorum usque ad 345kV et quae sunt standardizatae capacitatis gradationes?
A:
Capacitas transformatoris fortem relationem ad nivum tensionis habet, et range capacitatis ac valores standard conformantur specificationibus generalibus internationalibus. Detalia sunt ut sequitur:
  • Range capacitatis per nivum tensionis: ① Alta Tensio (AT, 66kV - 220kV): 5MVA – 250MVA; ② Extra Alta Tensio (EAT, 220kV - 400kV): 250MVA – 600MVA+. Maiores capacitates solent per methodos refrixionis coactae (e.g., ONAF, OFAF) obtineri.
  • Valores standard capacitatis: Valores standard acceptati internationaliter includunt 30MVA, 45MVA, 60MVA, 90MVA, 100MVA, 120MVA, 150MVA, 200MVA, 250MVA, 315MVA, 400MVA, et 500MVA. Hi ratings late in designo et productione adoptantur.
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Impactus Praejudicialis Bias Directi Currentis in Transformeribus ad Stationibus Energiae Renovabilis Proximis Electrodis Terrae UHVDC
    Impactus DC Bias in Transformeribus ad Stationes Energeticae Renovabiles Proximas Electrodis Terrae UHVDCCum electrum terrae systematis transmissionis Ultra-Alta-Voltura Directa (UHVDC) sit prope stationem energeticae renovabilis, currus reditus per terram fluens potest causare incrementum potentialis terrae circa aream electri. Hoc incrementum potentialis terrae ducit ad mutationem potentialis puncti neutri transformatorum proximorum, inducendo bias DC (vel offset DC) in eorum nucleis. Talis bi
    01/15/2026
  • HECI GCB for Generators – Cepus SF₆ Circuit Breaker
    1. Definitio et Functio1.1 Munus Interruptoris Circuiti GeneratorisInterruptor Circuitus Generatoris (GCB) est punctum disiunctionis controllabile situatum inter generator et transformator incrementalis, servans ut interficium inter generator et rete electricitatis. Principales eius functiones includunt isolationem defectuum lateris generatoris et facilitationem controlis operationis durante synchronizatione generatoris et connectione ad rete. Principium operativum GCB non differt significanter
    01/06/2026
  • Apparatus Distributionis Transformatorisque Experimentatio Inspectio et Conservatio
    1. Manutentio et Inspectio Transformatoris Aperi interruptorem circuitus bassae tensionis (LV) transformatoris in manu, remove fusum alimenti controlis, et pende signum “Noli Claudere” super manubrium commutationis. Aperi interruptorem circuitus altae tensionis (HV) transformatoris in manu, claudi commutatorem terrae, exsolvare totaliter transformatorem, claude armarium interruptoris HV, et pende signum “Noli Claudere” super manubrium commutationis. Pro manutentione transformatoris sicci: primo
    12/25/2025
  • Quomodo Resistentiam Isolationis Transformatorum Distributionis Probes
    In operibus practicis, resistentia insulationis transformatorum distributionis saepe bis metitur: resistentiam inter spiram alti voltaginis (HV) et spiram bassi voltaginis (LV) plus vasum transformatoris, et resistentiam inter spiram LV et spiram HV plus vasum transformatoris.Si ambae mensurationes valores acceptabiles praebent, indicat quod insulatio inter spiram HV, spiram LV, et vasum transformatoris est probata. Si una mensuratio deficiat, testes pairwise resistentiae insulationis inter omne
    12/25/2025
  • Principia Design pro Transformeribus Distributionis in Columna Fixis
    Principia Design Pro Distributionibus Transformerum in Polum Fixis(1) Principia Locorum et DispositionumPlataformae transformerum in polum fixarum debent collocari iuxta centrum oneris aut prope onera critica, secundum principium “parva capacitas, plura loca” ad facilitatem substitutionis et maintenance. Ad distributionem electricitatis domesticam, transformatores triphasici possunt instaurari iuxta necessitatem praesentem et projectiones futurorum incrementorum.(2) Selectio Capacitatis pro Tran
    12/25/2025
  • Solutio Controlis Stridoris Transformatorum pro Diversis Installationibus
    1. Mitigatio sonoris pro camera transformatoris independente in superficie terraeStrategia mitigationis:Primum, fac inspectionem et maintenance cum potestate interrupta, includens renovationem olei insulantis vetustatis, examinationem et consolidationem omnium fixorum, et mundationem pulvis a unitate.Deinde, reficere fundamentum transformatoris vel installare dispositiva isolationis vibrationis—ut gommae vel isolatores springalis—selecta secundum gravitatem vibrationis.Tandem, fortificare insula
    12/25/2025

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Instrumenta Libera Cognata
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum