• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Transformātor Terrestris Immersus in Oleo 33kv

  • 22kV 30kV 33kV 66kV Three phase Oil Immersed Grounding /Earthing Transformer Manufacturer

Attributa principalia

Marca ROCKWILL
Numerus Modeli Transformātor Terrestris Immersus in Oleo 33kv
Votum nominatum 33kV
Numerus phaseorum Three-phase
amplitudo frequentiae 50/60Hz
Series JDS

Descriptiones productorum a fornitori

Descriptio

Productus Intuitus

Rockwill specializatur in designo et fabrica transformatorum olei immersorum ad terram 33kV, ingeniose constructis pro protectione terrae fideliter in systematibus electricitatis. Nostri producta complentur cum normis internationalibus IEC et IEEE, garantientes operationem stabilam et securam reticulorum electricorum.

Specificationes Principales

Characteristica Producti

Nucleus Praestans

Nucleus transformatoris constat ex lamellis silicis ferri orientati frigore laminati altissimae qualitatis cum iuncturis diagonalibus plenis 45°. Ferreum iugum est firmatum cum perboltis, et columnae nucleorum sunt ligatae cum taenia fibrae vitreae. Superficies nuclei est obducta adhesivo resinae silicis pro protectione ab umiditate et reductione soni.

Involutio Superior

Involutions sunt constructae ex conductoribus cuprei altissimae qualitatis in structura cylindrica segmentata ad augendam insulationem inter stratos. Technologia siccativa vacui applicatur ad garantiam excellentis performance electricae, fortitudinis mechanicae maxima, et minimae dismissionis partialis.

Insulatio et Refrigeratio Progressiva

Transformator olei immersus ad terram habet tankam perfecte clausam cum finibus corrugatis pro dissipatione caloris efficienti, eliminando necessitatem tankae servationis olei. Tankae olei sunt clausae cum stipulis rubberis resistens oleo ad praeventionem contactus cum aere, conservantes qualitatem olei insulantis et extendentes longevitatem transformatoris. Pedem compactum, aspectum pulchrum, et designum sine maintenance sunt beneficia principalia.

Dispositiva Protectionis Completiora

Aequippatus cum valvulis solutorum pressionis, relais gas, et gaugis nivei olei pro monitoringu conditionis olei in tempore reali. Dispositiva controlis temperature supportant transmissionem remotam, permittentes supervisionem commodam temperaturae operantis transformatoris.

Parametri Technici

  • Tipo Transformatoris: Olei Immersi

  • Gruppi Connectionis: ZN (Zigzag)

  • Voltage Ratum: Usque ad 36kV

  • Currentus Ratus: Usque ad 3000A

  • Duratio Brevi Temporis: 10s / 30s / 60s vel customizatum

  • Methodus Refrigerationis: ONAN, ONAF, AN, AF

  • Installation: Intra / Extra

  • Amplitudo Temperaturarum Ambientalium: -40°C ad +40°C

  • Compliance Standardis: IEC 60076-6, IEC 60076-1, IEEE

  • Optiones Armarii: Armarium transformatoris cum ratingis IP customizabilibus, optionale CT, VT, et commutatorum isolationis

Notae

  • Currentus brevis temporis neutralis I0 = IG

  • Impedentia sequentiae zero neutralis Z0 = Impedentia phase / 3

  • ±5% off-load tap changer

  • Confirmare valorem Z0 ante productionem si non self-limiting

  • Tolerantia Z0 ≤ 10%

Rockwill 33kV Oil Immersed Grounding Transformers combinant technologiam progressivam et control strictum qualitatis ad offerendum solutiones terrae fidelas pro reticulis electricitatis universali. Pro inquiriis et customizationibus, sodes contacter nos.

FAQ
Q: Quomodo functio Zig-Zag coniunctio in tuo transformatore terrae 33kV operatur
A: Dispositio spira Zig-Zag (ZN) praebet viam impedimenti parvi pro currentibus defectus terrae dum prohibet currentes oneris normalis. In defectu creat fluxus magneticos oppositos ut currentem ad gradus tuto (24.8A continuo/800A per 20s) contineat simul stabilitatem systematis servans et damnum super-voltantis prohibens. Impedimentum eius sequentiae nullae (Z₀) accurate intra tolerantiam ≤10% regitur ut fidelem limitationem currentis defectus assecuraret.
Q: Quomodo tractari possint extremae conditiones (alta tempestatem, bassa tempestatem, alta altitudinem) pro transformatoribus exterioribus earthing/grounding?
A:

Extremae conditiones ambientes postulant designatum incrementum, cum specificis mensuris sicut sequitur: ① In alto calore (sicut in desertis): pro oleo-immersis, methodus refrigerationis ONAF/OFAF cogitata est ad meliorem dissipationem caloris; pro siccis, materialia insulatoria resistens altis thermis (gradus ≥ F) sunt usitata, et ductus aeris additi sunt; ② In frigido (sicut in regionibus gelidis): pro oleo-immersis, oleum insulatorium cum basso puncto congelationis (punctum congelationis ≤ -45℃) est electum, et dispositiva calefactionis configurata sunt; pro siccis, tegimenta insulatoria adduntur ut condensationem evitent; ③ In alta altitudine (altitudo > 1000m): fortitudo insulationis decrescit cum altitudine crescente, ergo margo insulationis meliorandus est (sicut 20% melioratio fortitudinis insulationis ad 2000m); pro oleo-immersis, limen monitorii nivellae olearum accommodari debet ad adaptandum mutationes pressionis; systema refrigerationis fanorum velocitatem optimizare debet ut diminutionem efficacitatis dissipationis caloris aeris compenset.

Q: Quae sunt characteristicae "no-load loss" et "load loss" transformatorum earthing/grounding et num significantem impactum habeant in costibus operativis
A:

Characteristica eius amissoria valde ad characteristica operativa pertinent: ① Amisit sine onere refertur ad amissum ferri (amissum hysteresis et turbinis nucleus) in usu normali. Propter statum sine onere/leve onus diuturnum, est amissio operativa principale; ② Amisit sub onere refertur ad amissum cupri (amissum resistentiae involucrum) in casibus, quod tantum generatur in casibus brevibus et habet proportionem valde parvam. Impactus super costas operativas oportet secundum scenariorum dividi: In rete distributionis basso voltu et medio voltu (transformatores terrae operantur diu), impactus sine onere manifestus est, et in electione formae cum minore amissione sine onere (sicut efficacia energiae nivis primi standardis nationis) debent praeferri; in systematibus alto voltu/extra alto voltu (transformatores terrae operantur tempore breve in casibus), proportio amissionis sine onere parva est, et praestantia tolerantiae casuum potest prioriter considerari. In toto, amissio annua multo minor est quam in transformatoribus potentiae ordinariis, et costa operativa relativiter parva est

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Impactus Praejudicialis Bias Directi Currentis in Transformeribus ad Stationibus Energiae Renovabilis Proximis Electrodis Terrae UHVDC
    Impactus DC Bias in Transformeribus ad Stationes Energeticae Renovabiles Proximas Electrodis Terrae UHVDCCum electrum terrae systematis transmissionis Ultra-Alta-Voltura Directa (UHVDC) sit prope stationem energeticae renovabilis, currus reditus per terram fluens potest causare incrementum potentialis terrae circa aream electri. Hoc incrementum potentialis terrae ducit ad mutationem potentialis puncti neutri transformatorum proximorum, inducendo bias DC (vel offset DC) in eorum nucleis. Talis bi
    01/15/2026
  • HECI GCB for Generators – Cepus SF₆ Circuit Breaker
    1. Definitio et Functio1.1 Munus Interruptoris Circuiti GeneratorisInterruptor Circuitus Generatoris (GCB) est punctum disiunctionis controllabile situatum inter generator et transformator incrementalis, servans ut interficium inter generator et rete electricitatis. Principales eius functiones includunt isolationem defectuum lateris generatoris et facilitationem controlis operationis durante synchronizatione generatoris et connectione ad rete. Principium operativum GCB non differt significanter
    01/06/2026
  • Apparatus Distributionis Transformatorisque Experimentatio Inspectio et Conservatio
    1. Manutentio et Inspectio Transformatoris Aperi interruptorem circuitus bassae tensionis (LV) transformatoris in manu, remove fusum alimenti controlis, et pende signum “Noli Claudere” super manubrium commutationis. Aperi interruptorem circuitus altae tensionis (HV) transformatoris in manu, claudi commutatorem terrae, exsolvare totaliter transformatorem, claude armarium interruptoris HV, et pende signum “Noli Claudere” super manubrium commutationis. Pro manutentione transformatoris sicci: primo
    12/25/2025
  • Quomodo Resistentiam Isolationis Transformatorum Distributionis Probes
    In operibus practicis, resistentia insulationis transformatorum distributionis saepe bis metitur: resistentiam inter spiram alti voltaginis (HV) et spiram bassi voltaginis (LV) plus vasum transformatoris, et resistentiam inter spiram LV et spiram HV plus vasum transformatoris.Si ambae mensurationes valores acceptabiles praebent, indicat quod insulatio inter spiram HV, spiram LV, et vasum transformatoris est probata. Si una mensuratio deficiat, testes pairwise resistentiae insulationis inter omne
    12/25/2025
  • Principia Design pro Transformeribus Distributionis in Columna Fixis
    Principia Design Pro Distributionibus Transformerum in Polum Fixis(1) Principia Locorum et DispositionumPlataformae transformerum in polum fixarum debent collocari iuxta centrum oneris aut prope onera critica, secundum principium “parva capacitas, plura loca” ad facilitatem substitutionis et maintenance. Ad distributionem electricitatis domesticam, transformatores triphasici possunt instaurari iuxta necessitatem praesentem et projectiones futurorum incrementorum.(2) Selectio Capacitatis pro Tran
    12/25/2025
  • Solutio Controlis Stridoris Transformatorum pro Diversis Installationibus
    1. Mitigatio sonoris pro camera transformatoris independente in superficie terraeStrategia mitigationis:Primum, fac inspectionem et maintenance cum potestate interrupta, includens renovationem olei insulantis vetustatis, examinationem et consolidationem omnium fixorum, et mundationem pulvis a unitate.Deinde, reficere fundamentum transformatoris vel installare dispositiva isolationis vibrationis—ut gommae vel isolatores springalis—selecta secundum gravitatem vibrationis.Tandem, fortificare insula
    12/25/2025

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Instrumenta Libera Cognata
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum