• 5kW Single Three-phase Integrated Small Diesel Generator Set
  • 5kW Single Three-phase Integrated Small Diesel Generator Set
  • 5kW Single Three-phase Integrated Small Diesel Generator Set
  • 5kW Single Three-phase Integrated Small Diesel Generator Set
5kW Single Three-phase Integrated Small Diesel Generator Set
$5000.00
Model
DMDS6500LE
Basic info
Brand Wone
Model NO. 5kW Single Three-phase Integrated Small Diesel Generator Set
Phases Single /Three
Engine Max Output Power 6.5/3600 kW/rpm
Generator Rated Power 5.0 kW
Generator Rated Voltage 230V、230/400V
Generator Capacity 12.5L
Series Small diesel generator set
Product Detail

Description:

  • Large muffler, dynamic balance shaft, special design of low-noise unit, shell and frame with shock absorption function.

  • Large capacity fuel tank to ensure long-term continuous work.

  • Non-fuse circuit breaker provides overload protection, capacitive voltage regulator to ensure stable voltage output.

  • Durable four-wheel dragging base structure, easy to move.

Parameter:

image.png

Feature:

Single - cylinder air - cooled engine - compact structure

It is a four - stroke, direct - injection, air - cooled engine with well - designed transmission mechanism. It features light weight, small volume, and low failure rate. The high - precision fuel injection pump enables more complete combustion of fuel and saves fuel.

企业微信截图_1734333634346.png

Arbitrary switching between single - phase and three - phase — equal power output

  • The single - phase and three - phase have an equal power output of 5 kilowatts, and the dual - voltage can be switched with one key, which is convenient and fast.

  • When switched to 230V: single - phase power generation is 5KW.

  • When switched to 400V: three - phase power generation is 5KW.

企业微信截图_17343338181766.png

The open - shelf structure - convenient for maintenance

  • It uses high - quality metal pipes and has a shelf - like design. It is integrally welded, with a high safety factor and good heat dissipation performance.

  • It is convenient for maintenance and suitable for various engineering construction applications and outdoor transportation.

OTC automatic welding

  • The frame is more solid, and the joints are not easy to break.

  • It is safer and more reassuring.

企业微信截图_17343339424276.png

Standard - equipped mobile fire - wheels — convenient for movement

  • It is convenient for movement in outdoor construction. The wheels are made of nylon, which is wear - resistant and has a long service life.Contact customer service to customize brake - equipped universal wheels according to your own needs. The brake - equipped universal caster wheels can be temporarily fixed when in use and converted to a rotation mode when pushed.

企业微信截图_17343340651622.png

The all - copper - wire damping motor - high reliability

  • The damping motor has good waveform, small distortion, strong overload capacity and high reliability. Equipped with an AVR automatic voltage regulator, it stabilizes the output voltage of the generator and automatically changes the excitation current size.

企业微信截图_17343341581777.png


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
What are the typical connection methods for 35kV distribution lines?
What are the typical connection methods for 35kV distribution lines?
Typical Wiring Diagram of 35kV Line Radial π ConnectionWhen a 35kV line adopts a radial power grid structure, a single - side power supply or a double - side power supply radial type can be used according to the situation of the power supply points, and a loop - out interval is reserved at the end of the line.Typical Wiring Diagram of 35kV Line Radial T - ConnectionFor double - radial lines, it is advisable to select a double - side power supply. When the power supply points do not meet the r
Leon
07/18/2025
Why are the ground fault point and the accident point not at the same location?
Why are the ground fault point and the accident point not at the same location?
Fault Transfer VoltageIn low - voltage distribution systems, there is a type of personal electric shock accident where the accident occurrence point and the system fault point are not at the same location. This kind of accident occurs because after a ground fault happens elsewhere, the generated fault voltage is conducted to the metal casings of other equipment through the PE wire or PEN wire. When the fault voltage on the metal casing of the equipment is higher than the human - body safe voltag
Leon
07/18/2025
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!