Serie HD2000 Conversor de Frecuencia de Ingeniería de Baja Tensión (Enfriado por Agua)

  • 400V/690V/1140V/1380V 160kW~2800k Low Voltage Engineered Frequency Converter
  • 400V/690V/1140V/1380V 160kW~2800k Low Voltage Engineered Frequency Converter

Attributa principalia

Marca RW Energy
Numerus Modeli Serie HD2000 Conversor de Frecuencia de Ingeniería de Baja Tensión (Enfriado por Agua)
Frequenta nominata 50/60Hz
Series HD2000

Descriptiones productorum a fornitori

Descriptio

Summatio

400V, 690V, 1140V, 1380V/160kW~2800kW, et potentia maxima machinae parallelae potest attingere 22400kW

Characteristica performance

Design fidei ingeniosus

  • Redundantia alta systematis controlis et systematis potestatis

  • Design dissipandi caloris per aquam, sonus parvus et melior dissipatio caloris

  • Conexio fibrae opticae, fortior vis resistendi perturbationibus

"Obstructa" design

  • Componentes modulares, omnis servitium frontale

  • Non requiritur instrumenta specialia, servitium simplex et commodum

  • Systema intelligentis diagnosi errorum pro celeri locatione

Design adplicabilis valde

  •  Adaptabilitas reticuli fortis, supportat input latum reticuli

  • Supportat transmissionem uniaxiale et multiaxiale

  • Equipatum cum serie productorum unitatum et armarii unitatum

  • Supportat tres methodos differentes rectificationis

  • Supportat varietas protocolorum communicationis et modulorum encoder

Control praestans

  • Adaptatus ad motus asynchronos et motus permanentis magnetis synchronous

  • Schemata rectificationis duobus et quattuor quadrantibus

  • Rectificatio, inversio parallelis et technologia commutationis currentis parallelis

  • Technologia commutationis automatica OLVC et CLVC in linea

  • Technologia controlis synchroni magistri et servi

  • Technologia controlis aequilibrationis oneris

Protocolla communicationis & software sagax

  • Supportat plura protocolla communicationis (Profibus DP, CANopen, Profinet IO, Modbus RTU, Modbus TCP, EtherCAT, EtherNet, ControlNet et DeviceNet)

  • Praebet instrumentum celeris debugging hopeInsight ad realisationem parametrarum setting online, monitoring status, recording intelligentis errorum et diagnosi errorum, etc

Parametri principes

project

Specifications and technical data

Basic rectification

Input voltage

4:380V~480V,6:500V~690V

Input frequency

(50Hz/60Hz)±6%

Output voltage

Input Voltage*1.32 (Full Load Condition)

Overload capacity

Relative base load current IH_DC allows 150% overload for 60s with a maximum current Imax_DC overload 5s, load cycle 300s

Efficiency

≥99%

Protection function

Overheating protection, soft rise protection, interlock protection, etc

Intelligent rectification

Input voltage

4:380V~480V,6:500V~690V

Input frequency

47~63Hz

Output voltage

Input Voltage*1.3 (Full Load Condition)

Overload capacity

Relative base load current IH_DC allows 150% overload for 60s with a maximum current Imax_DC overload 5s, load cycle 300s

Efficiency

≥98.5%

Protection function

Overheat protection, overcurrent protection, IGBT pass-through protection, etc

PWM rectification

Input voltage

4:380V~480V,6:500V~690V,9:1140V,A:1380V

Input frequency

47~63Hz

Output voltage

Input Voltage*1.5 (Rated Condition)

Overload capacity

Relative base load current IH_DC allows 150% overload for 60s with a maximum current Imax_DC overload 5s, load cycle 300s

Efficiency

≥98% (including LCL filter unit)

Factor

Adjustable (factory set to 1)

Protection function

Over-temperature protection, over-current protection, overload protection, IGBT pass-through protection, etc

Inverse

Rated input voltage

4:410Vdc~780Vdc,6:550Vdc~1100Vdc,9:1488Vdc~2200Vdc

A:1488Vdc~2200Vdc

Output voltage

0~Rectifier AC input voltage

Output frequency

0~500Hz

speed regulation range

V/F:1:50  OLVC:1:200  CLVC:1:1000

Steady speed accuracy

OLVC:0.2% ; CLVC:0.01%

Pulsating speed

OLVC:0.2%; CLVC:0.1%

Start torque

OLVC:150%(0.5Hz) ; CLVC:200%(0Hz)

Torque control

V/F: Not supported; OLVC: Support ; CLVC: Yes

Torque accuracy

OLVC:5% ; CLVC:5%

Torque response time

OLVC:5ms ; CLVC:5ms

RPM response time

OLVC:100ms; CLVC:100ms

Dynamic drop equivalent

OLVC:0.5%*s; CLVC:0.3%*s

environmental conditions

temperature

-15°C~+40°C is not degraded, and +40°C~+55°C is degraded

humidity

5%~95% non-condensation

elevation

≤ 4000m, 2000m~4000m reduced use

Mechanical data

Anti-vibration performance

Complies with IEC 60721-3-3:2002

Protection level

IP00 / IP20 / IP40

Safety level

Meets UL 508C-2004

Cooling method

Cold wind, cold water

Bibliotheca Documentorum Rerum
Restricted
Low Voltage Engineering Single-Drive/ Multi-Drive Variable Frequency System catalog
Catalogue
English
Consulting
Consulting
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 30000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 100000000
Locus Operis: 30000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 100000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: robot/Energia nova/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Impactus Praejudicialis Bias Directi Currentis in Transformeribus ad Stationibus Energiae Renovabilis Proximis Electrodis Terrae UHVDC
    Impactus DC Bias in Transformeribus ad Stationes Energeticae Renovabiles Proximas Electrodis Terrae UHVDCCum electrum terrae systematis transmissionis Ultra-Alta-Voltura Directa (UHVDC) sit prope stationem energeticae renovabilis, currus reditus per terram fluens potest causare incrementum potentialis terrae circa aream electri. Hoc incrementum potentialis terrae ducit ad mutationem potentialis puncti neutri transformatorum proximorum, inducendo bias DC (vel offset DC) in eorum nucleis. Talis bi
    01/15/2026
  • HECI GCB for Generators – Cepus SF₆ Circuit Breaker
    1. Definitio et Functio1.1 Munus Interruptoris Circuiti GeneratorisInterruptor Circuitus Generatoris (GCB) est punctum disiunctionis controllabile situatum inter generator et transformator incrementalis, servans ut interficium inter generator et rete electricitatis. Principales eius functiones includunt isolationem defectuum lateris generatoris et facilitationem controlis operationis durante synchronizatione generatoris et connectione ad rete. Principium operativum GCB non differt significanter
    01/06/2026
  • Apparatus Distributionis Transformatorisque Experimentatio Inspectio et Conservatio
    1. Manutentio et Inspectio Transformatoris Aperi interruptorem circuitus bassae tensionis (LV) transformatoris in manu, remove fusum alimenti controlis, et pende signum “Noli Claudere” super manubrium commutationis. Aperi interruptorem circuitus altae tensionis (HV) transformatoris in manu, claudi commutatorem terrae, exsolvare totaliter transformatorem, claude armarium interruptoris HV, et pende signum “Noli Claudere” super manubrium commutationis. Pro manutentione transformatoris sicci: primo
    12/25/2025
  • Quomodo Resistentiam Isolationis Transformatorum Distributionis Probes
    In operibus practicis, resistentia insulationis transformatorum distributionis saepe bis metitur: resistentiam inter spiram alti voltaginis (HV) et spiram bassi voltaginis (LV) plus vasum transformatoris, et resistentiam inter spiram LV et spiram HV plus vasum transformatoris.Si ambae mensurationes valores acceptabiles praebent, indicat quod insulatio inter spiram HV, spiram LV, et vasum transformatoris est probata. Si una mensuratio deficiat, testes pairwise resistentiae insulationis inter omne
    12/25/2025
  • Principia Design pro Transformeribus Distributionis in Columna Fixis
    Principia Design Pro Distributionibus Transformerum in Polum Fixis(1) Principia Locorum et DispositionumPlataformae transformerum in polum fixarum debent collocari iuxta centrum oneris aut prope onera critica, secundum principium “parva capacitas, plura loca” ad facilitatem substitutionis et maintenance. Ad distributionem electricitatis domesticam, transformatores triphasici possunt instaurari iuxta necessitatem praesentem et projectiones futurorum incrementorum.(2) Selectio Capacitatis pro Tran
    12/25/2025
  • Solutio Controlis Stridoris Transformatorum pro Diversis Installationibus
    1. Mitigatio sonoris pro camera transformatoris independente in superficie terraeStrategia mitigationis:Primum, fac inspectionem et maintenance cum potestate interrupta, includens renovationem olei insulantis vetustatis, examinationem et consolidationem omnium fixorum, et mundationem pulvis a unitate.Deinde, reficere fundamentum transformatoris vel installare dispositiva isolationis vibrationis—ut gommae vel isolatores springalis—selecta secundum gravitatem vibrationis.Tandem, fortificare insula
    12/25/2025

Solutiones Relatae

  • Systemata automationis distributionis solutio
    Quae sunt difficultates in operatione et maintenance lineae aereae?Difficultas una:Lineae distributionis aerea latam extensionem habent, terrain complicatam, multas ramificationes radiantis et supply power distributum, quod "multa culpa lineae et difficultas in reperiendo errore" producit.Difficultas duo:Reperire manu errorem tempus consumit et laboriosum est. Simul, currentem, tensionem et statum commutationis lineae non potest comprehendere in tempore reali, propter defectum mediorum technicor
    04/22/2025
  • Solutio Integratum Monitorationis Intelligentis Potentiae et Administrationis Efficienciae Energeticae
    Visio generalisHoc opus ad praebendum systema intelligentis monitorii electricitatis (Systema Managementis Electricitatis, PMS) centrum ponit in optimisatione termino ad terminum ressource electricitatis. Per constitutionem framework managementi clausi "monitoring-analysis-decision-execution," iuvat societates a simpliciter "electricitatem utendo" ad intelligenter "electricitatem administrando" transire, tandem ad fines usus energiae securi, efficientis, paucicarbonis et oeconomici perveniens.Po
    09/28/2025
  • Una Nova Solutio Modularis pro Systematibus Generationis Energiae Photovoltaicae et Storaginis
    1. Introductio et Background Investigativus1.1 Status Quodammodo Solaris IndustriaeUt una ex copiosissimis fontibus renovabilium, solis energiae developmentum et usus iam centrum factus est globali transitioni energeticae. Recentibus annis, impulsu politarum mundi, industria photovoltaica (PV) prodigiosa progressione gavisa est. Statistica indicant quod PV industria Sinica vidiit incrementum 168-plex durante "Duodecimo Quinquennio". Ad finem 2015, installata PV capacitas excessit 40,000 MW, tres
    09/28/2025
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum