Reclosor automatis circuituum vacuum exterioris mediae tensionis 15kV/1250A

  • 12kV 13.2kV 13.8kV 14.5kV 15kV MV outdoor Three phase Smart recloser/reclosure Source Manufacturer

Attributa principalia

Marca ROCKWILL
Numerus Modeli Reclosor automatis circuituum vacuum exterioris mediae tensionis 15kV/1250A
Votum nominatum 15kV
currus electricus nominatus 1250A
currentis rumpendi nominale in circuitu commutato 25kA
Tensio sustentans frequentia industriale 36kV/min
Voltage tolerabile impulsum fulminis nominale 110kV
Manuale clausura Yes
claustra mechanicum
Series RCW

Descriptiones productorum a fornitori

Descriptio

Describtiō :

Sēriēs RCW automātiski circuit reclosers possunt adhiberi in lineīs distribūtiōnis super capitibus tamquam in applicationibus substationum distribūtiōnis pro omnibus classibus voltaginum ab 11kV usque ad 38kV in systemate electricitatis 50/60Hz. Et currentus eius nominālis potest attingere 1250A. Sēriēs RCW reclosers integrat functiones controlis, protectionis, mensurandī, communicationis, detectionis fault, on-line monitoring clausūrum aut apertūrum. Sēriēs RCW vacuum recloser prae ceteris combinatur cum integratione termināle, current transformer, permanent magnetic actuator et recloser controller.

Characteristicae :

  • Gradus optionales disponibiles in ambitu currentus nominālis.

  • Cum protectione relē et logica pro selectione usoris.

  • Cum protocolis communicationis et portis I/O pro electione usoris.

  • Software PC pro testationem, setup, programmationem, updates controlleris.

Parametri

image.png

image.png


Requisita ambientalia :

image.png

Demonstratio producti :

不代手合正方形硅橡胶永磁.png

带手合正方形 硅橡胶永磁带手合.png

Quid est extinguendi arcuum vacuum defectus foras vacuum recloser et solutio eius?

Defectus Camerae Extinguendi Arcuum Vacuum :

  • Vacuum Level Decreased: Hoc est problema communiter in camerae extinguendi arcuum vacuum. Camera huiusmodi dependet de ambientes vacuum altissimo ad extinguendum arcus. Si level vacuum diminuitur, performance insulationis et facultas extinguendi arcus significanter deteriorantur. Causae diminutionis vacuum includunt sealing malam, sicut materiale sealing vetustum vel damnum, vel parvulas fugas presentes in processu manufacturae. Cum level vacuum declinet ad certum punctum, incomplete extinguendo arcus potest occurrere interrupcionis currentis, ducens ad rekindling arcus et subsequentes lineae defectus.

  • Usus Contactorum: In frequentibus operationibus aperiendi et claudendi, contacti camerae extinguendi arcuum vacuum possunt consumi per erosionem arcuum. Consumptio contactorum auget resistenciam contactorum, quod potest ducere ad severum calefactionem contactorum quando currentus normalis transit, affectans operationem normalem equipmenti. Praeterea, interrupcio currentis fault, contacti non possunt sustinere currentem altum, resultante welding contactorum vel failure interrupcionis currentis.

Solutio Defectus Camerae Extinguendi Arcuum Vacuum :

Decrease Vacuum Level :

  • Detectare Level Vacuum: Utere instrumentis specialibus detectandi level vacuum, sicut testeris level vacuum, ad regulariter inspectandum level vacuum camerae extinguendi arcuum vacuum. Quod level vacuum invenitur esse infra valor specificatus, camera extinguendi arcuum vacuum debet prompte substitui.

  • Substituere Seals: Si suspectas sealing malam causare diminutionem level vacuum, inspecta et substitue seals. Substitutione seals, assecura ut utaris materialibus sealing qualitatibus altis et compatibilibus et sequaris correctos proceduras installationis ad praeventionem ulterioris leakage.

Usus Contactorum :

  • Inspectiones Regulariter: Inspecta regulariter conditionem usus contactorum per fenestras observationis vel dissecando dispositivum. Consecutim, si usus excedit limites specificatos, contacti debent prompte substitui.

  • Optimizare Parametros Operationis: Analyza causas usus contactorum, sicut an sit propter operationes frequentes vel currentem operationis excessivum. Si problema est operationes frequentes, considera optimizare strategiam reclosing reclosoris ad reducendum operationes aperiendi et claudendi inutilis. Si problema est currentem operationis excessivum, inspice conditions load lineae, ajusta settings protectionis, et evita subjecting contactorum ad impactus currentis excessivi.


Bibliotheca Documentorum Rerum
Restricted
SEC SPECIFICATIONS FOR SMART MV AUTO-RECLOSER
Other
English
Consulting
Consulting
Restricted
BREB 11kV Automatic Circuit Reclose Specification Submission Sheet
Other
English
Consulting
Consulting
Restricted
11kV Automatic Circuit Reclose Standard for Class III in Bangladesh
Other
English
Consulting
Consulting
Restricted
15 kV Pole Mount Auto Recloser Technical Specifications for Guyana Power & Light Incorporated (GPL)
Other
English
Consulting
Consulting
Restricted
15kV Switching Station requirements in Ethiopia
Other
English
Consulting
Consulting
Restricted
15kV/27kV/38kV outdoor auto break vacuum recloser brochure
Brochure
English
Consulting
Consulting
Restricted
10 to 38kV auto vacuum break recloser Catalog
Catalogue
English
Consulting
Consulting
Restricted
15kV automatic recloser technology specification
Technical Data Sheet
English
Consulting
Consulting
FAQ
Q: Quae sunt principes technologici pro circuitis interruptoribus sine SF6 gas?
A:

1. Technologia insulantis miscellae gasorum amicae ambienti
Gas miscellae CO ₂ et perfluoroketonis/nitrilis: sicut gas miscellae CO ₂/C ₅ - PFK (perfluoroketon) vel CO ₂/C ₄ - PFN (perfluoronitril). Haec gas miscellae iungunt facultatem extinguentiam arcus CO ₂ cum fortitudine dielectrica alta perfluoroketonum/nitrilorum, facientes eas substitutum SF ₆ in applicationibus altae tensionis. Exempli gratia, gas miscellae CO ₂/C ₄ - PFN iam applicatus est commercialiter in disiuncturis altae tensionis, cum performance insulantis et frangendi similari ad SF ₆, et potenti globali calefactionis (GWP) significanter reducto.
Gas miscellae aeris et perfluoroketoni: In applicationibus mediae pressionis, mixtura aeris et C ₅ - PFK uti potest medium insulantem. Per optimisationem rationis miscendae et pressionis, perficitur insulatio comparabilis SF ₆, minuendo impactum ambientem.
2. Technologia disiunctoris vacui
Cubiculum extinguentiae arcus vacui: Utilizando fortitudinem insulantis altam et celeritatem extinguentiam arcus in ambiente vacuo, substituitur functio extinguentiae arcus SF ₆. Disiunctores vacui late usi sunt in campis mediae et parvae tensionis, praesertim in scenariis cum exigentia ambientali alta. Eorum praebantur beneficia absque emissionibus gasorum calefactorum tecti et excellentia performance extinguentiae arcus, sed opus est solvere problemata sicut sigillatio vacua et materiae contactuum.
Combinatio disiunctoris vacui et insulantis gasorum: In quibusdam apparatibus switchgear mediae tensionis, disiunctores vacui utuntur elementis frangendis, combinati cum aere sicco vel nitro ut mediis insulantibus, formantes apparatum insulantem gasorum amicum ambienti (GIS) qui equilibrit perficiens insulantis et frangendi.

Q: Quid est differentia inter circuitum interruptorem vacui et circuitum interruptorem SF
A:
  1. Diversitas eorum principalis est in medio arcus extinguendi: interruptores vacui utuntur alto vacuo (10⁻⁴~10⁻⁶Pa) ad insulationem et extinctionem arcus; interruptores SF₆ confidunt in gas SF₆, quod electrona bene adsorbet ad extinguendum arcum.
  2. In adaptatione voltus: interruptores vacui conveniunt ad media et parva voltage (10kV, 35kV; nonnulli usque ad 110kV), raro supra 220kV. Interruptores SF₆ apti sunt ad altas et ultra-altas voltus (110kV~1000kV), praecipue in rete ultra-alti voltaginis.
  3. De performance: interruptores vacui celeriter arcus extinguunt (<10ms), habent capacitatem interrumpendi 63kA~125kA, et conveniunt ad frequentem usum (sicut in distributione electricitatis) cum longa vita (>10,000 cyclus). Interruptores SF₆ excellunt in stabiliter magnas et inductivas currentes interrumpendo, sed minus frequenter operantur, post extinctionem requirunt tempus ad restitutionem insulationis.
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
  • Quid est Differentia Inter Transformatores Rectificatores et Transformatores Potentiae?
    Quid est transformator rectificans?"Conversio potentiae" est terminus generalis qui conversionem, inversionem et conversionem frequentiae comprehendit, inter quas conversio praecipue usitatissima est. Apparatus rectificans convertit potentiam AC input in DC output per rectificationem et filtrationem. Transformator rectificans servit ut transformator alimentationis pro talibus apparatibus rectificantibus. In applicationibus industrialibus, plerumque alimenta DC obtinentur per combinandum transfor
    01/29/2026

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe