| Brand | Wone Store |
| Numero ng Modelo | 3-phase Shell type Magnetically controlled vacuum circuit breaker Tres na phase na tipo ng shell na magneticamente kontroladong vacuum circuit breaker |
| Tensyon na Naka-ugali | 12kV |
| Rated Current | 2000A |
| bilang ng mga pole | 3P |
| Rated short-circuit breaking current | 31.5kA |
| Serye | MS5 |
Ang serye ng MS5-12-630/20-XX na mga circuit breaker ay mga indoor switchgear na batay sa mekanismo ng aktuator na semi-hard magnetic material. Ito ay ginagamit sa three-phase AC power systems na may rated voltage ng 12KV at frequency ng 50-60Hz, bilang isang protective at control device. Ito ay partikular na angkop para sa mabibigat na operasyon sa rated current o maraming pag-break ng short-circuit currents. Ang serye ng mga circuit breaker na ito ay kasama ang circuit breaker at ang drive module.
Ang estruktura ng circuit breaker
Bawat phase ay may isang aktuator mechanism, na inilalapat nang perpendicularly at axially sa vacuum interrupter. Ang tatlong excitation coils ay konektado sa parallel. Ang tatlong-phase aktuator
mechanisms ay nagkakamit ng synchronous action sa pamamagitan ng synchronous shaft at samantalang naglilikha ng auxiliary switch position signal output.
Ang vacuum interrupter ay gumagamit ng external bellows, at ang bellows ay gawa sa stainless steel lamination welding process. Ang contact opening distance ay 8mm at ang overtravel ay 2mm. Ang contacts ay disenyo batay sa prinsipyong longitudinal magnetic field arc extinguishing.
Contact pressure spring sa insulating rod upang matiyak ang maasahan na contact sa pagitan ng moving at static contacts ng VI at na ang related actions ay sumasang-ayon sa operational characteristic
requirements.
Ang insulating frame ay gawa ng SMC, na nakapaligid sa upper at lower terminals, operating insulating rods, flexible connections, vacuum interrupters at iba pang components, na gumagampan ng tungkulin ng insulation at support.
Paggamit
Suitable para sa air insulated switchgear.
Teknolohiya parameters
No. |
Item |
Unit |
MS5-07 |
MS5-08 |
MS5-09 |
MS5-10 |
1 |
Rated voltage |
kV |
12 |
12 |
12 |
12 |
2 |
Rated current |
A |
1250 |
1250 |
1600 |
1600 |
3 |
Rated power frequency withstand voltage |
kV |
42 |
42 |
42 |
42 |
4 |
Rated impulse withstand voltage |
kV |
85 |
85 |
85 |
85 |
5 |
Rated short circuit breaking current |
kA |
25 |
31.5 |
25 |
31.5 |
6 |
Rated peak withstand current |
kA |
63 |
80 |
63 |
80 |
7 |
Rated short-circuit withstand current |
kA |
25 |
31.5 |
25 |
31.5 |
8 |
Duration of short circuit |
s |
4 |
4 |
4 |
4 |
9 |
Rated frequency |
Hz |
50 |
50 |
50 |
50 |
10 |
Phase center distance |
mm |
210 |
210 |
210 |
210 |
11 |
Contact distance |
mm |
8±0.5 |
8±0.5 |
8±0.5 |
8±0.5 |
12 |
Over travel |
mm |
2±0.5 |
2±0.5 |
2±0.5 |
2±0.5 |
13 |
Rated operation cycle |
- |
O-0.3s-CO-15s-CO |
|||
14 |
Inherent closing time(don’t include DM time) |
ms |
< 25 |
< 25 |
< 25 |
< 25 |
15 |
Different time of closing operation |
ms |
≤2 |
≤2 |
≤2 |
≤2 |
16 |
Bouncing time |
ms |
≤2 |
≤2 |
≤2 |
≤2 |
17 |
Inherent opening time(don’t include DM time) |
ms |
5±0.5 |
5±0.5 |
5±0.5 |
5±0.5 |
18 |
Different time of opening operation |
ms |
≤2 |
≤2 |
≤2 |
≤2 |
19 |
Mechanical operations (CO-cycles) |
Times |
50000 |
50000 |
50000 |
50000 |
20 |
Rated short-circuit-breaking current time |
Times |
50 |
50 |
50 |
50 |
21 |
Number of auxiliary switches |
pcs |
6NO+6NC |
|||
22 |
Weight |
kg |
52 |
52 |
52 |
52 |
Sukat