• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


6-35KV 33KV oleum immersa neutra terra connectio ad transformatorium (terra transformatorium)

  • 15kV 20kV 22kV 30kV 33kV 35kV oil-immersed neutral grounding resistance to transformer (earthing transfoemer)
  • 15kV 20kV 22kV 30kV 33kV 35kV oil-immersed neutral grounding resistance to transformer (earthing transfoemer)

Attributa principalia

Marca ROCKWILL
Numerus Modeli 6-35KV 33KV oleum immersa neutra terra connectio ad transformatorium (terra transformatorium)
Votum nominatum 33kV
Frequenta nominata 50/60Hz
Capacitas nominata 800kVA
Series JDS

Descriptiones productorum a fornitori

Descriptio

Introductio Producti

Transformatores nostrae oleo immersi ad terram connectentes, qui etiam transformatores earthing nominantur, pro rete medio-voltivo (6-35kV, inclusis 33kV) sunt compositi. Per technologiam refrigerationis olei, calorem secure dissipant. Connexio puncti neutralis cum resistentia ad terram creata, hii transformatores celeriter defectus terre detectant et limitant. Optimi ad fidem retis augmentandam, praebent tutelam robustam contra defectus electricos, certificantes supplymentum stabile potentiae pro usibus industrialibus et commercialibus.

Conditiones Operationis

  • Altitudo: ≤1,000 metrorum

Temperatura Ambientalis:

  • Maxima temperatura ambientalis: +40°C

  • Maxima temperatura media diurna: +30°C

  • Maxima temperatura media annua: +20°C

  • Minima temperatura exteri: -25°C

Advantagia Performance

  • Energeticum-Efficiens & Eco-Friendly: Designus parvo amissus, parvo sonitus, et alta efficiencia reducit consumtionem energiae et impactionem environmentalis.

  • Totaliter Clausus & Sine Maintenance: Non requiritur tankus storage olei. Designus tankus corrugatus automaticiter accommodat mutationes voluminis olei, eliminans pericula defluxus.

  • Vita Extensa: Structura clausa separat oleum ab aere, retardando degradatio et senectus insulationis. Reducit costus maintenance et extendit vitam operationalem.

Specificationes Technicae Principales

Tabula sequens detegit key technical specifications producti, copiosissime operando performance electrica, characteristica mechanicalia, et parametri dimensionales, ut referentiam clarificet pro selectione technica et scenariis applicationis.

 

FAQ
Q: Quae sunt praescripta specialia ad transformatores earthing/grounding, qui in navi vel platformis maritimis utuntur?
A:

Caracteristicae maris uti salis nebulam humiditatem vibrationem spatiumque limitatum exigunt ut transformatores earthing/grounding ad praescripta designandi specialia respondant: ① Protectio insulationis: Utere materialibus insulantibus resistentibus contra salis nebulam et fungum (uti cast resin resistentem salis nebulam) et superfaciem winding tegere cum coating anti-corrosionis; ② Design structurae: Adopta structuram modularem compactam uti spatio angusto navium/platformarum accommodet; dry-type (sine oleo) preferatur ut olei effusio polluantem marinam ambiantem evitetur; ③ Resistentia vibrationis: Reforces fixationem winding et clamping core ut requisitis mechanicis fluctus et vibrationis navi (vibration grade ≥ IEC 60076-5 Class 3) satisfaciat; ④ Tensio et frequentia: Necesse est uti tensio specifica navali (uti 6.6kV) et frequentia (uti 60Hz) adaptentur, et auxiliaris winding necesse habet uti demandae electricitatis stationis potenti navali (uti 440V/220V) satisfaciat; ⑤ Modus refrigerationis: Adopta aeris naturalis refrigerationem (KNAN) uti casus fan failure operationem affectantis evitetur et uti ambienti cabinarum clausarum accommodet.

Q: Quae parametri debent in primis spectari, cum transformator terrestris vel de terra substituendus sit, ut compatibilitas cum systemate pristino conservetur
A:

Sex corem parametrorum oportet unum et unum persequi in substitutione, ut compatibilitatis errores vitentur: ① Systematis tensio linealis: Eadem esse debet cum originali (exempli gratia, gradus 110kV pro originali 110kV); ② Impedimentum zero-sequence: Deviatio a valore originali non debet superare ≤ ±10%, ut certetur quod non opus sit ad iustitiam protectionis mutare; ③ Capacitas brevis temporis et tempus tolerationis defectus: Non debet esse inferior gradu originali (exempli gratia, si originale est 30 secundorum/5MVA, novum productum oportet hanc vel meliorem rationem complere); ④ Structura spira: Eadem esse debet cum genere originali (exempli gratia, si originale est forma zigzag, non potest substitui forma wye-delta) ut perfomantia terrae non mutetur; ⑤ Methodus insolationis et refrigerationis: Oportet adaptari scenariolo installationis originali (exempli gratia, si originale est oleo-immersum extra, non potest substitui secco intra); ⑥ Specificationes spira auxiliaris (si adsunt): Gradus tensionis et capacitas oportet convenire cum originali (exempli gratia, si originale est 400V/200kVA, novum productum oportet idem esse) ut certetur de regulari alimentatione auxiliari substationis.

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Impactus Praejudicialis Bias Directi Currentis in Transformeribus ad Stationibus Energiae Renovabilis Proximis Electrodis Terrae UHVDC
    Impactus DC Bias in Transformeribus ad Stationes Energeticae Renovabiles Proximas Electrodis Terrae UHVDCCum electrum terrae systematis transmissionis Ultra-Alta-Voltura Directa (UHVDC) sit prope stationem energeticae renovabilis, currus reditus per terram fluens potest causare incrementum potentialis terrae circa aream electri. Hoc incrementum potentialis terrae ducit ad mutationem potentialis puncti neutri transformatorum proximorum, inducendo bias DC (vel offset DC) in eorum nucleis. Talis bi
    01/15/2026
  • HECI GCB for Generators – Cepus SF₆ Circuit Breaker
    1. Definitio et Functio1.1 Munus Interruptoris Circuiti GeneratorisInterruptor Circuitus Generatoris (GCB) est punctum disiunctionis controllabile situatum inter generator et transformator incrementalis, servans ut interficium inter generator et rete electricitatis. Principales eius functiones includunt isolationem defectuum lateris generatoris et facilitationem controlis operationis durante synchronizatione generatoris et connectione ad rete. Principium operativum GCB non differt significanter
    01/06/2026
  • Apparatus Distributionis Transformatorisque Experimentatio Inspectio et Conservatio
    1. Manutentio et Inspectio Transformatoris Aperi interruptorem circuitus bassae tensionis (LV) transformatoris in manu, remove fusum alimenti controlis, et pende signum “Noli Claudere” super manubrium commutationis. Aperi interruptorem circuitus altae tensionis (HV) transformatoris in manu, claudi commutatorem terrae, exsolvare totaliter transformatorem, claude armarium interruptoris HV, et pende signum “Noli Claudere” super manubrium commutationis. Pro manutentione transformatoris sicci: primo
    12/25/2025
  • Quomodo Resistentiam Isolationis Transformatorum Distributionis Probes
    In operibus practicis, resistentia insulationis transformatorum distributionis saepe bis metitur: resistentiam inter spiram alti voltaginis (HV) et spiram bassi voltaginis (LV) plus vasum transformatoris, et resistentiam inter spiram LV et spiram HV plus vasum transformatoris.Si ambae mensurationes valores acceptabiles praebent, indicat quod insulatio inter spiram HV, spiram LV, et vasum transformatoris est probata. Si una mensuratio deficiat, testes pairwise resistentiae insulationis inter omne
    12/25/2025
  • Principia Design pro Transformeribus Distributionis in Columna Fixis
    Principia Design Pro Distributionibus Transformerum in Polum Fixis(1) Principia Locorum et DispositionumPlataformae transformerum in polum fixarum debent collocari iuxta centrum oneris aut prope onera critica, secundum principium “parva capacitas, plura loca” ad facilitatem substitutionis et maintenance. Ad distributionem electricitatis domesticam, transformatores triphasici possunt instaurari iuxta necessitatem praesentem et projectiones futurorum incrementorum.(2) Selectio Capacitatis pro Tran
    12/25/2025
  • Solutio Controlis Stridoris Transformatorum pro Diversis Installationibus
    1. Mitigatio sonoris pro camera transformatoris independente in superficie terraeStrategia mitigationis:Primum, fac inspectionem et maintenance cum potestate interrupta, includens renovationem olei insulantis vetustatis, examinationem et consolidationem omnium fixorum, et mundationem pulvis a unitate.Deinde, reficere fundamentum transformatoris vel installare dispositiva isolationis vibrationis—ut gommae vel isolatores springalis—selecta secundum gravitatem vibrationis.Tandem, fortificare insula
    12/25/2025

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Instrumenta Libera Cognata
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum